Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

MRSO FINAL EXAM 2025| BRAND NEW ACTUAL EXAM WITH 100% VERIFIED QUESTIONS AND CORRECT SOLUTIONS| GUARANTEED VALUE PACK| ACE YOUR GRADES.

Rating
-
Sold
-
Pages
42
Grade
A+
Uploaded on
21-06-2025
Written in
2024/2025

MRSO FINAL EXAM 2025| BRAND NEW ACTUAL EXAM WITH 100% VERIFIED QUESTIONS AND CORRECT SOLUTIONS| GUARANTEED VALUE PACK| ACE YOUR GRADES. 1. Which of the following refer to the crescendo of magnetic fields that are demonstrated as we approach the MR unit? A. Time-varying gradient field B. RF field C. Static field D. Fringe field - correct answer - 2. Implants with leads or wires will have a better chance of heating up at 3.0T than at 1.5T. A. True B. False - correct answer - B. False 3. Which of the following will demonstrate the steepest magnetic spatial gradient? A. Short-bore B. Long-bore C. Depends on other factors. - correct answer - A. Short-bore 4. What is the difference between a shielded MR unit and an MR unit that is not shielded? A. It will make the magnetic spatial gradient more uniform. B. The magnetic spatial gradient is more confined to the MR unit.P a g e | 2 C. It will cause the effects of translational force to be experienced further away from the MR unit. D. It will push the 5 G line closer to the entrance of zone IV. - correct answer - B. The magnetic spatial gradient is more confined to the MR unit. 5. Which of the following will not exaggerate an artifact on an MR brain scan? A. A brain aneurysm clip B. ferrous foreign body in their skull C. non-ferrous earrings. - correct answer - C. non-ferrous earrings. 6. Which of the following can be used to reduce artifacts in the image? A. Decrease receiver bandwidth. B. Use a GRASS pulse sequence. C. Decreasing the image matrix. D. Running a PD sequence rather than a T2. - correct answer - D. Running a PD sequence rather than a T2. 7. Which of the following organizations help conduct research and produce regulations? A. IEC B. FDA C. ASTM D. All of the choices. - correct answer - D. All of the choices. 8. Which of the following are conditions that will make an object MR safe?P a g e | 3 A. Non-metallic B. Non-magnetic C. Non-conductive D. All of the choices - correct answer - D. All of the choices. 9. Which of the following modes will limit the SAR to the head to 3.2W/kg? A. Normal mode.. B. First Level Controlled Mode. C. Second Level Controlled Mode. D. Normal and First Level Controlled Mode. - correct answer - D. Normal and First Level Controlled Mode. 10. The Main focus of th

Show more Read less
Institution
Course

Content preview

Page |1


MRSO FINAL EXAM 2025| BRAND NEW ACTUAL
EXAM WITH 100% VERIFIED QUESTIONS AND
CORRECT SOLUTIONS| GUARANTEED VALUE
PACK| ACE YOUR GRADES.

1. Which of the following refer to the crescendo of magnetic fields that are
demonstrated as we approach the MR unit?
A. Time-varying gradient field
B. RF field
C. Static field
D. Fringe field - correct answer -




2. Implants with leads or wires will have a better chance of heating up at
3.0T than at 1.5T.
A. True
B. False - correct answer - B. False




3. Which of the following will demonstrate the steepest magnetic spatial
gradient?
A. Short-bore
B. Long-bore
C. Depends on other factors. - correct answer - A. Short-bore




4. What is the difference between a shielded MR unit and an MR unit that
is not shielded?
A. It will make the magnetic spatial gradient more uniform.
B. The magnetic spatial gradient is more confined to the MR unit.

, Page |2

C. It will cause the effects of translational force to be experienced further
away from the MR unit.
D. It will push the 5 G line closer to the entrance of zone IV. - correct
answer - B. The magnetic spatial gradient is more confined to the MR
unit.




5. Which of the following will not exaggerate an artifact on an MR brain
scan?
A. A brain aneurysm clip
B. ferrous foreign body in their skull
C. non-ferrous earrings. - correct answer - C. non-ferrous earrings.




6. Which of the following can be used to reduce artifacts in the image?
A. Decrease receiver bandwidth.
B. Use a GRASS pulse sequence.
C. Decreasing the image matrix.
D. Running a PD sequence rather than a T2. - correct answer - D.
Running a PD sequence rather than a T2.




7. Which of the following organizations help conduct research and produce
regulations?
A. IEC
B. FDA
C. ASTM
D. All of the choices. - correct answer - D. All of the choices.




8. Which of the following are conditions that will make an object MR safe?

, Page |3

A. Non-metallic
B. Non-magnetic
C. Non-conductive
D. All of the choices - correct answer - D. All of the choices.




9. Which of the following modes will limit the SAR to the head to 3.2W/kg?
A. Normal mode..
B. First Level Controlled Mode.
C. Second Level Controlled Mode.
D. Normal and First Level Controlled Mode. - correct answer - D. Normal
and First Level Controlled Mode.




10. The Main focus of the ICNIRP in MRI is what?
A. Radiation dose.
B. Occupational dose. - correct answer - B. Occupational dose.




11. The FDA performs research and testing.
A. True
B. False - correct answer - B. False




12. Which of the following would most likely be considered a Level 1 MR
Personnel?
A. MR Technologist
B. Radiologist
C. Someone who has not received MR Safety training in 1 year.
D. Tech aid - correct answer - D. Tech aid

, Page |4



13. We would find a patient changing into a gown in what zone?
A. Zone I
B. Zone II
C. Zone III
D. Zone IV - correct answer - B. Zone II




14. NEMA will perform testing on materials
A. True
B. False - correct answer - A. True




15. A herrington rod is an example of what?
A. Passive implant.
B. Active implant.
C. Both - correct answer - A. Passive implant.




16. The greatest chance of a burn to a patient comes from which of the
following?
A. Static magnetic field.
B. Time-varying gradient magnetic field.
C. Time-varying radiofrequency field. - correct answer - C. Time-varying
radiofrequency field.




17. Which of the following poses the greatest concern for a patient with
dermal anchors?
A. Static magnetic field
B. Time-varying gradient magnetic field.

Written for

Course

Document information

Uploaded on
June 21, 2025
Number of pages
42
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$12.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF


Also available in package deal

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
AcademicSuperScores Chamberlain College Of Nursing
Follow You need to be logged in order to follow users or courses
Sold
299
Member since
3 year
Number of followers
37
Documents
7648
Last sold
2 weeks ago
AcademicSuperScores

NURSING, ECONOMICS, MATHEMATICS, BIOLOGY AND HISTORY MATERIALS. BEST TUTORING, HOMEWORK HELP, EXAMS, TESTS AND STUDY GUIDE MATERIALS WITH GUARANTEE OF A+ I am a dedicated medical practitioner with diverse knowledge in matters Nursing and Mathematics. I also have an additional knowledge in Mathematics based courses (finance and economics)

4.6

156 reviews

5
125
4
9
3
11
2
5
1
6

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions