ICC California UST Service Technician Questions And 100% Correct Answers UDC was required at time of installation for all systems installed after? January 1, 2000 July 1, 2005, service techs shall possess or work under someone who has a current certification indicating he or she has passed the? ICC UST Service Technician Exam ICC cert must be renewed every? 24 months Service techs must possess or be employed by a person who has the appropriate contractor's license unless? The individual has a tank testing license Service tech is defined as any individual who? Tests UST monitoring equipment, trouble shoots UST systems, and or installs UST monitoring equipment. If the manufacture training no longer exist, the local agency may? Approve comparable alternate training .UST includes? Tank and connected piping What is considered a UST? A petroleum storage tank. What UST system meets the requirements for secondary containment? Doubled wall tanks Title 23; The following piping components if installed after July 1, 1987 must have secondary containment. Pressured product piping Tanks installed after July 1, 2003 are considered "pipe" Pressured product piping and below ground vapor recovery. UDC Under dispenser containment was required for all existing UST systems by December 31, 2003 Stage 1 vapor recovery System for exchanging gas vapors in a storage tank and product in a fuel delivery truck An approved method for non-visual monitoring for existing UST systems. Statistical Inventory Reconciliation (SIR) ATG must be capable for detecting a release of? 0.2 gallons per hour What is no longer an approved method for non-visual monitoring on existing UST systems?Manual inventory reconciliation. Automatic line leak detectors installed on underground piping with secondary containment shall be capable of detecting a leak of? 3 gallons per hour at 10 psi How often should ATG be programmed to test the tank? At least monthly According to PEI RP 300, a combustible gas can be used to? Detect vapor leaks in a vapor recovery system. According to PEI RP 300, a written scope of work for vapor recovery installation should include? Construction plans Positive shut off overfill protection device must stop the flow of fuel when the tank is no more then? 95% full VR 201-A According to, what could cause a nozzle shut off mechanism or malfunction? Rely filter seal damage According to VR 201-A, breakaway reconnection should be? Logged in GDF log According to PEI RP 300 what is an INCORRECT method of documenting piping location? Drawing a diagram on the inside cover of vapor recovery equipment manualAccording to PEI RP 300 as built drawing or pictures of the underground pipping and other components shall be_________. maintained as long as UST is in service. According to EO VR 101-E maintenance records are required to include what? Name and Designated UST Operator. The Phil-Tite EVR Phase 1 system require that vapor vent pipes at any UST system be Used with no more than 3 p/v valves Healy 900 nozzle, which one of the following test should be conducted after installing a new spout assembly according to EO VR 2010? Nozzle dispensing shut off test According to Healy EO VR 201-A, who is responsible to maintain a vapor recovery record?

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

ICC California UST Service Technician Questions And 100%
Correct Answers 2025-2026


UDC was required at time of installation for all systems installed after?

January 1, 2000



July 1, 2005, service techs shall possess or work under someone who has a current
certification indicating he or she has passed the?

ICC UST Service Technician Exam



ICC cert must be renewed every?

24 months



Service techs must possess or be employed by a person who has the appropriate
contractor's license unless?



The individual has a tank testing license




Service tech is defined as any individual who?

Tests UST monitoring equipment, trouble shoots UST systems, and or installs UST
monitoring equipment.




If the manufacture training no longer exist, the local agency may?

Approve comparable alternate training .

,UST includes?

Tank and connected piping



What is considered a UST?

A petroleum storage tank.



What UST system meets the requirements for secondary containment?

Doubled wall tanks




Title 23; The following piping components if installed after July 1, 1987 must have
secondary containment.

Pressured product piping

Tanks installed after July 1, 2003 are considered "pipe"

Pressured product piping and below ground vapor recovery.

UDC Under dispenser containment was required for all existing UST systems by

December 31, 2003

Stage 1 vapor recovery System for exchanging gas vapors in a storage tank and
product in a fuel delivery truck




An approved method for non-visual monitoring for existing UST systems.

Statistical Inventory Reconciliation (SIR)

ATG must be capable for detecting a release of?

0.2 gallons per hour

What is no longer an approved method for non-visual monitoring on existing UST
systems?

,Manual inventory reconciliation.

Automatic line leak detectors installed on underground piping with secondary
containment shall be capable of detecting a leak of?

3 gallons per hour at 10 psi




How often should ATG be programmed to test the tank?

At least monthly



According to PEI RP 300, a combustible gas can be used to?

Detect vapor leaks in a vapor recovery system.



According to PEI RP 300, a written scope of work for vapor recovery installation should
include?

Construction plans



Positive shut off overfill protection device must stop the flow of fuel when the tank is no
more then?

95% full




VR 201-A According to, what could cause a nozzle shut off mechanism or malfunction?

Rely filter seal damage

According to VR 201-A, breakaway reconnection should be?

Logged in GDF log

According to PEI RP 300 what is an INCORRECT method of documenting piping
location?

Drawing a diagram on the inside cover of vapor recovery equipment manual

, According to PEI RP 300 as built drawing or pictures of the underground pipping and
other components shall be_________.

maintained as long as UST is in service.



According to EO VR 101-E maintenance records are required to include what?

Name and Designated UST Operator.



The Phil-Tite EVR Phase 1 system require that vapor vent pipes at any UST system be

Used with no more than 3 p/v valves




Healy 900 nozzle, which one of the following test should be conducted after installing a
new spout assembly according to EO VR 2010?



Nozzle dispensing shut off test



According to Healy EO VR 201-A, who is responsible to maintain a vapor recovery
record?



Gasoline dispensing facility operator(GDF)



A public drinking well requires enhanced leak detection test within how many feet?



1000 feet



Name the components of the Fire Triangle.

Fuel, Heat/Ignition Source, Oxygen

Geschreven voor

Vak

Documentinformatie

Geüpload op
31 mei 2025
Aantal pagina's
42
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$12.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
NurseAdvocate chamberlain College of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
497
Lid sinds
2 jaar
Aantal volgers
77
Documenten
12046
Laatst verkocht
5 uur geleden
NURSE ADVOCATE

I have solutions for following subjects: Nursing, Business, Accounting, statistics, chemistry, Biology and all other subjects. Nursing Being my main profession line, I have essential guides that are Almost A+ graded, I am a very friendly person: If you would not agreed with my solutions I am ready for refund

4.6

239 beoordelingen

5
193
4
14
3
15
2
6
1
11

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen