INSTALLER II
PRACTICE
Underground Easements from drip irrigation - ANSWERS-1 foot
Overhead easements from tanks - ANSWERS-1 foot unless permission
has been granted then none
Overhead easements from soil absorption systems & unlined beds -
ANSWERS-1 foot unless permission has been granted then none
Overhead easements from lined ET beds - ANSWERS-1 foot unless
permission has been granted
Overhead easements from sewer pipes with watertight joints -
ANSWERS-1 foot unless permission has been granted
Overhead easements from surface application - ANSWERS-1 foot
unless permission has been granted
END OF
PAGE
1
, TEXAS TCEQ LATEST
INSTALLER II
PRACTICE
Overhead easements from drip irrigation - ANSWERS-1 foot unless
permission has been granted
Slopes where seeps may occur and detention ponds from tanks -
ANSWERS-5 feet
Slopes where seeps may occur and detention ponds from soil absorption
systems & unlined ET beds - ANSWERS-25 feet
Slopes where seeps may occur and detention ponds from lined ET beds -
ANSWERS-5 feet
Slopes where seeps may occur and detention ponds from sewer pipe
with watertight joints - ANSWERS-10 feet
Slopes where seeps may occur and detention ponds from surface
application(Edge of spray area) - ANSWERS-10 feet
END OF
PAGE
2
, TEXAS TCEQ LATEST
INSTALLER II
PRACTICE
Slopes where seeps may occur and detention ponds from drip irrigation
with Ra<0.1 - ANSWERS-10 feet
Slopes where seeps may occur and detention ponds from drip irrigation
with Ra>0.1 - ANSWERS-25 feet
Edwards Aquifer from tanks - ANSWERS-50 feet
Edwards Aquifer from soil absorption systems & unlined ET beds -
ANSWERS-150 feet
Edwards Aquifer from lined evapotranspiration beds - ANSWERS-50
feet
Edwards Aquifer from sewer pipes with water tight joints - ANSWERS-
50 feet
Edwards Aquifer from surface application(Edge of spray area) -
ANSWERS-150 feet
END OF
PAGE
3