G2 EXAM PREP 2025 NEWEST
QUESTIONS AND DETAILED CORRECT
ANSWERS | A+ GRADE VERIFIED
ANSWERS

When sizing capacitors in series, what would be the total
capacitance with 12MFD and 15MFD capacitors?
A. 5.66
B. 6.35
C. 6.97
D. 6.66 Correct Answer D. 6.66 CT = C1 x C2 / C1 + C2

What would be the BTU output of a 10 KW heater
A. 38210
B. 36220
C. 33150
D. 34120 Correct Answer D. 34120

Clocking a 5 foot dial on a gas meter for 63 seconds, what
would be the appliance input?
A. 258,000 BTU
B. 286,000 BTU
C. 268,000 BTU
D. 284,OOO BTU Correct Answer B. 286,000 BTU

What is the sole purpose of an EAC?
A. To remove dirt, humidity and odours.
B. To remove dust, dirt and smoke.
C. To remove humidity from the air.

,D. To remove smoke, dirt and odours Correct Answer B.
To remove dust, dirt and smoke.

What does a gas pressure regulator control?
A. Controls inlet pressure.
B. Controls gas flow.
C. Controls downstream pressure.
D. Locks out gas flow. Correct Answer C. Controls
downstream pressure.

A first stage or high pressure regulator reduces tank
pressure to...?
A. 350 to 10 PSI
B. 375 to 5 PSI
C. 250 to 10 PSI
D. 375 to 10 PSI Correct Answer C. 250 to 10 PSI

On a regulator what measures outlet pressure?
A. Restricting element.
B. Measuring element.
C. Loading element.
D. Spring element. Correct Answer B. Measuring element.

Which gas meter would be used for a small or mid size
commercial installation?
A. Rotary type.
B. Tubing type.
C. Bellow type.
D. Orifice. Correct Answer C. Bellow type.

A fan assist burner is?

,A. Designed for better combustion.
B. Designed for conversion boiler.
C. Designed to overcome appliance friction.
D. Designed to overcome burner friction. Correct Answer
D. Designed to overcome burner friction.

A propane service regulator would normally deliver
pressure at?
A. Pound to 11" wc
B. Ounces to 7" wc
C. Ounces to 11" wc
D. Pound to 7" wc Correct Answer A. Pound to 11" wc

What monitors water flow in a pool heater?
A. Aqua stat
B. Low water cut off
C. Pressure control
D. Flow switch Correct Answer C. Pressure control

A commercial forced air furnace transfers heat in what
medium?
A. Conductive
B. Thermal
C. Convective
D. Radiant Correct Answer C. Convective

Venting spillage can be caused by?
A. Improper combustion air mixture.
B. Excessive elbows in venting system.
C. Cracked heat exchanger.

, D. Blocked condensate furnace drain.0 Correct Answer B.
Excessive elbows in venting system.

When venting spillage occurs and flue gases passes back
through combustion zones what change occurs?
A. Flue gases are hotter and rise faster through chimney.
B. Flue CO2 gases are more efficient.
C. Flue CO2 gases changes to N2.
D. Flue CO2 gases changes to CO. Correct Answer D.
Flue CO2 gases changes to CO.

For a free standing propane range in a large kitchen the
flexible connector may be how long?
A. 10'
B. 6'
C. 4'
D. 8' if range is in the center of the kitchen Correct Answer
B. 6'

An inverted sensor can be found operating what type of
appliances?A. Hot water boiler.
B. Steam water boiler.
C. Domestic hot water storage tank.
D. Domestic potable hot water tank Correct Answer D.
Domestic potable hot water tank

A propane service regulator would normally deliver
pressure at?
A) Pound to 11" wc
B. Ounces to 7" wc
C. Ounces to 11" wc

Geschreven voor

Instelling
G2 gas texh
Vak
G2 gas texh

Documentinformatie

Geüpload op
22 juli 2025
Aantal pagina's
34
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$23.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
TUTORWAC Johns Hopkins University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
362
Lid sinds
2 jaar
Aantal volgers
115
Documenten
3595
Laatst verkocht
5 dagen geleden
TUTORWAC

BEST HOMEWORK HELP AND TUTORING ON YOUR QUIZZES AND EXAMS WITH GUARANTEE OF EXCELLENT GRADES

4.1

55 beoordelingen

5
32
4
9
3
7
2
3
1
4

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen