Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

TFM Fire Extinguisher Rule/Statues and Codes Test | Questions and Answers | 100 out of 100 | GRADEDA | Latest 2025/ 2026 update

Beoordeling
-
Verkocht
-
Pagina's
11
Cijfer
A+
Geüpload op
05-08-2025
Geschreven in
2025/2026

TFM Fire Extinguisher Rule/Statues and Codes Test | Questions and Answers | 100 out of 100 | GRADEDA | Latest 2025/ 2026 update Question: Fire Extinguishers that are water based shall not be considered a class "C" if the extinguisher has a conductivity higher than? Answer: 1.00 µS/cm at 25°C (77°F) Question: Environments containing oxidizers shall be equipped with what type of extinguishing agent? Answer: Water Question: A hand portable fire extinguisher shall be installed so that the clearance between the floor and the bottom of the fire extinguisher shall be? Answer: 4 in. Question: Fire extinguisher cabinets shall not be locked under any circumstance? True or False? Answer: False, they may be locked if they are subject to malicious use but they must have a key accessible on top of the cabinet. Question: Firm Answer: Individual, partnership, corporation, or association. Question: Registered Firm Answer: A "Firm" that holds a registration Question: The maximum required insurance for bodily injury must be? Answer: 100,000$ Question: The Fire Marshall has how many days to inform you of your testing results if the test is issued by a testing service? Answer: 14 days. Question: How long does the Fire Marshall have to inform you of your testing results if there is a delay? 90 days Answer: Question: If the test is taken underneath a chapter how long does the Fire Marshall have to notify you of your testing results? Answer: 30 days Question: When does an apprentice permit expire? Answer: On the anniversary of the date of issuance. Question: How many days does the State Fire Marshall have to notify you of impending expiration of your license? Answer: 30 days. Question: A firm or individual whose license has been expired up to 90 days is required to pay. Answer: The required renewal fee plus half of the initial fee of the registration or certificate. Question: A firm or individual whose license has been expired for more than 90 days, but less than 2 years is required to pay what fees? Answer: 1) all unpaid renewal fees 2) a fee that is equal to the initial fee of the registration or certificate. Question: What does Section 6001.253 allow? Answer: The commissioner to suspend, revoke, or refuse to issue or renew a certificate, license, permit, or approval. Question: Any licensee who has had there license or certificate revoked must to what to have it reinstated? Answer: Re-take the required test. Question: Any offense under the 28 TAC §§34.500 (Fire Extinguisher Insurance Codes) can be considered what class of crime? Answer: Class B misdemeanor. Question: How long do you have to notify the State Fire Marshall of a complete change of ownership? Answer: 14 days. Question: How long do you have to notify the State Fire Marshall of a change of corporate offices? Answer: 14 days. Question: How long do you have to notify the State Fire Marshall of a change of a Firm's name, location, or mailing address? Answer: 14 days Question: Type PL license can preform which task? Answer: planning, supervising, certifying, installing, or servicing of all fixed fire systems other than pre-engineered systems. Question: Type A license can preform which task? Answer: certify, or service the instillation of all fixed fire extinguisher systems. Question: Type B license can preform which task? Answer: servicing, certifying, and low pressure hydrostatic testing of portable fire extinguishers. Question: Type K license can preform which task? Answer: installing, certifying, or servicing of pre-engineered fixed fire extinguisher systems for the protection of cooking areas. Question: Type R license can preform which task? Answer: installing, certifying, or servicing of pre-engineered fixed residential range top fire extinguisher systems. Question: Pocket license Answer: a licensee must carry a pocket license for identification for identification. Question: Duplicate license Answer: must be obtained from the state fire marshal to replace a lost or destroyed license. Question: How many days do you have to notify the state fire marshal of the change of firm or mailing address under which you operate as a licensee? Answer: 14 days Question: How any days does a firm have to notify the state fire marshal of the termination of an employee? Answer: 14 days Question: Which license must you have for 6 months prior to applying for a type A or K license? Answer: Type B. Question: Which two forms of technical qualification must you have to apply for a type PL license? Answer: 1) Proof of registration in Texas as a professional engineer. 2) A copy of NICET's notification letter regarding the applicant's successful completion of Level III special hazards. Question: What date and time will your license expire? Answer: 12:00 midnight on the date printed on your license Question: How long do you have to revise any errors on your application for renewal on a license before a late-fee may be charged. Answer: 30 days. Question: All shop drawings must bear what? Answer: The signature of a type PL license. Question: What is considered a high-pressure cylinder? Answer: A cylinder with a pressurized gas of higher than 500 psi. Question: What is considered a low-pressure cylinder? Answer: A cylinder with a pressurized gas of lower than 500 psi. Question: How many AFFF or FFFP fire extinguishers of at least 2½ gallons are required to fulfill an extra hazard requirement? Answer: 3. Question: How many AFFF or FFFP fire extinguishers of at least 1.6 gallons are required to meet ordinary hazard requirements? Answer: 2. Question: What is the maximum travel distance for a Class K hazard? Answer: No more than 30 ft. Question: What is the maximum travel distance for a Class D hazard? Answer: No more than 75 ft. Question: Where hand portable fire extinguishers are installed for 3-D ds what is the maximum travel distance? Answer: No more 30 ft. Question: Where wheeled fire extinguishers (125 lbs extinguishing agent) are installed for 3-D fire hazards what is the maximum travel distance? Answer: No more than 100

Meer zien Lees minder
Instelling
TFm Extinguisher
Vak
TFm extinguisher

Voorbeeld van de inhoud

TFM Fire Extinguisher Rule/Statues and Codes
Test | Questions and Answers | 100 out of 100 |
GRADEDA | Latest 2025/ 2026 update

Question:
Fire Extinguishers that are water based shall not be considered a class "C" if the extinguisher has
a conductivity higher than?

Answer:
1.00 µS/cm at 25°C (77°F)




Question:
Environments containing oxidizers shall be equipped with what type of extinguishing agent?

Answer:
Water




Question:
A hand portable fire extinguisher shall be installed so that the clearance between the floor and
the bottom of the fire extinguisher shall be?

Answer:
4 in.




Question:
Fire extinguisher cabinets shall not be locked under any circumstance? True or False?

Answer:

, False, they may be locked if they are subject to malicious use but they must have a key
accessible on top of the cabinet.




Question:
Firm

Answer:
Individual, partnership, corporation, or association.




Question:
Registered Firm

Answer:
A "Firm" that holds a registration




Question:
The maximum required insurance for bodily injury must be?

Answer:
100,000$




Question:
The Fire Marshall has how many days to inform you of your testing results if the test is issued by
a testing service?

Answer:

Geschreven voor

Instelling
TFm extinguisher
Vak
TFm extinguisher

Documentinformatie

Geüpload op
5 augustus 2025
Aantal pagina's
11
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$11.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
EliteStudyDocs Rasmussen College
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
3559
Lid sinds
5 jaar
Aantal volgers
2868
Documenten
9036
Laatst verkocht
3 dagen geleden
High Quality Exams, Study guides, Reviews, Notes, Case Studies

Welcome to EliteStudyDocs, your ultimate destination for high-quality, verified study materials trusted by students, educators, and professionals across the globe. I specialize in providing A+ graded exam files, practice questions, complete study guides, and certification prep tailored to a wide range of academic and professional fields. P/S: CHECK OUT THE PACKAGE DEALS

4.0

697 beoordelingen

5
383
4
127
3
77
2
39
1
71

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen