This document is a complete exam preparation resource for the AWWA Cross-Connection Control Specialist Exam 1. It contains dozens of multiple-choice questions with correct answers and detailed explanations. Topics covered include backflow types (backsiphonage, backpressure), cross-connection hazards, backflow prevention devices (RPZ, DCVA, PVB, AVB), installation standards, testing procedures, and health hazard classifications (low vs. high hazard). Ideal for certification candidates and professionals involved in water safety, plumbing compliance, and municipal systems.

Show more Read less
Institution
Backflow Certification
Course
Backflow certification

Content preview

AWWA (American Water Works Association) Cross
Connection Control Specialist exam 1 questions with
accurate answers
1. What is the primary purpose of a cross-connection control program?
A) To reduce water consumption
B) To prevent contamination of the potable water supply
C) To improve water pressure
D) To reduce water treatment costs Ans✓✓✓ B) To prevent
contamination of the potable water supplyExplanation: The main goal of
a cross-connection control program is to protect the public water system
from potential contamination due to backflow.


10. Which of the following is NOT a common type of backflow
prevention device?
A) Pressure vacuum breaker (PVB)
B) Reduced pressure zone (RPZ) valve
C) Double check valve (DCV)
D) Flow restrictor valve Ans✓✓✓ D) Flow restrictor valve


11. Which of the following types of backflow prevention devices would
be appropriate for a high-hazard system where both backsiphonage and
backpressure are possible?
A) Double Check Valve Assembly (DCVA
B) Pressure Vacuum Breaker (PVB)
C) Reduced Pressure Zone (RPZ) Valve

, D) Atmospheric Vacuum Breaker (AVB) Ans✓✓✓ C) Reduced
Pressure Zone (RPZ) Valve


12. What should be done if there is no accessible shut-off valve before
the backflow prevention device in a system?
A) The backflow preventer should be installed anyway, as it is the most
important part of the system.
B) A shut-off valve should be installed before the backflow preventer.
C) The system should be left without a shut-off valve and rely solely on
the backflow preventer.
D) The backflow preventer can be installed at any point in the system,
regardless of the shut-off valve location. Ans✓✓✓ B) A shut-off valve
should be installed before the backflow preventer.


13. Which type of backflow prevention device is required for an
irrigation system that uses chemical additives?
A) Atmospheric Vacuum Breaker (AVB)
B) Double Check Valve Assembly (DCVA)
C) Reduced Pressure Zone (RPZ) Valve
D) Pressure Vacuum Breaker (PVB) Ans✓✓✓ C) Reduced Pressure
Zone (RPZ) Valve


14. Which of the following is NOT a factor in determining the hazard
level of a cross-connection?
A) The potential health risk posed by the substance in the system.
B) The location of the cross-connection in the water distribution system.

Written for

Institution
Backflow certification
Course
Backflow certification

Document information

Uploaded on
July 26, 2025
Number of pages
15
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$20.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Reviews from verified buyers

Showing all 2 reviews
3 days ago

7 months ago

4.5

2 reviews

5
1
4
1
3
0
2
0
1
0
Trustworthy reviews on Stuvia

All reviews are made by real Stuvia users after verified purchases.

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
cracker Chamberlain School Of Nursing
Follow You need to be logged in order to follow users or courses
Sold
2130
Member since
3 year
Number of followers
1347
Documents
49950
Last sold
2 days ago
✨ Cracker – Verified Study Powerhouse

Welcome to your shortcut to academic and certification success. I'm Cracker, a trusted top seller I specialize in high-quality study guides, test banks, certification prep, and real-world exam material all tailored to help you pass fast and score high.

3.8

386 reviews

5
169
4
90
3
54
2
24
1
49

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions