2024/2025

1 | P a g e C o p y r i g h t © 2 0 2 5 T H E B R I G H T A L L R I G H T S R E S E R V E D HEATING SERVICE EXAM 2025 QUESTIONS AND ANSWERS On a low pressure residential steam boiler the release device opens at? - ANS 15 pounds If too much primary air is used the flame will - ANS Lift off the burner What operates the heat anticipator in a low voltage thermostat - ANS 24 volts a/c A limit control is located where in the electrical circuit - ANS Either the 24 or 120 V circuit What is the usual oil pressure at the nozzle in a high pressure gun type oil burner - ANS 100 PSIG What license is required to perform a CSD-1 on a boiler that has an input rating of 1.7 MBTU - ANS Mechanical contractor category 6 A psychrometer meter is what ? - ANS A Hygrometer consisting of a wet-bulb and dry-bulb Thermometer, The difference in the two readings used to determine the atmospheric humidity A psychrometric chart is a - ANS Chart where the various property of air is plotted Combustion is what type of process - ANS chemical What percentage of oxygen is in the air - ANS 21% 2 | P a g e C o p y r i g h t © 2 0 2 5 T H E B R I G H T A L L R I G H T S R E S E R V E D A hand shut off valve in a gas line is used to turn gas on and off to - ANS A burner and pilot CGV is the abbreviation for - ANS Combustion gas valve The maximum safety drop out time for a thermocouple is - ANS Three minutes The bimetallic Strip of metal in a thermostat is made of copper and ? - ANS Invar What is the light sensitive material used in a cad cell - ANS Cadmium sulphide What is the resistance measured in a cad cell in the absence of light - ANS 100,000 When operating a fuel oil furnace with a one pipe system what needs to take place at the fuel pump ? - ANS Bypass plug should not be installed A gas drip leg must ? - ANS Not be smaller in diameter than the pipe which it connects All boilers shall have the portable water protected with - ANS A backflow preventer Compared to national gas with the same BTU rating, the orifice opening in an LP gas fire furnace is ? - ANS Smaller A thermostat that cycles too often or not enough indicates - ANS Improper heat anticipator setting The pressure regulator on a

Show more Read less
Institution
HEATING SERVICE
Course
HEATING SERVICE

Content preview

HEATING SERVICE EXAM 2025
QUESTIONS AND ANSWERS


On a low pressure residential steam boiler the release device opens at? - ANS 15 pounds


If too much primary air is used the flame will - ANS Lift off the burner


What operates the heat anticipator in a low voltage thermostat - ANS 24 volts a/c


A limit control is located where in the electrical circuit - ANS Either the 24 or 120 V circuit


What is the usual oil pressure at the nozzle in a high pressure gun type oil burner - ANS 100
PSIG


What license is required to perform a CSD-1 on a boiler that has an input rating of 1.7 MBTU -
ANS Mechanical contractor category 6


A psychrometer meter is what ? - ANS A Hygrometer consisting of a wet-bulb and dry-bulb
Thermometer, The difference in the two readings used to determine the atmospheric humidity


A psychrometric chart is a - ANS Chart where the various property of air is plotted


Combustion is what type of process - ANS chemical


What percentage of oxygen is in the air - ANS 21%

1|P a g e C o p y r i g h t © 2 0 2 5 T H E B R I G H T A L L R I G H T S R E S E R V E D

, A hand shut off valve in a gas line is used to turn gas on and off to - ANS A burner and pilot


CGV is the abbreviation for - ANS Combustion gas valve


The maximum safety drop out time for a thermocouple is - ANS Three minutes


The bimetallic Strip of metal in a thermostat is made of copper and ? - ANS Invar


What is the light sensitive material used in a cad cell - ANS Cadmium sulphide


What is the resistance measured in a cad cell in the absence of light - ANS 100,000


When operating a fuel oil furnace with a one pipe system what needs to take place at the fuel
pump ? - ANS Bypass plug should not be installed


A gas drip leg must ? - ANS Not be smaller in diameter than the pipe which it connects


All boilers shall have the portable water protected with - ANS A backflow preventer


Compared to national gas with the same BTU rating, the orifice opening in an LP gas fire furnace
is ? - ANS Smaller


A thermostat that cycles too often or not enough indicates - ANS Improper heat anticipator
setting


The pressure regulator on a LP gas system is set at - ANS 11.0 w.c


A fast acting type of gas valve is the _________ valve ? - ANS Solenoid
2|P a g e C o p y r i g h t © 2 0 2 5 T H E B R I G H T A L L R I G H T S R E S E R V E D

Written for

Institution
HEATING SERVICE
Course
HEATING SERVICE

Document information

Uploaded on
June 2, 2025
Number of pages
8
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$11.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Thebright Florida State University
Follow You need to be logged in order to follow users or courses
Sold
228
Member since
1 year
Number of followers
6
Documents
13787
Last sold
1 day ago
Topscore Emporium.

On this page, you find verified, updated and accurate documents and package deals.

3.6

42 reviews

5
15
4
10
3
9
2
3
1
5

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions