Steel Deck pg 6:
D. All the above correct answers After installation and adequate fastening, floor decks serve
several purposes:
A. Acts as a working platform
B. Stabilizes the frame
C. Serves as concrete form for the slab
D. All the above
Steel Deck pg 6:
Panel ends do not overlap correct answers Composite floor deck is normally installed so the
__________________
Steel Deck pg 7:
Acts alone in transferring horizontal and vertical loads into the building frame. correct answers
Roof deck is not designed to act compositely with other materials. The roof
deck________________________
Steel Deck pg 7:
2" correct answers Roof deck is typically installed to end lap approximately _________ inches
over supports.
Steel Deck pg 8:
Cellular Deck correct answers ___________________ can be used in the same manner as floor
deck. Electrical, telephone and computer wires are easily run through the chase created between
the deck panel and the bottom sheet.
Steel Deck pg 9:
,2 to 4 psf correct answers A 3' x 12" composite floor deck will have a nominal thickness range
of. 03 inches to. 06 inches and a weight range of ____ to _____ psf
Steel Deck pg 10:
1 1/2" X 6" Intermediate Rib correct answers F deck may also be referred to as______________
for the name,. 03 inches two. 06 inches for the thickness and 2 to 4 PSF for the weight.
Steel Deck pg 12:
4 to 7 PSF correct answers The weight range for cellular floor decking is__________
Steel Deck pg 11:
15/16" and 0.017" to 0.040" correct answers A heavy duty form decks name used in centering
is______ Form deck with a thickness of_____ to _____ And a weight range of one to two PSF
Steel Deck pg 14:
4000 lbs correct answers Steel deck is banded into bundles that can weigh several thousand
pounds but the deck bundle weight will be limited to a maximum of_______________ For deck
to be applied to joists.
Steel Deck pg 18:
Stored off the ground, with one end elevated to provide drainage. correct answers If ground
storage is needed, the deck bundles should be______________
Steel Deck pg 18:
ALWAYS correct answers Deck bundles must________ be placed on the frame near a main
supporting beam at a column or a wall
Steel Deck pg 22:
Ends of the bundles rest on a bearing surface correct answers Bundles should be landed so that
the ___________________________ rather than having one or both ends cantilevered.
,Steel Deck pg 24:
12 correct answers Are you working area should be at least _________ feet wide.
Steel Deck pg 25:
Kneel correct answers When aligning the edge (side) lap, the worker should__________
Steel Deck pg 28:
Welds, self drilling screws, air driven, and power driven correct answers Deck fastening to the
structural frame can be accomplished with:
Steel Deck pg 30:
#12s or 1/4" in diameter correct answers Screws are typically_____ or ________ With a special
drill point when used to attach decking.
Steel Deck pg 32:
0.028" correct answers Weld washers are not recommended for deck thickness of_____
(Minimum of 22 gauge) and greater
Steel Deck pg 34:
75% (7/8ths previously) correct answers A good weld will have______ Or more of its perimeter
working.
Steel deck pg 34:
22 correct answers Welding side laps is not recommended for decks type____ Or lighter (0.028"
min.)
Steel deck pg 34:
Never correct answers Weld washers should___________ Be used at side laps between supports
, Steel Deck pg 37:
2 correct answers No reinforcing is generally required for an opening of 6 inches as long as not
more than____ webs are removed
Steel Deck pg 38:
0.057" minimum plate correct answers For holes or dents greater than a rib (8 inches to 13
inches), It is advisable to use a____________ to cover it
Steel Deck pg 43:
50 correct answers The deck should have been selected to provide at least___________ pounds
per square foot capacity as a working platform.
Steel Deck pg 43:
Placed and fully connected correct answers If the deck is to act as a diaphragm during
construction, it must be realize that the diaphragm is not effective until all deck units
are_______________
IBC pg 444
2113.9 Termination
IRC pg 452 R1003.9
A. 2' correct answers A chimney shall extend at least how many feet higher than any portion of a
building within 10 feet?
A. 2'
B. 3'
C. 5'
D. 6'
OSHA pg 329 sec 1926.451(b)(2)(ii)