Generally , sleeves should be at least _____larger than the irrigation piping required. -
ANSWER 2 sizes
PVC pipe with the same physical dimension as iron pipe? - ANSWER Schedule pipe
The process of plant material giving off vapor from the leaves ? - ANSWER
Transpiration
shock wave created by a fast closing valve ? - ANSWER Water hammer
act of chemically fusing PVC pipe and fittings together? - ANSWER solvent welding
PVC is an abbreviation for ? - ANSWER Polyvinyl Chloride
Flexible part of an automatic valve which regulates the passage of water? - ANSWER
Diaphragm
What does I.P.S. stand for ? - ANSWER Iron plastic size
What does M.I.P. stand for ? - ANSWER male iron pipe
An irrigation system with any kind of injection device associated with it would be termed
as ____? - ANSWER Health Hazard
Which back flow device is required to be used with pumps ? - ANSWER Which ever
one is required by state or local codes .
The mechanical prevention of reverse flow, or back siphonage , of non-potable water
from an irrigation system into the public water system is called ? - ANSWER Back flow
prevention
Any pressure,regardless of its source ,against the outlet side of the back flow prevention
device ,which exceeds the supply pressure against the inlet side of the device is? -
ANSWER Back pressure
Which back flow device is most recommended for systems with fertilizer injectors? -
ANSWER Reduced pressure principle
, Which back flow device is recommended for low hazard applications? - ANSWER
atmospheric vacuum breaker
pressure vacuum breaker
double check assembly
reduced pressure principle all
of them.
Which back flow device can be installed below grade ? - ANSWER Double check
assembly
Which back flow device can be under constant pressure? - ANSWER Pressure vacuum
breaker
Double check assembly
Reduced pressure principle
Which back flow device is acceptable to use when there is a possibility of back
pressure? - ANSWER Double check assembly
Reduced pressure principle
Which back flow device is recommended to prevent back siphonage ? - ANSWER AVB
PVB
DCA
RPZ
An atmospheric vacuum breaker is not suitable for__? - ANSWER Back pressure
statement correct>>> - ANSWER A pressure vacuum breaker, unlike the admospheric
vacuum breaker, will operate satisfactorily under constant pressure.
Back flow in the water distribution system can be caused by: - ANSWER Back pressure
and Back siphonage
A pressure vacuum breaker may be installed with a : - ANSWER Control valve
immediately downstream
Back prevention assemblies on high hazard systems should be repaired : - ANSWER
When field test results show failure
A control valve downstream a back flow device may result in : - ANSWER Constant
pressure
Where are the shut- offs valves located on an ABV ? - ANSWER There are no shut - off