NERC EXAM, TEST, PRACTICE EXAM AND STUDY GUIDE LATEST ACTUAL EXAM 200 QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES (VERIFIED ANSWERS) |ALREADY GRADED A+ A 50 MVA rated transformer has 30 MW of load. How many MVARs can flow through the transformer without exceeding the rating? A. 50 MVAR B. 40 MVAR C. 30 MVAR D. 80 MVAR - ANSWER-B. 40 MVAR A balancing authority is responsible for load - interchange - generation balance, which calculated value reflects that balance? A. Frequency B. System Lambda C. Operating reserves D. ACE - ANSWER-D. ACE A transmission line has a net VAR load of 25 MVAR into the line resembles which of these statements? A. The line is equivalent to an inductor B. The line is transferring the optimum load C. The line is nearing voltage collapse D. The line is equivalent to a capacitor - ANSWER-A. The line is equivalent to an inductor Frequency of the power system is mainly determined by which factor? A. Load and generation balance in your balancing authority area B. Load and generation balance in the interconnection C. Generation power flowing on the transmission lines D. Load requirement of each power system - ANSWER-B. Load and generation balance in the interconnection Generator reactive power output increases dynamically under which condition? A. Low voltage B. High voltage C. Transmission line trip D. Energy and capacity deficiency - ANSWER-A. Low voltage If interconnection frequency is 59.95 Hz, how do balancing authorities support interconnection frequency? A. Remain at current MW output level B. Increasing MW output C. Decreasing MW output D. Increasing excitation on the field windings - ANSWER-B. Increasing MW output In a power system which type of power is especially critical to support heavily loaded transmission lines and to have dynamic reserves in preparation for contingency? A. Reactive power B. Real power C. Power flow D. Apparent power - ANSWER-A. Reactive power Reactive power is needed to support which type of load? A. Capacitive B. Resistive C. Impedance D. Inductive - ANSWER-D. Inductive System inertia is the ability of a power system to: A. Increase the speed of the rotation of the units resulting in an increase in system frequency B. Decrease the speed of the rotation of the units resulting in a decrease in system frequency C. Oppose changes in frequency due to resistance provided by kinetic energy of the rotating masses D. All of the above - ANSWER-D. All of the above The ACE equation must include which metered data in addition to the dynamic schedules, pseudo ties, actual frequency?

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

NERC EXAM, TEST, PRACTICE EXAM AND STUDY
GUIDE LATEST 2023-2024 ACTUAL EXAM 200
QUESTIONS AND CORRECT DETAILED ANSWERS
WITH RATIONALES (VERIFIED ANSWERS) |ALREADY
GRADED A+
A 50 MVA rated transformer has 30 MW of load. How many MVARs can flow through the transformer
without exceeding the rating?

A. 50 MVAR

B. 40 MVAR

C. 30 MVAR

D. 80 MVAR - ANSWER-B. 40 MVAR



A balancing authority is responsible for load - interchange - generation balance, which calculated value
reflects that balance?

A. Frequency

B. System Lambda

C. Operating reserves

D. ACE - ANSWER-D. ACE



A transmission line has a net VAR load of 25 MVAR into the line resembles which of these statements?

A. The line is equivalent to an inductor

B. The line is transferring the optimum load

C. The line is nearing voltage collapse

D. The line is equivalent to a capacitor - ANSWER-A. The line is equivalent to an inductor



Frequency of the power system is mainly determined by which factor?

A. Load and generation balance in your balancing authority area

B. Load and generation balance in the interconnection

C. Generation power flowing on the transmission lines

,D. Load requirement of each power system - ANSWER-B. Load and generation balance in the
interconnection



Generator reactive power output increases dynamically under which condition?

A. Low voltage

B. High voltage

C. Transmission line trip

D. Energy and capacity deficiency - ANSWER-A. Low voltage



If interconnection frequency is 59.95 Hz, how do balancing authorities support interconnection
frequency?

A. Remain at current MW output level

B. Increasing MW output

C. Decreasing MW output

D. Increasing excitation on the field windings - ANSWER-B. Increasing MW output



In a power system which type of power is especially critical to support heavily loaded transmission lines
and to have dynamic reserves in preparation for contingency?

A. Reactive power

B. Real power

C. Power flow

D. Apparent power - ANSWER-A. Reactive power



Reactive power is needed to support which type of load?

A. Capacitive

B. Resistive

C. Impedance

D. Inductive - ANSWER-D. Inductive



System inertia is the ability of a power system to:

, A. Increase the speed of the rotation of the units resulting in an increase in system frequency

B. Decrease the speed of the rotation of the units resulting in a decrease in system frequency

C. Oppose changes in frequency due to resistance provided by kinetic energy of the rotating masses

D. All of the above - ANSWER-D. All of the above



The ACE equation must include which metered data in addition to the dynamic schedules, pseudo ties,
actual frequency?

A. Generation

B. Transformers

C. Tie Lines

D. Communications - ANSWER-C. Tie Lines



The load on a power transformer is 40 MW and 30 MVAR. What is the transformer's power factor?

A. 0.80

B. 0.70

C. 0.60

D. 0.50 - ANSWER-A. 0.80



The primary cause of low voltage is:

A. VAR losses associated with heavy power transfers

B. Insufficient generation

C. Insufficient transmission capacity

D. Insufficient shunt reactors in service - ANSWER-A. VAR losses associated with heavy power transfers



What causes real power losses on the bulk power system?

A. Current flow causing heating

B. Load that is not online

C. High cost generation

D. Inefficient heat rates - ANSWER-A. Current flow causing heating

Geschreven voor

Vak

Documentinformatie

Geüpload op
9 juni 2025
Aantal pagina's
21
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$14.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
NurseAdvocate chamberlain College of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
499
Lid sinds
2 jaar
Aantal volgers
77
Documenten
12043
Laatst verkocht
2 dagen geleden
NURSE ADVOCATE

I have solutions for following subjects: Nursing, Business, Accounting, statistics, chemistry, Biology and all other subjects. Nursing Being my main profession line, I have essential guides that are Almost A+ graded, I am a very friendly person: If you would not agreed with my solutions I am ready for refund

4.5

238 beoordelingen

5
191
4
14
3
16
2
6
1
11

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen