At what point does the FVD audibly tone? Correct Answers 50
volts
How can you bond to mobile homes? Correct Answers You
can bond to the mobile home itself if needed.
How do you revert the SSID and password of a router to the
factory settings? Correct Answers A hard reset, pinhole in the
back of the router
How far above a public highway or interstate does our drop have
to be? Correct Answers 18'
How far above a public road does our drop have to be? Correct
Answers 15'6"
How far above a residential driveway does our drop have to be?
Correct Answers 11'6"
How far above a residential walkway does our drop have to be?
Correct Answers 9'6"
How far does a Q-clamp have to be from the center of the pole?
Correct Answers 24"
How far does a Q-clamp have to be from the tap? Correct
Answers 6"
How is an ISA splitter powered? Correct Answers Phone port
, Ohm's Law Equation for RG-11 Correct Answers 16.1Ω per
1000ft; .0161Ω per foot
Ohm's Law Equation for RG-6 Correct Answers 34.1Ω per
1000ft; .0341Ω per foot
What are the 4 bonding methods in order from most to least
preferred? Correct Answers 1. To the Intersystem Bonding
Terminal
2. To the electric service bonding rod
3. To a metal conduit with a bond wrap
4. To the meter box with a clamp
What are the length ranges for all types of Coax? Correct
Answers RG-6 is used for 1-150ft installs
RG-11 is used for 151-250ft installs
Flex-500 is used for 251-400ft installs and requires supervisor
approval
What color tags are required for a working, active tap? Correct
Answers White address tags and White Active Service tags
What does an alarm system require when setting up phone lines?
Correct Answers Line seizure, meaning that if the alarm is
tripped, all phones will be terminated and 911 will be called
automatically
What does HFC stand for? Correct Answers Hybrid Fiber Coax