Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

Electricity Test Exam Questions And Answers Verified 100% Correct

Rating
-
Sold
-
Pages
11
Grade
A+
Uploaded on
07-06-2025
Written in
2024/2025

Electricity Test Exam Questions And Answers Verified 100% Correct A system that is connected to establish electrical continuity and conductivity is considered to be which of the following? - ANSWER Bonded If installed and routed on the outside of a raceway, the length of the equipment bonding jumper shall not exceed how many feet? - ANSWER 6 feet What is the minimum size of the aluminum equipment grounding conductor where the overcurrent protection ahead of a branch circuit or feeder is sized at 600 amperes? - ANSWER 2/0 The portion of a grounding electrode conductor in a dc system that is connected to a rod or pipe shall NOT be required to be larger than which of the following? - ANSWER 6 awg copper Where are flat cable assemblies permitted to be installed? - ANSWER In exposed locations In which application is the installation of NM cable permitted? - ANSWER Type 3 construction Disregarding exceptions, conductors used for direct burial applications shall be shielded if rated above which of the following? - ANSWER 2000 volts In which application is the installation of UF cable permitted? - ANSWER In photovoltaic systems Where is AC cable NOT permitted to be used? - ANSWER In damp location Disregarding exceptions, what is the minimum size copper-clad aluminum underground service conductor permitted? - ANSWER # 6 awg What is the maximum spacing for supports of 10 AWG copper conductors located in a vertical raceway? - ANSWER 100 feet Unless otherwise provided, MC cables shall be secured at intervals not exceeding which of the following? - ANSWER 6 feet Which type of service-entrance cable has a flame-resistant and moisture resistant covering? - ANSWER Type SE What is the minimum size copper conductor permitted for use for a 6,000 volt service? - ANSWER 6 awg How many quarter bends are allowed in IMT between pull points? - ANSWER 4 A fitting is a part of a wiring system that is intended primarily to perform which type of function? - ANSWER Mechanical What is the maximum number of 12 AWG conductors that can be used in a 4" x 1-1/2" square box? - ANSWER 9 In which application is red brass rigid metal conduit permitted? - ANSWER Direct burial The length of the pull box shall not be less than how many times the outside diameter, over sheath, of the largest shielded or lead-covered conductor or cable entering the box? - ANSWER 48 times When installed in the same cable tray, cables operating at over 600 volts shall be of which type? - ANSWER MC The combined cross-sectional area of all conductors or cables shall not exceed what percentage of the interior cross sectional area of the underfloor raceway? - ANSWER 40% The conductors, including splices and taps, shall not fill the wireway to more than what percentage of its area? - ANSWER 75% In which locations are the installation of flexible metal conduit permitted? - ANSWER Concealed location What is the minimum size solid conductor permitted to be installed in a raceway? - ANSWER # 8 What is the maximum distance that the emergency controls for an attended self-service motor fuel dispensing facility shall be located from the dispensers? - ANSWER 100 feet For pool equipment, the disconnecting means for all ungrounded conductors shall be readily accessible and within sight from its equipment and shall be located a minimum of how many feet horizontally from the inside walls of a pool? - ANSWER 5 feet A panelboard for a mobile home shall be rated not less than which of the following? - ANSWER 50 amps Signs and outline lighting system equipment for wet location use, other than listed watertight type, shall be weatherproof and have drain holes not larger than - ANSWER 1/2 inch What is the maximum weight of a luminaire that can be supported by the screw shell of a lampholder? - ANSWER 6 pounds Lamp tie wires, mounting screws, clips, and decorative bands on glass shall not be required to be grounded if spaced at least how far from the lamp terminals? - ANSWER 1 1/2 inches Snap switches directly connected to aluminum conductors shall be listed

Show more Read less
Institution
Electricity
Course
Electricity

Content preview

Electricity Test Exam Questions And Answers
Verified 100% Correct

A system that is connected to establish electrical continuity and
conductivity is considered to be which of the following? - ANSWER
Bonded

If installed and routed on the outside of a raceway, the length of the
equipment bonding jumper shall not exceed how many feet? - ANSWER 6
feet

What is the minimum size of the aluminum equipment grounding conductor
where the overcurrent protection ahead of a branch circuit or feeder is
sized at 600 amperes? - ANSWER 2/0

The portion of a grounding electrode conductor in a dc system that is
connected to a rod or pipe shall NOT be required to be larger than which of
the following? - ANSWER 6 awg copper

Where are flat cable assemblies permitted to be installed? - ANSWER In
exposed locations

In which application is the installation of NM cable permitted? - ANSWER
Type 3 construction

Disregarding exceptions, conductors used for direct burial applications
shall be shielded if rated above which of the following? - ANSWER 2000
volts

In which application is the installation of UF cable permitted? - ANSWER
In photovoltaic systems

Where is AC cable NOT permitted to be used? - ANSWER In damp
location

Disregarding exceptions, what is the minimum size copper-clad aluminum

, underground service conductor permitted? - ANSWER # 6 awg

What is the maximum spacing for supports of 10 AWG copper conductors
located in a vertical raceway? - ANSWER 100 feet

Unless otherwise provided, MC cables shall be secured at intervals not
exceeding which of the following? - ANSWER 6 feet

Which type of service-entrance cable has a flame-resistant and moisture
resistant covering? - ANSWER Type SE

What is the minimum size copper conductor permitted for use for a 6,000
volt service? - ANSWER 6 awg

How many quarter bends are allowed in IMT between pull points? -
ANSWER 4

A fitting is a part of a wiring system that is intended primarily to perform
which type of function? - ANSWER Mechanical

What is the maximum number of 12 AWG conductors that can be used in
a 4" x 1-1/2" square box? - ANSWER 9

In which application is red brass rigid metal conduit permitted? - ANSWER
Direct burial

The length of the pull box shall not be less than how many times the
outside diameter, over sheath, of the largest shielded or lead-covered
conductor or cable entering the box? - ANSWER 48 times

When installed in the same cable tray, cables operating at over 600 volts
shall be of which type? - ANSWER MC

The combined cross-sectional area of all conductors or cables shall not
exceed what percentage of the interior cross sectional area of the
underfloor raceway? - ANSWER 40%

Written for

Institution
Electricity
Course
Electricity

Document information

Uploaded on
June 7, 2025
Number of pages
11
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$11.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TopGradeGuru Teachme2-tutor
Follow You need to be logged in order to follow users or courses
Sold
15
Member since
1 year
Number of followers
0
Documents
2395
Last sold
2 months ago
GRADEHUB

We provide access to a wide range of professionally curated exams for students and educators. It offers high-quality, up-to-date assessment materials tailored to various subjects and academic levels. With instant downloads and affordable pricing, it\'s the go-to resource for exam preparation and academic success.

1.5

2 reviews

5
0
4
0
3
0
2
1
1
1

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions