CDC Mobile Water Supply Complete Questions And
Answers Rated A+
,CDC Mobile Water Supply Complete Questions And
Answers Rated A+
You are stationed in Alaska in December. You've just come back from a
company inspection to find that your stall door will not operate and cannot
be fixed until the following day. To prevent damage from freezing you should:
Drain the piping, pump, and booster lines to prevent damage.
When testing the priming device on an MWS apparatus with a fire pump with
a capacity less than 1,500 gpm, the priming device should be able to create
the necessary vacuum in 30 seconds to lift water 10 feet through:
20 feet of hard suction hose.
identify FOUR pre-service for an MWS apparatus equipped with a fire pump.
•Road test
• Independent pump certification tests
• Purchase acceptance tests
• Hydrostatic tests
Identify THREE items that are checked for leaks during the vacuum test.
, CDC Mobile Water Supply Complete Questions And
Answers Rated A+
•Priming device
• Hard suction hose
• Pump
Identify THREE pieces of equipment needed to conduct service testing on an
MWS apparatus equipped with a fire pump.
•Tachometer
•Smoothbore tips
•External test gauges
When performing a vacuum service test, once the engine is turned off, the
column of mercury should fall no more than:
10 inches in 5 minutes
Tracking engine performance across time uses data collected in the:
Fuel, oil, and mileage record.
Identify THREE critical items that should be included on an MWS apparatus
daily inspection checklist.
Answers Rated A+
,CDC Mobile Water Supply Complete Questions And
Answers Rated A+
You are stationed in Alaska in December. You've just come back from a
company inspection to find that your stall door will not operate and cannot
be fixed until the following day. To prevent damage from freezing you should:
Drain the piping, pump, and booster lines to prevent damage.
When testing the priming device on an MWS apparatus with a fire pump with
a capacity less than 1,500 gpm, the priming device should be able to create
the necessary vacuum in 30 seconds to lift water 10 feet through:
20 feet of hard suction hose.
identify FOUR pre-service for an MWS apparatus equipped with a fire pump.
•Road test
• Independent pump certification tests
• Purchase acceptance tests
• Hydrostatic tests
Identify THREE items that are checked for leaks during the vacuum test.
, CDC Mobile Water Supply Complete Questions And
Answers Rated A+
•Priming device
• Hard suction hose
• Pump
Identify THREE pieces of equipment needed to conduct service testing on an
MWS apparatus equipped with a fire pump.
•Tachometer
•Smoothbore tips
•External test gauges
When performing a vacuum service test, once the engine is turned off, the
column of mercury should fall no more than:
10 inches in 5 minutes
Tracking engine performance across time uses data collected in the:
Fuel, oil, and mileage record.
Identify THREE critical items that should be included on an MWS apparatus
daily inspection checklist.