Questions with expert solutions
( 100% accurate )
CSST fitting - answer All fittings and accessories in the
installation of CSST piping systems she'll be approved by the
CSST manufacturer for use with their systems and she'll only be
installed by a licensed CNA who have completed manufacture
training acceptable to the board
Exterior meter connections - answer No CSST shall be connected
to an exterior meter. The tubing shall terminate at the foundation
wall, with a termination fitting in the meter shall be rigidly
connected with steel piping to the building structure
Fireplace log installations - answer CSST shall terminate with a
termination fitting at the entrance of the Masonary firebox. The
workmanship shall be performed and completed in such a manner
so that the termination will not be exposed to any adverse effects.
Interior meter connections - answer Interior meter connections
may be directly connected to the CSST system as long as the
meter is securely affixed to the building in the CSST is secured to
the building structure within the 24 inches or more of tubing is
exposed.
Now are you both feeling shall be permitted in concealed location
when used in combination with what - answer CSST