The regulations to enforce compliance of underground storage tank systems in the state are found in?
tz
sh
Sp
ne
a.) Code of Federal Regulations, 40 CFR Part 281
la
b.) California Code of Regulations, Title 23, Chapter 16
sh
Sp
c.) Code of Federal Regulations, 40 CFR Part 280
ne
d.) California Code of Regulations, Title 23, Chapter 17 - ANSWER--b.) California Code of Regulations;
la
Title 23, Chapter 16
tz
sh
Sp
ne
By definition an "underground storage tank system" includes
la
sh
a.) The tank, all connected piping and dispensers
Sp
ne
b.) The tank, all connected piping, ancillary equipment and containment system
la
c.) Only the tank
tz
sh
d.) Only tanks totally beneath the surface of the ground - ANSWER--b.) The tank, all connected piping,
Sp
ancillary equipment and containment system
ne
la
(H&SC, Sec 25281(z))
sh
Sp
ne
la
Under-dispenser containment was required for all UST systems by ___________.
tz
sh
Sp
ne
a.) December 31, 2003
la
b.) July 1, 1987
sh
c.) January 1, 1984
Sp
ne
d.) January 1, 2000 - ANSWER--a.) December 31, 2003
a
tz
l
sh
CCR Title 23, Sec 2636(g)(C)
Sp
ne
la
sh
Sp
la
Sp
, ne
UST Questions and Answers to Study for 2024 Final
sh
Exam/100% Verified
ne
la
According to California Law, UST systems installed after July 1, 2003, require a one-time ELD test to
tz
ensure that the tank is product tight...
sh
Sp
ne
la
a.) If the tank is located within one (1) mile of a public drinking water well
sh
b.) If the tank is located within 1000 feet of a public drinking water well
Sp
ne
c.) Unless the tank is equipped with secondary containment
la
d.) In all cases - ANSWER--For ALL tanks before use (H&SC 25290.2 (I))
tz
sh
d.) In all cases
Sp
ne
la
H&SC, Sec 25290.2(i)
sh
Sp
ne
The written report submitted to the local agency after an unauthorized release is required to include the
following except:
la
tz
sh
Sp
a.) Description of actions taken to stop the release
ne
la
b.) Cause of the release
c.) Method of disposal of released product
sh
Sp
ne
d.) Date on which the release was discovered - ANSWER--b.) Cause of the release
la
tz
CCR Title 23, Sec 2652(c) sh
Sp
ne
la
An unauthorized release which does not escape from secondary containment only requires a record on
the operator's monitoring reports provided:
sh
Sp
ne
A. It did not increase the hazard of fire
a
tz
B. It did not cause any deterioration of the secondary containment
l
sh
Sp
C. It was cleaned up within 8 hours of detection
ne
D. All of the above - ANSWER--D. All of the above
la
sh
Sp
la
Sp
, ne
UST Questions and Answers to Study for 2024 Final
sh
Exam/100% Verified
ne
la
tz
sh
Sp
H&SC, Sec 25294
ne
la
The annual monitoring certification may be performed by:
sh
Sp
ne
A. A person possessing the appropriate contractors licenses
la
B. An individual trained and certified by the manufacturer of the monitoring equipment
tz
sh
Sp
C. A designated UST operator
ne
D. A person who meets the requirements of both a and b - ANSWER--D. A person who meets the
la
requirements of both a and b
sh
Sp
ne
CCR Title 23, Sec 2715(i)
la
tz
sh
The following is true of secondary containment testing, EXCEPT:
Sp
ne
la
a.) Must be tested every 24 months
sh
b.) Must be tested every 36 months
Sp
ne
c.) Results must be submitted to the local agency within 30 days of testing
la
d.) Local agency must be notified 48 hours prior to testing - ANSWER--a.) Must be tested every 24
tz
months sh
Sp
ne
la
CCR Title 23, Sec 2637(a)
sh
Sp
ne
Records of cathodic protection system maintenance must be kept on file for ______________.
a
tz
l
sh
a.) 10 years
Sp
ne
b.) 1.5 years
la
c.) 3 years
sh
Sp
la
Sp
, ne
UST Questions and Answers to Study for 2024 Final
sh
Exam/100% Verified
ne
la
d.) 6.5 years - ANSWER--d.) 6.5 years
tz
sh
Sp
ne
CCR Title 23, Sec 2712(b)
la
sh
Sp
Impressed current cathodic protection systems shall be inspected no less than every ___________ to
ne
ensure that they are in proper working order:
la
tz
sh
a.) 60 days
Sp
ne
b.) 90 days
la
c.) 30 days
sh
d.) 120 days - ANSWER--a.) 60 days
Sp
ne
la
CCR Title 23, Sec 2635(a)(2)
tz
sh
Sp
ne
Monthly monitoring data must be kept on file for _________________.
la
sh
a.) 3 years
Sp
ne
b.) 6.5 years
la
c.) 5 years
tz
sh
Sp
d.) For the life of the UST system - ANSWER--a.) 3 years
ne
la
CCR Title 23, Sec 2712(b)
sh
Sp
ne
By December 22, 1998, all automatic line leak detectors installed on single-walled pressurized piping
a
must be capable of:
tz
l
sh
Sp
ne
a.) Restricting product flow
la
b.) Triggering an audible and visual alarm
sh
Sp
la
Sp