NICET FIRE ALARMS EXAM QUESTIONS
WITH 100% CORRECT ANSWERS
What is the primary purpose of automatic trouble resound? - Answer-to remind the
building owners

The max room area that may be covered by a ceiling mounted strobe should be no
more than: - Answer-50 feet x 50 feet, single ceiling mounted strobe

A Master Box is publicly accessible. - Answer-TRUE. It may also be operated by a
remote initiating device.

You can verify the operability of all your controlled mechanical equipment through: -
Answer-periodic testing

Building codes usually call for the installation of voice evacuation systems: - Answer-
TRUE

17.14.8.3* Manual pull stations are required to be red in color. - Answer-TRUE

Ion detectors can detect a flaming fire faster. - Answer-TRUE; flaming fire (not
smoldering)

Photo-electric detectors cannot detect a smoldering fire fast enough. - Answer-FASLE;
can detect smoldering fire faster (not flaming)

NFPA 72 addresses signaling systems used for fire hazards and more. - Answer-TRUE

17.5.3.1 The definition of total coverage covers: - Answer-rooms, halls, storage areas,
basements, attics, lofts, all

When the ceiling height exceeds _____ the heat detector spacing will have to be
reduced. - Answer-10 feet; heat detector spacing needs to be reduced

A fire plume has a shape which looks like: - Answer-inverted cone shape

Smoldering fire does not have flame or heat to push combustion to the ceiling. -
Answer-TRUE

Fire authorities almost always refer all detector spacing considerations to the
requirements of: - Answer-NFPA 72 & engineering judgement

, For infared/ultraviolet detectors to work, what must be available? - Answer-unobstructed
view

Fixed temperature spot-type detectors are most suitable for: 3.3.66.7* - Answer-
enclosed areas

A four-wire smoke detector has how many distinct circuits? - Answer-two (2)

With a four-wire smoke detector, it is the _____ circuit that provides resettable power. -
Answer-first circuit

An initiating device originates transmission in a change of state condition. - Answer-
TRUE

A line type detector can perform detection which is: - Answer-continuous along a path

Level ceilings have a slope of less than _____ per foot. - Answer-1.5 or 1 1/2" inches
per foot

It is the NFPA 72 that specifies what type of equipment should be used. - Answer-
FALSE

In codes, the word __________ often indicates a mandatory equipment. - Answer-shall

What determines the fire alarm requirements? - Answer-locally enforced building code

Most codes determine the fire alarm sprinkler requirements base on: - Answer-
occupancy classification of the involved building

In a conventional fire alarm systen, it is the number of initiating zones that defines how
large the system can be. - Answer-TRUE

How does a dry contact device work? - Answer-dry contacts will close causing an alarm;
usually used on conventional systems (zone 1, zone 2)

Which of the following are dry devices? pull stations, heat detectors, four-wire smoke
detectors, flow switches - Answer-all; pull stations, heat detectors, four-wire smoke
detectors, flow switches

Powered devices must be listed for compatibility. - Answer-TRUE, they use voltage from
the control panel

Powered devices always operate on a "GO/NO GO" manner only. - Answer-TRUE

It is okay to use smoke detectors that are battery operated in a residential building. -
Answer-TRUE

Geschreven voor

Instelling
NICET FIRE ALARMS
Vak
NICET FIRE ALARMS

Documentinformatie

Geüpload op
9 juni 2025
Aantal pagina's
7
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$15.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
victoryguide stuvia
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
27
Lid sinds
1 jaar
Aantal volgers
1
Documenten
3005
Laatst verkocht
1 maand geleden

3.7

10 beoordelingen

5
5
4
0
3
3
2
1
1
1

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen