Michigan Builders License Exam 2026
Questions and Answers
Created to serve as a complete, comprehensive code regulating the construction of
single-family, two-family and buildings consisting of three or more townhouse
units. - Correct Answer-IRC (International Residential Code)
Administrative - Correct Answer-First 2 chapters of code book are
True - Correct Answer-Plans or supporting documents are almost always required
by the controlling authority prior to issuing a permit. T or F
Yes - Correct Answer-Does the building official have the authority to render
interpretations of the code?
8 foot fence. - Correct Answer-None of the following require a permit, EXCEPT:
sidewalks and driveways
tiling
an 8 foot fence
playground equipment
©COPYRIGHT2025, ALL RIGHTS RESERVED 1
,False - Correct Answer-Tables and illustrations are always supported by
information found in the written code and footnotes. T or F
Live load. - Correct Answer-The amount of evenly distributed weight imposed by
inhabitants, goods and removable objects on a floor or roof system is referred to as
True. - Correct Answer-If a code requirement is in the book, it is both acceptable
and enforceable by the code official. T or F
Figures. - Correct Answer-Illustrations are typically referred to as
Determine that buildings are built to the minimum enforceable standard. - Correct
Answer-Generally speaking, the building official's job is to
True. - Correct Answer-It is required that all manufacturer instructions be at the
jobsite at the time of inspection. T or F
Kitchen. - Correct Answer-All of the following are not considered habitable spaces
EXCEPT:
bathrooms
kitchens
storage spaces
closets
©COPYRIGHT2025, ALL RIGHTS RESERVED 2
,3. - Correct Answer-Bathrooms must be provided with an aggregate glazing area
no less than _____ square feet, half of which must be openable.
44 inches. - Correct Answer-The maximum height of an egress window above the
floor is
5.7 sq ft. - Correct Answer-A basement bedroom must have an egress window with
a clear opening of at least ______ square feet.
3. - Correct Answer-At least one side-hinged exit door must be in each dwelling
unit, and must be _____ feet wide.
30 inches. - Correct Answer-A porch more than _____ inches above grade must be
provided with 36" guards.
200. - Correct Answer-Wall and ceiling finishes shall have a flame-spread
classification of no more than ______ .
7 days. - Correct Answer-According to code, concrete must reach at least 70% of
it's ability within ____________days.
40%. - Correct Answer-A stud used for a non-bearing partitions may not be
notched more than ____% of the stud width.
Additions, alterations, renovation and repairs. - Correct Answer-The Michigan
Uniform Energy code applies to new buildings as well as
©COPYRIGHT2025, ALL RIGHTS RESERVED 3
, U-factor. - Correct Answer-___________ is a measure of how well the window or
door assembly conducts heat. The lower the number, the better insulation the
assembly will provide.
50%. - Correct Answer-Energy losses from recessed lighting fixtures can often
reach ___% of the total thermal loss of a ceiling.
R-3. - Correct Answer-Michigan requires a minimum thermal resistance of
____________for mechanical system piping.
True. - Correct Answer-Oversized HVAC equipment has a higher initial cost, a
higher operating cost, provides less comfort, and shorter life expectancy. T or F
Prescriptive Path. - Correct Answer-_______ is the compliance route that applies
Table 402.1.1 to building envelope components, and is considered the most simple.
Area weighted averages. - Correct Answer-___________ can be used to satisfy U-
factor and SHGC requirements.
IC (Insulation Contact) - Correct Answer-Recessed lights must be _____ rated.
True. - Correct Answer-Up to 15 square feet of glazing per dwelling unit is
exempted from U-value requirements. T or F
©COPYRIGHT2025, ALL RIGHTS RESERVED 4
Questions and Answers
Created to serve as a complete, comprehensive code regulating the construction of
single-family, two-family and buildings consisting of three or more townhouse
units. - Correct Answer-IRC (International Residential Code)
Administrative - Correct Answer-First 2 chapters of code book are
True - Correct Answer-Plans or supporting documents are almost always required
by the controlling authority prior to issuing a permit. T or F
Yes - Correct Answer-Does the building official have the authority to render
interpretations of the code?
8 foot fence. - Correct Answer-None of the following require a permit, EXCEPT:
sidewalks and driveways
tiling
an 8 foot fence
playground equipment
©COPYRIGHT2025, ALL RIGHTS RESERVED 1
,False - Correct Answer-Tables and illustrations are always supported by
information found in the written code and footnotes. T or F
Live load. - Correct Answer-The amount of evenly distributed weight imposed by
inhabitants, goods and removable objects on a floor or roof system is referred to as
True. - Correct Answer-If a code requirement is in the book, it is both acceptable
and enforceable by the code official. T or F
Figures. - Correct Answer-Illustrations are typically referred to as
Determine that buildings are built to the minimum enforceable standard. - Correct
Answer-Generally speaking, the building official's job is to
True. - Correct Answer-It is required that all manufacturer instructions be at the
jobsite at the time of inspection. T or F
Kitchen. - Correct Answer-All of the following are not considered habitable spaces
EXCEPT:
bathrooms
kitchens
storage spaces
closets
©COPYRIGHT2025, ALL RIGHTS RESERVED 2
,3. - Correct Answer-Bathrooms must be provided with an aggregate glazing area
no less than _____ square feet, half of which must be openable.
44 inches. - Correct Answer-The maximum height of an egress window above the
floor is
5.7 sq ft. - Correct Answer-A basement bedroom must have an egress window with
a clear opening of at least ______ square feet.
3. - Correct Answer-At least one side-hinged exit door must be in each dwelling
unit, and must be _____ feet wide.
30 inches. - Correct Answer-A porch more than _____ inches above grade must be
provided with 36" guards.
200. - Correct Answer-Wall and ceiling finishes shall have a flame-spread
classification of no more than ______ .
7 days. - Correct Answer-According to code, concrete must reach at least 70% of
it's ability within ____________days.
40%. - Correct Answer-A stud used for a non-bearing partitions may not be
notched more than ____% of the stud width.
Additions, alterations, renovation and repairs. - Correct Answer-The Michigan
Uniform Energy code applies to new buildings as well as
©COPYRIGHT2025, ALL RIGHTS RESERVED 3
, U-factor. - Correct Answer-___________ is a measure of how well the window or
door assembly conducts heat. The lower the number, the better insulation the
assembly will provide.
50%. - Correct Answer-Energy losses from recessed lighting fixtures can often
reach ___% of the total thermal loss of a ceiling.
R-3. - Correct Answer-Michigan requires a minimum thermal resistance of
____________for mechanical system piping.
True. - Correct Answer-Oversized HVAC equipment has a higher initial cost, a
higher operating cost, provides less comfort, and shorter life expectancy. T or F
Prescriptive Path. - Correct Answer-_______ is the compliance route that applies
Table 402.1.1 to building envelope components, and is considered the most simple.
Area weighted averages. - Correct Answer-___________ can be used to satisfy U-
factor and SHGC requirements.
IC (Insulation Contact) - Correct Answer-Recessed lights must be _____ rated.
True. - Correct Answer-Up to 15 square feet of glazing per dwelling unit is
exempted from U-value requirements. T or F
©COPYRIGHT2025, ALL RIGHTS RESERVED 4