Which agency approves a site-specific variance which allows for an alternative method
of construction or monitoring:
a.) The Regional Water Quality Board
b.) The State Water Resources Control Board
c.) The Department of Toxic Substance Control
d.) The local agency - answer:-a.) The Regional Water Quality Board
CCR Title 23, Sec 2681(a)

The regulations to enforce compliance of underground storage tank systems in the state
are found in?
a.) Code of Federal Regulations, 40 CFR Part 281
b.) California Code of Regulations, Title 23, Chapter 16
c.) Code of Federal Regulations, 40 CFR Part 280
d.) California Code of Regulations, Title 23, Chapter 17 - answer:-b.) California Code of
Regulations; Title 23, Chapter 16

By definition an "underground storage tank system" includes
a.) The tank, all connected piping and dispensers
b.) The tank, all connected piping, ancillary equipment and containment system
c.) Only the tank
d.) Only tanks totally beneath the surface of the ground - answer:-b.) The tank, all
connected piping, ancillary equipment and containment system

(H&SC, Sec 25281(z))

The written report submitted to the local agency after an unauthorized release is
required to include the following except:
a.) Description of actions taken to stop the release
b.) Cause of the release
c.) Method of disposal of released product
d.) Date on which the release was discovered - answer:-b.) Cause of the release
CCR Title 23, Sec 2652(c)

An unauthorized release which does not escape from secondary containment only
requires a record on the operator's monitoring reports provided:
A. It did not increase the hazard of fire
B. It did not cause any deterioration of the secondary containment
C. It was cleaned up within 8 hours of detection
D. All of the above - answer:-D. All of the above
H&SC, Sec 25294

The annual monitoring certification may be performed by:

,ICC California UST Inspector Exam:
Question And Answer.

A. A person possessing the appropriate contractors licenses
B. An individual trained and certified by the manufacturer of the monitoring equipment
C. A designated UST operator
D. A person who meets the requirements of both a and b - answer:-D. A person who
meets the requirements of both a and b
CCR Title 23, Sec 2715(i)

When an automatic tank gauge is utilized for single-walled tank leak detection, it shall
generate a post-test hard copy data report of the following information, except:
a.) Liquid volume
b.) Fuel depth
c.) Outside air temperature
d.) Time and date of test - answer:-c.) Outside air temperature
CCR Title 23, Sec 2643(b)(1)

If a UST system is utilizing an overfill alarm, the alarm must be triggered to alert the
transfer operator when the tank is no more than ___________ full
a.) 85%
b.) 95%
c.) 90%
d.) 80% - answer:-c.) 90%

An automatic tank gauge is utilized for leak detection of the ______________.
a.) Tank
b.) Tank and Piping
c.) Piping
d.) Interstitial space - answer:-a.) Tank
CCR Title 23, Sec 2643(b)(1)

After completion of enhanced leak detection (ELD) test, the ELD test results must be
submitted to the _________________.
a.) The local agency
b.) The SWRCB
c.) Owner of the UST system
d.) To both the SWRCB and the local agency - answer:-d.) To both the SWRCB and the
local agency
CCR Title 23, Sec 2644.1(a)(5)

A permit to operate a UST system must have all of the following listed on the permit,
EXCEPT:
a.) The state UST identification number(s)
b.) Name of the tank manufacturer and tank capacity

,ICC California UST Inspector Exam:
Question And Answer.

c.) Permit expiration date
d.) Monitoring requirements - answer:-b.) Name of the tank manufacturer and tank
capacity
CCR Title 23, Sec 2712(c)

A temporary closure is appropriate for which of the following:
a.) The UST system is empty and will be removed from service indefinitely
b.) The UST system has ceased to store hazardous materials but will be used within the
next 12 consecutive months
c.) The UST system is unable to meet compliance requirements and will be removed
d.) The UST system has been red-tagged - answer:-b.) The UST system has ceased to
store hazardous materials but will be used within the next 12 consecutive months
CCR Title 23, Sec 2671 & 2670

A local agency determines that a UST facility within the last year had compliance
issues. Prior to issuing a new permit or renewal to operate an UST the local agency
shall:
a.) Ask the state to assist in a joint inspection
b.) Request the owner/operator to submit a "Return to Compliance" form.
c.) Refer to a District Attorney Investigator
d.) Inspect the facility and determine compliance - answer:-d.) Inspect the facility and
determine compliance
CCR Title 23, Sec 2712(c)

All the following components require third party certification, except:
a.) Automatic tank gauging systems
b.) Statistical inventory reconciliation methods
c.) Spill Containment lids
d.) Liquid phase out-of-tank products - answer:-c.) Spill Containment lids

The exterior surface of an underground storage tank must bear a marking or label which
shows the following information, except:
a.) Design pressure in psig
b.) Useable capacity in gallons.
c.) Width of the interstitial space
d.) Identity of manufacturer - answer:-c.) Width of the interstitial space
CCR Title 23, Sec 2631(b)

Which of the following is not a confined space:
a.) A really deep turbine sump
b.) A space not designed for continuous employee occupancy
c.) An area with limited access

, ICC California UST Inspector Exam:
Question And Answer.

d.) An area with limited ventilation - answer:-d.) An area with limited ventilation
CCR Title 8, Sec 5157(b)

A secondary containment system which is not an integral part of primary containment
shall be designed and constructed according to an engineering specification approved
by a third party. The secondary containment system shall contain ______________ of
the volume of the largest primary container within it, in the case of multiple primary
containers:
a.) 100 percent
b.) 10 percent
c.) 110 percent
d.) 150 percent - answer:-d.) 150 percent
CCR Title 23, Sec 2631(e)(1)(B)

All the following are approved overfill prevention systems, except:
a.) Automatic shutoff devices
b.) Spill Containers
c.) Overfill alarms
d.) Flapper valves - answer:-b.) Spill Containers
CCR Title 23, Sec 2635(b)(2)

Automatic line leak detectors shall be installed on underground pressurized piping with
secondary containment and shall be capable of detecting a:
a.) 3-gallon per hour leak rate at 5 psi within 1 hour.
b.) .1-gallon per hour leak rate at 5 psi within 1 hour.
c.) 3-gallon per hour leak rate at 10 psi within 1 hour.
d.) .1-gallon per hour leak rate at 10 psi within 1 hour. - answer:-c.) 3-gallon per hour
leak rate at 10 psi within 1 hour.
CCR Title 23, Sec 2636(f)(2)(f)(3) & 2643(c)(1)

Individuals installing an Underground Storage Tank System shall meet all of the
following, except:
a.) California Licensed Tank Tester
b.) Possess the appropriate Contractors State License Board license.
c.) Effective January 1, 2005, the individual shall possess a current underground
storage tank system installer certificate from the ICC UST Installation/Retrofitting exam.
d.) The individual has been adequately trained as evidenced by a certificate of training
issued by the manufacturer(s) of the underground storage tank system component(s)
being installed. - answer:-a.) California Licensed Tank Tester
CCR Title 23, Sec 2715(g)(h)

Which of the following would not require secondary containment testing?

Geschreven voor

Vak

Documentinformatie

Geüpload op
15 juli 2025
Aantal pagina's
101
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$9.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
bryanwalker859

Maak kennis met de verkoper

Seller avatar
bryanwalker859 All Types of Notes
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
1
Lid sinds
10 maanden
Aantal volgers
0
Documenten
145
Laatst verkocht
6 maanden geleden

0.0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen