Design, material, and operational standards for DCVA & RPBA are found in the -
Correct Answers -AWWA standards

Approved backflow prevention assemblies must be designed to be - Correct Answers -
disassembled and repaired in line for all sizes

Check valves must be internally loaded and must be drip-tight - Correct Answers -in the
direction of flow with a minimum of 1 psi differential

The maximum allowable pressure loss through a 3/4" DCVA is - Correct Answers -10
psi

The maximum allowable pressure loss through a 3/4" RPBA is - Correct Answers -20
psi

The markings required to be on all approved backflow prevention assemblies include -
Correct Answers -make, model, direction of flow, & MWP

As part of an inspection of the assembly a BAT must determine - Correct Answers -if
the assembly is currently listed and approved for the orientation that it is installed

A cross-connection is defined as any actual or potential physical connection between a
public potable water system or the consumer's potable water system and any source of
non-potable liquid, solid, or gas that could the potable water supply by backflow -
Correct Answers -contaminate

The undesirable reversal of flow of water or other substances through a cross-
connection into the public water system or consumer's potable water system is - Correct
Answers -backflow

Backsiphonage backflow is defined as backflow due to a reduction in system pressure.
What else must be present for - Correct Answers -an opening to atmosphere

Which of the following may cause backpressure backflow? - Correct Answers -any of
the above (elevated piping, pumps, hot water tanks)

, A direct cross-connection is subject to - Correct Answers -both backsiphonage and
backpressure
A column of water exerts pressure at the bottom of the column due to the - Correct
Answers -weight of the water in the column

If the gauge pressure in a water pipe is negative, this means that exists - Correct
Answers -a vacuum

The BAT must complete a test report form acceptable to the local water purveyor -
Correct Answers -after every test of an approved backflow prevention assembly or
inspection of an approved air gap

The results of a test of an approved backflow prevention assembly must be reported to
the water purveyor on a form acceptable to - Correct Answers -the purveyor

An approved air gap is a physical separation between - Correct Answers -the end of the
potable water supply pipe and the overflow rim of the receiving vessel, a distance of at
least 2 times supply pipe diameter and never less than 1"

An approved air gap is acceptable as backflow protection for - Correct Answers -
Backpressure as well as Backsiphonage and both High and Low Health Hazard

An approved backflow prevention assembly is an RPBA, RPDA, DCVA, DCDA, PVBA,
or SVBA of make, model and size that is - Correct Answers -approved by the
Washington State DOH, ODW

Newly installed backflow assemblies have a initial test primarily due to: high rate of
failure at the time of the - Correct Answers -debris from within the supply piping

If a customer requires continuous water service it is recommended that - Correct
Answers -a parallel set of backflow assemblies appropriate for the degree of hazard be
installed

The shut off valves used on approved Backflow Prevention assemblies must always be
- Correct Answers -resilient seated

An approved backflow prevention assembly must be installed in such a manner that -
Correct Answers -it will not become flooded and with adequate space around the
assembly to facilitate testing and maintenance

An RPBA must not be installed where - Correct Answers -all of the above (water spilt
from the assembly will be objectionable, the assembly will become flooded, the
assembly is more than 60 inches above the floor or ground)

Geschreven voor

Instelling
BACKFLOW
Vak
BACKFLOW

Documentinformatie

Geüpload op
21 juli 2025
Aantal pagina's
7
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$12.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Gordones22 Yala university
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
502
Lid sinds
4 jaar
Aantal volgers
351
Documenten
9499
Laatst verkocht
3 dagen geleden

4.1

108 beoordelingen

5
63
4
17
3
13
2
4
1
11

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen