____________ detectors contain multiple sensors and are capable of generating multiple alarms. - multi-sensor ____________ detectors employ more than one operating principle and operate independent of each other. - combination ____________ detectors are used to protect large areas. it is a light beam broken by combustible particles. - beam ___________ detectors shut down a buildings hvac system and redirect airflow. - dust smoke fire alarm devices shall be protected, especially during ___________. - installation for air sampling type detectors, the maximum air sampling transport time from the farthes point shall not exceed ____________. - 120 seconds air-sampling detectors shall give a ____________ signal if the airflow is outside the manufacurers specified range. - trouble maximum allowable time for fire alarm output functions to operate once a smoke detector has been activated is __________ seconds. - 10 __________ heat detectors do not have to be replaced after it has activated the fire alarm. - rate of rise

Show more Read less
Institution
S-95 SUPERVISION OF FIRE ALARM
Course
S-95 SUPERVISION OF FIRE ALARM

Content preview

S-95 SUPERVISION OF FIRE ALARM
SYSTEMS

____________ detectors contain multiple sensors and are capable of
generating multiple alarms. - ✔ ✔ multi-sensor

____________ detectors employ more than one operating principle
and operate independent of each other. - ✔ ✔ combination

____________ detectors are used to protect large areas. it is a light
beam broken by combustible particles. - ✔ ✔ beam

___________ detectors shut down a buildings hvac system and re-
direct airflow. - ✔ ✔ dust smoke

fire alarm devices shall be protected, especially during ___________. -
✔ ✔ installation

for air sampling type detectors, the maximum air sampling transport
time from the farthes point shall not exceed ____________. - ✔ ✔
120 seconds

air-sampling detectors shall give a ____________ signal if the airflow is
outside the manufacurers specified range. - ✔ ✔ trouble

maximum allowable time for fire alarm output functions to operate
once a smoke detector has been activated is __________ seconds. - ✔
✔ 10

__________ heat detectors do not have to be replaced after it has
activated the fire alarm. - ✔ ✔ rate of rise

, ________ heat detectors activate the alarm when the detector
components melt at a preset temperature. - ✔ ✔ fixed-temperature
heat detectors

__________ heat detectors are the most commonly used. - ✔ ✔
fixed-temperature

___________ detectors are required in any building that has fossil fuel
burning equipment. - ✔ ✔ carbon monoxide

the _________ shall only be reset at the direction of a fire department
representative. - ✔ ✔ fire alarm control panel

single action stations are usually found __________. - ✔ ✔ indoors

once activated, the fire alarm system cannot be re-set at the
_____________. - ✔ ✔ fire alarm manual pull station

a master plumber with an s-12 cof is allowed to perform maintenance
on sprinkler systems in residential occupancies with less than
____________ sprinklers. - ✔ ✔ 30

when a ____________ condition is indicated, the cof holder should
check the system in order to identify the part of the system that caused
the signal. - ✔ ✔ supervisory

all subsystems are subject to fdny inspection and test for issuance of
_______________. - ✔ ✔ letter of approval

in large buildings, the fire annunciator may be associated with
____________ control and _____________ systems. - ✔ ✔ smoke
purge, communications

Written for

Institution
S-95 SUPERVISION OF FIRE ALARM
Course
S-95 SUPERVISION OF FIRE ALARM

Document information

Uploaded on
July 2, 2025
Number of pages
6
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$8.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
jackline98 Stanford University
Follow You need to be logged in order to follow users or courses
Sold
269
Member since
2 year
Number of followers
152
Documents
9860
Last sold
2 weeks ago

Here you will find different past papers with correct and updated solutions .Please do not forget to leave a review after purchasing any document .Goodluck and success in advance.

3.3

61 reviews

5
21
4
11
3
9
2
5
1
15

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions