Alabama Gas Test Exam COMPLETE QUESTIONS
AND ANSWERS | ALREADY PASSED | 2025
LATEST!!
Save
Terms in this set (342)
The ____ shall be owner or owner agents- 102.3 Maintenance
responsible for the
maintenance of fuel gas
installations.
If the permit has not been 180 days-106.3.2 Time limitation of application
issued, an application for a
permit is considered
abandoned _____ days after
the date of filing.
The lowest portion of a 18-609.4 Clearance
floor furnace shall have 12
inch minimum clearance
on all sides except the
control side, which shall
have a ____ minimum
clearance.
https://quizlet.com/1064166836/alabama-gas-test-exam-complete-questions-and-answers-already-passed-2025-latest-flash-cards/?new 1/61
,8/6/25, 6:58 AM Alabama Gas Test Exam COMPLETE QUESTIONS AND ANSWERS | ALREADY PASSED | 2025 LATEST!! Flashcards | Quizlet
Water heaters utilized I.P.C. International Plumbing code- 624.2 Water
both to supply potable heaters used for space heating
water and provide hot
water for space heating
shall be listed and labeled
and shall be installed in
accordance with the _____.
A drip shall not be be Freezing-408.3 Location of drips
located where
condensate is subject to
____.
A means to interrupt the Within Sight and 50 feet- 627.10 switches in electrical
electrical supply to an air supply
conditioning appliance
shall be provided ____ and
not more than ___ feet from
the air conditioner.
Floor furnaces shall not in a concrete floor built on grade.-609.2 #4 Placement
be installed _____
A yellow insulated copper Adjacent-404.15.3 tracer
tracer wire or other
approved conductor shall
be installed ____ to the
underground nonmetallic
gas piping.
The floor register of a 12 inches from the draperies-609.2 #3 placement
floor furnace is permitted
to be installed ____
Casing extension boots listed as a part of the appliance.-608.5 ducts
shall not be installed on a prohibited
wall furnace unless __
https://quizlet.com/1064166836/alabama-gas-test-exam-complete-questions-and-answers-already-passed-2025-latest-flash-cards/?new 2/61
,8/6/25, 6:58 AM Alabama Gas Test Exam COMPLETE QUESTIONS AND ANSWERS | ALREADY PASSED | 2025 LATEST!! Flashcards | Quizlet
Outside ventilation air 4-612.5 air supply
shall be supplied to the
space containing a
recirculating direct fired
industrial heater at a
minimum rate of _ com per
1,000 but/h of the rated
input of the heater.
Clothes dryer exhaust backdraft damper- 614.4 exhaust installation
ducts shall be equipped
with a ___
Vented wall furnaces shall fire hazard- 608.3 location
be located so as not to
cause a ___ to walls floors
combustible furnishings or
doors.
Non recirculating direct sleeping quarters-611.2 installation
fired industrial air heaters
shall not be used to
supply any area containing
___
dryer exhaust systems outside of the building 614.1 installation
shall be independent of all
other systems and shall
convey the moisture and
any products of
combustion to the
dryer ducts shall not be sheet metal screws 614.4 exhaust installation
connected or installed
with ___ or other fasteners
that will obstruct the flow.
https://quizlet.com/1064166836/alabama-gas-test-exam-complete-questions-and-answers-already-passed-2025-latest-flash-cards/?new 3/61
, 8/6/25, 6:58 AM Alabama Gas Test Exam COMPLETE QUESTIONS AND ANSWERS | ALREADY PASSED | 2025 LATEST!! Flashcards | Quizlet
where space for a exhaust duct 614.6.7 exhaust duct required
domestic clothes dryer is
provided an ______ system
shall be installed
the minimum 2-618.2 forced air furnaces
unobstructed total area of
the outside and return air
ducts or openings to a
forced air warm air
furnace shall be not less
than __ square inches per
1,000 btu/h output rating
capacity of the furnace
in general return air for a Crawl space-618.5 #7 prohibited sources
forced air furnace shall
not be taken from a ____
the required ventilation 4 and 8- 615.7 sauna room
opening to a sauna room
shall not be less than _
inches by _ inches
suana heaters shall be 194 degrees-615.6 heat and time controls
equipped with a
thermostat that limits the
room temp to no more
than ___ degrees
Fahrenheit
required outdoor air inlets 1/4 inch-618.6 screen
for a residential forced air
heating system shall be
covered with screen
having _ inch openings
https://quizlet.com/1064166836/alabama-gas-test-exam-complete-questions-and-answers-already-passed-2025-latest-flash-cards/?new 4/61