CNIM TEST EXAM|| CNIM EXAM ALL QUESTIONS AND CORRECT ANSWERS ALREADY GRADED A+|| LATEST UPDATE 2024 WITH VERIFIED SOLUTIONS|| COMPLETE GUIDE ASSURED PASS!!! Which of the following is a reason why a "false-negative" could occur? - ANSWER: The lesion occurs in a structure not involved in the pathway being monitored The amplitude of the cortical response to posterior tibial SEP stimulation is at least 80% attenuated by - ANSWER: stimulation rates of 15 per second or higher In a patient with hematocrit below 10%, the SSEP waveforms will - ANSWER: increase in latency and decrease in amplitude It is important to begin monitoring EEG early during a carotid endarterectomy - ANSWER: to record the EEG before anesthesia and after induction for comparison during the case With a sampling rate of 10 kHz the shortest sine wave resolved would be - ANSWER: 0.2 msec Which of the following are acceptable filter settings for recording BAEPs: - ANSWER: 100 - 2500 Hz Evoked potential systems must be calibrated a MINIMUM of once every: - ANSWER: Six months Spinal cord evoked potentials are best recorded using a low-frequency filter setting of 100 Hz. This setting is preferred because, relative to cortical somatosensory evoked potentials, spinal cord potentials are: - ANSWER: of relatively short duration Cathode - ANSWER: Negative pole or block dot on the bar electrode Bipolar electrodes are used for localization of: - ANSWER: Signals via phase reversal Loss of BAEPs following drilling of the internal auditory canal is most likely due to: - ANSWER: Disruption of the cochlear blood supply What electrode should be used for facial nerve CMAP recording? - ANSWER: Surface Subdermal needle electrodes must be inserted symmetrically over homologous brain areas to avoid: - ANSWER: artificial amplitude asymmetries If the ear canal is occluded, you may expect: - ANSWER: Prolongation of all wave latencies If unavoidable muscle artifact is present in the BAEP you can change the locut filter to: - ANSWER: 200 Hz Which of the following is effective at the lowest concentration? - ANSWER: Isoflurane Epidural electrodes should be placed: - ANSWER: Above the dura For peroneal nerve stimulation, the ground should be placed on: - ANSWER: The thigh Which of the following peaks will be most affected by Desflurane? - ANSWER: P100 An optimal for BAEP's is: - ANSWER: 31 Hz Which montage would you use to confirm a change in the CPz-Fpz cortical response to PTN Stim ? - ANSWER: CPi-CPz A major advantage of digital filters over analog filters is: - ANSWER: They impose no phase effects on the recorded signal Which of electrode is regarded as an effective stimulator during facial nerve recordings: - ANSWER: Bipolar concentric EMG needle Which time constant of a locut filter would be most effective for cutting out low frequency noise from your signal? - ANSWER: 10 ms The input impedance of a differential amplifier should be: - ANSWER: At least 100,000,000 ohms What will be the frequency of a signal if in a 30 msec sweep the interval between each cycle of the signal is 0.03 msec? - ANSWER: 33 KHz

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

1|Page



CNIM TEST EXAM|| CNIM EXAM ALL QUESTIONS
AND CORRECT ANSWERS ALREADY GRADED
A+|| LATEST UPDATE 2024 WITH VERIFIED
SOLUTIONS|| COMPLETE GUIDE ASSURED PASS!!!
Which of the following is a reason why a "false-negative" could occur? -
ANSWER: The lesion occurs in a structure not involved in the pathway being
monitored


The amplitude of the cortical response to posterior tibial SEP stimulation is at least
80% attenuated by - ANSWER: stimulation rates of 15 per second or higher


In a patient with hematocrit below 10%, the SSEP waveforms will - ANSWER:
increase in latency and decrease in amplitude


It is important to begin monitoring EEG early during a carotid endarterectomy -
ANSWER: to record the EEG before anesthesia and after induction for
comparison during the case


With a sampling rate of 10 kHz the shortest sine wave resolved would be -
ANSWER: 0.2 msec


Which of the following are acceptable filter settings for recording BAEPs: -
ANSWER: 100 - 2500 Hz


Evoked potential systems must be calibrated a MINIMUM of once every: -
ANSWER: Six months

,2|Page


Spinal cord evoked potentials are best recorded using a low-frequency filter setting
of 100 Hz. This setting is preferred because, relative to cortical somatosensory
evoked potentials, spinal cord potentials are: - ANSWER: of relatively short
duration


Cathode - ANSWER: Negative pole or block dot on the bar electrode


Bipolar electrodes are used for localization of: - ANSWER: Signals via phase
reversal


Loss of BAEPs following drilling of the internal auditory canal is most likely due
to: - ANSWER: Disruption of the cochlear blood supply


What electrode should be used for facial nerve CMAP recording? - ANSWER:
Surface


Subdermal needle electrodes must be inserted symmetrically over homologous
brain areas to avoid: - ANSWER: artificial amplitude asymmetries


If the ear canal is occluded, you may expect: - ANSWER: Prolongation of all
wave latencies


If unavoidable muscle artifact is present in the BAEP you can change the locut
filter to: - ANSWER: 200 Hz


Which of the following is effective at the lowest concentration? - ANSWER:
Isoflurane


Epidural electrodes should be placed: - ANSWER: Above the dura

,3|Page




For peroneal nerve stimulation, the ground should be placed on: - ANSWER: The
thigh


Which of the following peaks will be most affected by Desflurane? - ANSWER:
P100


An optimal rep.rate for BAEP's is: - ANSWER: 31 Hz


Which montage would you use to confirm a change in the CPz-Fpz cortical
response to PTN Stim ? - ANSWER: CPi-CPz


A major advantage of digital filters over analog filters is: - ANSWER: They
impose no phase effects on the recorded signal


Which of electrode is regarded as an effective stimulator during facial nerve
recordings: - ANSWER: Bipolar concentric EMG needle


Which time constant of a locut filter would be most effective for cutting out low
frequency noise from your signal? - ANSWER: 10 ms


The input impedance of a differential amplifier should be: - ANSWER: At least
100,000,000 ohms


What will be the frequency of a signal if in a 30 msec sweep the interval between
each cycle of the signal is 0.03 msec? - ANSWER: 33 KHz

, 4|Page


What is the initial event that occurs when the action potential threshold of a neuron
is reached? - ANSWER: Voltage-gated Sodium channels open


Lower motor neurons primarily exit the spinal cord through: - ANSWER: The
ventral nerve roots


A positive Babinski reflex could indicate: - ANSWER: Severe spinal cord trauma


After-discharges occur after what? - ANSWER: Direct cortical stimulation


Cotrel-Dubousset instrumentation involves which of the following as a primary
corrective maneuver? - ANSWER: Derotation


What is the maximum allowable leakage current from the isolated amplifier inputs
through the patient leads? - ANSWER: 10 uA


Random spike discharges can be heard from a speaker during facial nerve
dissection in all of the following except: - ANSWER: During electrocautery


The positive input of a differential amplifier is also called the - ANSWER: Non-
inverting input


Cranial nerve X can be monitored using electrodes inserted into the: - ANSWER:
Vocalis muscle


Microvascular decompression involves: - ANSWER: Lifting an artery off of the
nerve

Geschreven voor

Vak

Documentinformatie

Geüpload op
15 juni 2025
Aantal pagina's
52
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$12.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
AcademicSuperScores Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
299
Lid sinds
3 jaar
Aantal volgers
37
Documenten
7648
Laatst verkocht
2 weken geleden
AcademicSuperScores

NURSING, ECONOMICS, MATHEMATICS, BIOLOGY AND HISTORY MATERIALS. BEST TUTORING, HOMEWORK HELP, EXAMS, TESTS AND STUDY GUIDE MATERIALS WITH GUARANTEE OF A+ I am a dedicated medical practitioner with diverse knowledge in matters Nursing and Mathematics. I also have an additional knowledge in Mathematics based courses (finance and economics)

4.6

156 beoordelingen

5
125
4
9
3
11
2
5
1
6

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen