NEC Code Practice Test 2 () ACTUAL EXAM (TESTING REAL EXAM
NEC Code Practice Test 2
QUESTIONS) AND VERIFIED ANSWERS (MULTIPLE CHOICES)
Study online at https://quizlet.com/_4jc39d
|COMPLETE SOLUTIONS |A+ GRADED |100% CORRECT!!
1. Flexible cords is permitted to be run through holes in False
walls, structural ceilings, suspended or dropped ceil-
ings or floors:
True
False
2. The total rating of a cord and plug connected room air b. 50%
conditioner must not exceed ______ of the rating of a
branch circuit where lighting outlets, other appliances,
or general use receptacles are also supplied
a. 75%
b. 50%
c. 100%
d. 80%
3. Except for storable pools, fixed or stationary equip- d. 3 ft
ment other than an underwater luminaire cord must
not exceed ____ in length:
a. 4.5 ft
b. 2.5 ft
c. 5 ft
d. 3 ft
4. Receptacles located more than _____ above the floor b. 5.5 ft
are not required to be tamper resistant:
a. 4.5 ft
b. 5.5 ft
c. 4 ft
d. 6 ft
1/5
, NEC Code Practice Test 2
Study online at https://quizlet.com/_4jc39d
5. The feeder circuit for a mobile or a mobile or manu- a. 100 A
factured home must be rated at not less than ____ at
120/240V
a. 100 A
b. 50 A
c. 75 A
d. 200 A
6. Ceiling grid which supports the wires may be permit- False
ted to support raceways:
True
False
7. ______ circuit breakers or sets of fuses are acceptable a. 2 to 6
as over current device to provide overload protection
in one family dwellings:
a. 2 to 6
b. 2 to 12
c. 4 to 6
d. 4 to 12
8. At least _____ of free conductor, measured from the c. 6 in
point in the box where it emerges from its raceway or
cable sheath shall be left at each outlet, junction and
switch point:
a. 5 in
b. 4 in
2/5
NEC Code Practice Test 2
QUESTIONS) AND VERIFIED ANSWERS (MULTIPLE CHOICES)
Study online at https://quizlet.com/_4jc39d
|COMPLETE SOLUTIONS |A+ GRADED |100% CORRECT!!
1. Flexible cords is permitted to be run through holes in False
walls, structural ceilings, suspended or dropped ceil-
ings or floors:
True
False
2. The total rating of a cord and plug connected room air b. 50%
conditioner must not exceed ______ of the rating of a
branch circuit where lighting outlets, other appliances,
or general use receptacles are also supplied
a. 75%
b. 50%
c. 100%
d. 80%
3. Except for storable pools, fixed or stationary equip- d. 3 ft
ment other than an underwater luminaire cord must
not exceed ____ in length:
a. 4.5 ft
b. 2.5 ft
c. 5 ft
d. 3 ft
4. Receptacles located more than _____ above the floor b. 5.5 ft
are not required to be tamper resistant:
a. 4.5 ft
b. 5.5 ft
c. 4 ft
d. 6 ft
1/5
, NEC Code Practice Test 2
Study online at https://quizlet.com/_4jc39d
5. The feeder circuit for a mobile or a mobile or manu- a. 100 A
factured home must be rated at not less than ____ at
120/240V
a. 100 A
b. 50 A
c. 75 A
d. 200 A
6. Ceiling grid which supports the wires may be permit- False
ted to support raceways:
True
False
7. ______ circuit breakers or sets of fuses are acceptable a. 2 to 6
as over current device to provide overload protection
in one family dwellings:
a. 2 to 6
b. 2 to 12
c. 4 to 6
d. 4 to 12
8. At least _____ of free conductor, measured from the c. 6 in
point in the box where it emerges from its raceway or
cable sheath shall be left at each outlet, junction and
switch point:
a. 5 in
b. 4 in