Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

U1 UST INSTALLATION/RETROFITTING NEWEST 2025 COMPLETE 150 QUESTIONS AND CORRECT ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+

Beoordeling
-
Verkocht
-
Pagina's
29
Cijfer
A+
Geüpload op
27-06-2025
Geschreven in
2024/2025

U1 UST INSTALLATION/RETROFITTING NEWEST 2025 COMPLETE 150 QUESTIONS AND CORRECT ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+ observation wells locates I the tank excavation and monitoring wells installed in native soil outside the tank excavation. may be used for leak detection only if? - ANSWER-the water table is within 20' of the ground surface all times of the year. construct wells of factory slotted PVC or coated metallic pipe with 0.020-inch openings and allow water or released product to flow freely into the well. - ANSWER-observation well must be 1 t0 2' below the bottom of the tank. monitoring well must be 5' below water table to a maximum of 5'. schedule 40 factory wrapped coated steel pipe is the minimum standard for metallic product piping. - ANSWER-if u ions are installed under ground they should be 250/300 ground joint onions and provide access to service. install fill pipe so the top of fill ca pl will be? - ANSWER-4 to 6" below the manhole lid. air test new single wall or double wall piping at? - ANSWER-50 psig It test primary coaxle piping at? - ANSWER-50 psig for 1 hour. for fiberglass secondary piping initial testing, test at? - ANSWER-10 psig, if flexible connectors are used test at 5 psig. 2 | Page U1 UST Installation/Retrofitting dialetric coatings isolate the external surfaces of thank and piping from the environment and reduce current demand on the catholic protection. coatings may be? - ANSWER-coal tar foxes, enamels, fiberglass reinforced plastic or urethane in liquid form, tape or extrusions. connect the rectifier negative terminal to the structure and positive terminal to the anodes. - ANSWER-Install on a dedicated electrical circuit. ball float vent valves will not work when? - ANSWER-when coaxle stage 1 vapor recovery systems are installed. vacuume assist stage 2 vapor recovery is recommended for above ground storage systems unless? - ANSWER-the distance between vehicle tank and storage tank is a short distance. stage 2 vapor recovery may include a liquid removal? - ANSWER-if the hose extends more then 10" downward from the fuel inlet to the nozzle when hung on the dispenser. vapor valves must be located in? - ANSWER-a nozzle, in the dispenser cabinet or on the vapor/ liquid splitter fitting. a ball valve may be installed in the vapor piping above? - ANSWER-the vapor shear valve so the vapor handling components and hanging hardware can be isolated from the underground vapor piping shear valves must be anchored to both? - ANSWER-didpensor island and the framework vapor risers beneath dispensers are constructed of? - ANSWER-1" diameter pipe

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

U1 UST Installation/Retrofitting


U1 UST INSTALLATION/RETROFITTING NEWEST 2025 COMPLETE
150 QUESTIONS AND CORRECT ANSWERS (VERIFIED ANSWERS)
|ALREADY GRADED A+
observation wells locates I the tank excavation and monitoring wells installed in native soil
outside the tank excavation. may be used for leak detection only if? - ANSWER-the water table
is within 20' of the ground surface all times of the year.



construct wells of factory slotted PVC or coated metallic pipe with 0.020-inch openings and
allow water or released product to flow freely into the well. - ANSWER-observation well must be
1 t0 2' below the bottom of the tank. monitoring well must be 5' below water table to a
maximum of 5'.




schedule 40 factory wrapped coated steel pipe is the minimum standard for metallic product
piping. - ANSWER-if u ions are installed under ground they should be 250/300 ground joint
onions and provide access to service.



install fill pipe so the top of fill ca pl will be? - ANSWER-4 to 6" below the manhole lid.



air test new single wall or double wall piping at? - ANSWER-50 psig



It test primary coaxle piping at? - ANSWER-50 psig for 1 hour.



for fiberglass secondary piping initial testing, test at? - ANSWER-10 psig, if flexible connectors
are used test at 5 psig.




1|Page

, U1 UST Installation/Retrofitting

dialetric coatings isolate the external surfaces of thank and piping from the environment and
reduce current demand on the catholic protection. coatings may be? - ANSWER-coal tar foxes,
enamels, fiberglass reinforced plastic or urethane in liquid form, tape or extrusions.




connect the rectifier negative terminal to the structure and positive terminal to the anodes. -
ANSWER-Install on a dedicated electrical circuit.




ball float vent valves will not work when? - ANSWER-when coaxle stage 1 vapor recovery
systems are installed.



vacuume assist stage 2 vapor recovery is recommended for above ground storage systems
unless? - ANSWER-the distance between vehicle tank and storage tank is a short distance.



stage 2 vapor recovery may include a liquid removal? - ANSWER-if the hose extends more then
10" downward from the fuel inlet to the nozzle when hung on the dispenser.



vapor valves must be located in? - ANSWER-a nozzle, in the dispenser cabinet or on the vapor/
liquid splitter fitting.



a ball valve may be installed in the vapor piping above? - ANSWER-the vapor shear valve so the
vapor handling components and hanging hardware can be isolated from the underground vapor
piping



shear valves must be anchored to both? - ANSWER-didpensor island and the framework



vapor risers beneath dispensers are constructed of? - ANSWER-1" diameter pipe



2|Page

, U1 UST Installation/Retrofitting

size of vapor recovery piping is typically - ANSWER-2 to 3" in diameter between dispensers.



when performing a pre installation pressure test of a double wall tank pressure up the? -
ANSWER-inner tank to 5 psig for 1 hour soaping all components then pressure the interstice
with air from the inner tank and soap all components. first release pressure from interstice then
the inner tank.



when a bottom hold down pad is used under a steel tank. - ANSWER-the bedding material may
be reduced to 6"



cover in areas that are subject to vehicle traffic - ANSWER-30" compacted backfill and 6" of
asphaltic concrete, or 18" of compacted backfill and 6 to 8" of reinforced concrete. paving over
tanks in traffic areas should extend 1 foot beyond tank perimeter.



cover in non traffic areas should be atleast 2' thick and consist of a minimum of 1' of backfill
covered by filter fabric and a minimum of 1' earth. - ANSWER-an acceptable alternative is 1'
backfill material and atleast 4" of reinforced concrete or 6" of asphalt paving.



the maximum burial depth for fiberglass tanks - ANSWER-7'



the burial depth for steel tanks is? - ANSWER-5'



to provide a firm foundation set tanks on atleast....... of backfill - ANSWER-1' thick that extends
1' beyond ends and sides of tank.



how many feet of backfill is required between adjacent tanks and tanks and excavation wals? -
ANSWER-2'



excavation material must be stockpiled atleased..... from tank - ANSWER-2'

3|Page

Geschreven voor

Vak

Documentinformatie

Geüpload op
27 juni 2025
Aantal pagina's
29
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$13.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
SophiaBennettRN Teachme2-tutor
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
24
Lid sinds
1 jaar
Aantal volgers
1
Documenten
2262
Laatst verkocht
1 week geleden
TopGrade Tutor: Expert Psychology, Nursing, Pharmacology & Computer and Math Resources

Welcome to my academic support store, your trusted destination for top-tier homework help and tutoring services! Specializing in key subjects like Psychology, Nursing, Human Resource Management, and Mathematics, I’m dedicated to helping students excel with high-quality, meticulously crafted resources. My mission is to deliver scholarly, reliable content that guarantees excellent grades, earning me a reputation as one of Stuvia’s BEST GOLD RATED TUTORS. Whether you need assistance with quizzes, exams, or detailed study materials, I prioritize your success with a commitment to academic excellence and results you can count on

Lees meer Lees minder
3.9

7 beoordelingen

5
4
4
1
3
0
2
1
1
1

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen