Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

CWB Welding Inspection Level II - Chapter 10 Radiographic Inspection | Exam Q-Bank | Actual Questions & Certified Solutions | Complete Accurate Quizzes with Verified Answers, .

Rating
5.0
(2)
Sold
-
Pages
76
Grade
A+
Uploaded on
22-07-2025
Written in
2024/2025

CWB Welding Inspection Level II - Chapter 10 Radiographic Inspection | Exam Q-Bank | Actual Questions & Certified Solutions | Complete Accurate Quizzes with Verified Answers, . Terms in this set (165) _____________Quiz____________? Which of the following are disadvantages of gamma rays over X-ray radiography? Select all that apply: Radiation emitted continuously High maintenance Radioisotope requires replacement Higher initial cost Option 1 & 2 Option 2 & 3 Option 1 & 3 - Answer Option 1 & 3 _____________Quiz____________? Which organization in Canada controls the use of gamma ray devices? Canadian Nuclear Association for Safety Canadian Nuclear Safety Commission (CNSC) International Atomic Energy Agency Atomic Energy of Canada Limited (AECL) - Answer Canadian Nuclear Safety Commission (CNSC) _____________Quiz____________? The only thing that causes fuzziness at the edge of an image is geometric unsharpness. True False - Answer False _____________Quiz____________? The purpose of the IQI is to verify that all defects greater than 2% of the plate thickness have been detected . True False - Answer False _____________Quiz____________? If a product is to be stress relieved, why is it important to use exactly the same procedure for radiography after stress relief as is used before? Because the image will appear distorted after heat treatment To prevent borderline indications that could be interpreted differently before and after stress relief The film will burn up during heat treatment To improve the image - Answer To prevent borderline indications that could be interpreted differently before and after stress relief _____________Quiz____________? According to CSA W59, when doing spot radiography what minimum length of weld must each spot show? 100 mm

Show more Read less
Institution
CWB Welding Inspection Level II
Course
CWB Welding Inspection Level II

Content preview

CWB Welding Inspection Level II -
Chapter 10 Radiographic Inspection |
Exam Q-Bank | Actual Questions &
Certified Solutions | Complete Accurate
Quizzes with Verified Answers, 2025-
2026.
Terms in this set (165)



_____________Quiz____________?

Which of the following are disadvantages of gamma rays over X-ray radiography? Select all that

apply:



Radiation emitted continuously

High maintenance

Radioisotope requires replacement

Higher initial cost

Option 1 & 2

Option 2 & 3

Option 1 & 3 -

Answer✓✓

Option 1 & 3



1

,_____________Quiz____________?

Which organization in Canada controls the use of gamma ray devices?



Canadian Nuclear Association for Safety

Canadian Nuclear Safety Commission (CNSC)

International Atomic Energy Agency

Atomic Energy of Canada Limited (AECL) -

Answer✓✓

Canadian Nuclear Safety Commission (CNSC)



_____________Quiz____________?

The only thing that causes fuzziness at the edge of an image is geometric unsharpness.



True

False -

Answer✓✓

False



_____________Quiz____________?

The purpose of the IQI is to verify that all defects greater than 2% of the plate thickness have

been detected .




2

,True

False -

Answer✓✓

False



_____________Quiz____________?

If a product is to be stress relieved, why is it important to use exactly the same procedure for

radiography after stress relief as is used before?



Because the image will appear distorted after heat treatment

To prevent borderline indications that could be interpreted differently before and after stress

relief

The film will burn up during heat treatment

To improve the image -

Answer✓✓

To prevent borderline indications that could be interpreted differently before and after stress

relief



_____________Quiz____________?

According to CSA W59, when doing spot radiography what minimum length of weld must each

spot show?



100 mm


3

, 200 mm

50 mm

75 mm -

Answer✓✓

100 mm



_____________Quiz____________?

The emission of gamma rays from a radioactive isotope cannot be switched off; the source can

only be retracted into a shielding container.



True

False -

Answer✓✓

True



_____________Quiz____________?

Which of the following are some items you would look for when checking a procedure for

radiography? Select all that apply:



Type of electrode used

Type of source

Geometric arrangement

Source-to-film distance -


4

Written for

Institution
CWB Welding Inspection Level II
Course
CWB Welding Inspection Level II

Document information

Uploaded on
July 22, 2025
Number of pages
76
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$13.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF


Also available in package deal

Reviews from verified buyers

Showing all 2 reviews
10 months ago

10 months ago

5.0

2 reviews

5
2
4
0
3
0
2
0
1
0
Trustworthy reviews on Stuvia

All reviews are made by real Stuvia users after verified purchases.

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Exampage Chamberlain College Of Nursing
Follow You need to be logged in order to follow users or courses
Sold
6033
Member since
2 year
Number of followers
19
Documents
1636
Last sold
3 days ago
Studying Nursing & Other Courses❓ Shop the most resent doc's here, at BEST Prices And race Against time❤️

We are trusted experienced professional experts working as study material sourcing agents, We offer authentic & meticulously crafted exam papers, directly sourced from reputable institutions, Our papers serve as invaluable tools to aid aspiring nurses and many other professions in their exam preparations. STUDY LESS STUDY SMART

4.5

2020 reviews

5
1178
4
621
3
183
2
29
1
9

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions