Correct
A patient/client is very interested in connectivity and does not want to wear a gateway
device while speaking hands-free on the phone and listening through their hearing
instruments. What wireless technology should be recommended?
A-Telecoil
B-700 MHz
C-NFMI
D-2.4 GHz - ANSWER D- 2.4 GHz
A first time hearing aid wearer and partner come in for the first follow-up. The partner
reports that the patient/client cannot hear the partner while in different rooms and that
the patient/client is still having difficulty hearing everything at their favorite restaurant.
What should be reviewed with the patient/client and their partner?
A-Realistic expectations
B-Being patient
C-Manufacturer's app
D-Cleaning and maintenance - ANSWER A- Realistic expectations
A teacher is having difficulty at work hearing and understanding the students especially
when the classroom is noisy, and has concerns that hearing loss is affecting their job
performance. Speech-in-noise testing demonstrates a significant breakdown for
sentence identification at SNRs of +10 dB and lower. What should be recommended?
A-Binaural amplification using RIC/RITE hearing instruments with noise suppression
and directionality
B-Improve the signal-to-noise ratio in the classroom using draperies and carpet
C-A trial period with an FM system for the classroom
D-Binaural amplification using IICs so that the students don't see them and become
uncomfortable - ANSWER A-Binaural amplification using RIC/RITE hearing
instruments with noise suppression and directionality
What criteria determines that the plateau has been reached during masked testing?
A-When effective masking causes a shift in the TE
threshold
B-When accurate and valid thresholds are
measured
,C-When effective masking is applied without a shift in the
TE threshold
D-When the patient/client reports that they hear the tone in the TE -
ANSWER C-When
effective masking is applied without a shift in the TE
threshold
During follow-up, a patient/client reports having difficulty hearing their spouse in the
presence of background noise. What should be recommended?
A-Use of an omni-directional program
B-Use of a remote microphone
C-Activation of frequency transposition
D-Decrease overall gain - ANSWER B- Use of a remote microphone
The patient/client with the above test results is being fit with an RIC hearing instrument.
Which dome should be selected?
A-Non-occluding open dome
B-Occluding double dome
C-Open tulip dome
D-Non-occluding closed dome - ANSWER B-Occluding double dome
What is considered the single most significant factor in hearing instrument acceptance
and use?
A-Free batteries during the warranty period
B-A flexible trial period
C-Premium level hearing instruments
D-Post-fitting care - ANSWER D- Post-fitting Care
What activity should be completed with a patient/client who wants to purchase hearing
instruments because they are having difficulty hearing in a number of different listening
environments?
A-Comparison of unaided and aided WR ability in the soundfield
B-The COSI
C-The SII
D-The HHI - ANSWER B- The COSI
Based on the above audiogram, WR testing in the left ear will be performed at MCL for
speech (85 dB HL) using insert earphones. What intensity of masking noise should be
applied for WR testing in the left ear?
, A-85 dB HL in the right ear
B-65 dB HL in the right ear
C-85 dB HL in the left ear
D-65 dB HL in the left ear - ANSWER B-65 dB HL in the right ear
What is the first thing to do after completing post-fitting validation measures?
A-Make acoustic changes to the hearing instrument's programming
B-Tell the patient/client that the same measures will be completed after the patient/client
has used their hearing instruments for another couple of weeks
C-Complete verification measures again
D-Discuss the differences between the patient's/client's pre-fitting and post-fitting
validation measures with the patient/client - ANSWER D-Discuss the differences
between the patient's/client's pre-fitting and post-fitting validation measures with the
patient/client
What needs to be compared to determine the type hearing loss?
A-AC and BC SRTs
B-Thresholds and UCLs
C-AC and BC thresholds
D-AC thresholds and normal hearing - ANSWER C- AC and BC thresholds
What is the benefit of measuring thresholds for all octave and inter-octave frequencies?
A-The hearing instrument fitting potential is optimized
B-The audiogram appears more professional
C-Better test-retest reliability
D-Better predictive value for speech audiometry - ANSWER A-The hearing instrument
fitting potential is optimized
A patient/client presents with a progressive bilateral sensory/neural hearing loss that is
now profound with significantly reduced WR ability in both ears. The patient/client
reports that hearing instruments are no longer providing benefit. What should be
recommended?
A-Monaural hearing instrument fitting on the best ear
B-BAHA consultation
C-Binaural premium power hearing instruments
D-Cochlear implant consultation - ANSWER D-Cochlear implant consultation
A patient/client and their family are motivated to learn about general communication