Questions And Correct Answers (Verified Answers)
|Already Graded A+
Which two Factors that affect Fire Alarm Systems performance, are
mostly determined on the jobsite?
A-Equipment and System Design
B-Inspections and Maintenance
C-Installation and Maintenance
D-Installation and Equipment
- ans -C-Installation and Maintenance
What type of indication would appear at the Fire Alarm Control Panel
when a short circuit is introduced on a IDC?
A-No Indication
B-A Trouble Signal
C-A Supervisory Signal
D-An Alarm Signal
- ans -D-An Alarm Signal
A __________ is a device that is intended to detect flames and is
designed to operate in environments where sunlight or other ambient
lighting is assumed.
A- Flame detector
B- Smoke detector
C- Heat detector
D- Fire gas detector
- ans -A- Flame detector
All points on the ceiling shall have a detector within a distance equal to
_________ times the listed spacing.
A- 0.7
,B- 0.8
C- 0.9
D- 1.0 - ans -A- 0.7
Audible signal materials need to be protected against the effects of
________________ and shall be designed and fabricated to render
them damage and tamper resistant.
A- Climate
B- Fire
C- Moisture
D- All the Above - ans -D- All the Above
All materials for ________________ shall be moisture, fire, and climate
resistant in accordance with the state purpose and shall be designed
and fabricated to render them damage and tamper resistant.
I. Visible Appliances II. Textual III. Audible
A- I & II
B- II & III
C- I & III
D- I, II, &III - ans -D- I, II, &III
Records for all inspections, tests, and maintenance shall be kept on the
premise for at least ___________ for review by the authority having
jurisdiction.
A- 6 months
B- 1 year
C- 3 years
D- Life Time of System - ans -B- 1 year
The _________ shall provide for proper maintenance of the system.
A- Installer
B- Owner
C- Maintenance employee
, D- Occupant of premise - ans -B- Owner
A signal indicating an emergency requiring immediate action is define
as _______?
A- Alarm service
B- Supervisory Signal
C- Alarm Signal
D- Trouble Signal - ans -C- Alarm Signal
A document issued by the state fire marshal to a person who has
passed the prescribed tests which grants conditional permission to
perform the acts described on the document may be defined as
A- A contractor's Licence
B- A certificate of registration
C- An installation permit
D- A building permit - ans -B- A certificate of registration
Electrically operated circuits, instruments, and devices, together with
the necessary electrical energy, design to transmit fire alarm,
supervisory and trouble signals necessary for the protection of life and
property is defined as ______________?
A- Fire Alarm system
B- Annunciator system
C- Protective signaling system
D- Pre-engineered systems - ans -C- Protective signaling system
A fire alarm system designed to provide a general fire alarm and voice
communication the system may be used in whole or in part in common
with another signaling system such as Voice Page or musical program
system if all components are of a type approved by the state fire
marshal and the non-emergency system does not degrade the alarm
and paging functions of the system is defined as_____________?
A- Combination paging alarm system