Questions and Answers A+ Graded
What .are .the .core .chapters .of .NFPA .101 .- .CORRECT .ANSWER-chpt .1-10 .and
.chpt .43
which .chapter .describes .the .requirements .for .special .structures .- .CORRECT
.ANSWER-chpt .11
describe .NFPA .101 .Life .Safety .code .- .CORRECT .ANSWER-Occupany
.classification .and .Rehabilitation .work .categories, .hazard .of .contents, .stories .in
.height .and .construction .type
what .is .the .content .of .chapter .1 .of .NFPA .101 .- .CORRECT .ANSWER-Scope,
.Purpose, .Application, .Equivalency, .Units .& .Formulas, .Enforcements
What .is .the .content .of .chapter .2 .of .NFPA .101 .- .CORRECT .ANSWER-Referenced
.Publication .(General, .NFPA .Publications, .other .Publication, .References .of
.Extracts .in .Mandatory .Sections
What .is .the .content .of .Chapter .3 .- .CORRECT .ANSWER-General, .Official
.Definition, .General .Definition
What .is .the .content .of .Chapter .4 .- .CORRECT .ANSWER-General/Requirements
What .is .the .content .of .Chapter .5 .- .CORRECT .ANSWER-Performance .based
.options
What .is .the .content .of .chapter .6 .- .CORRECT .ANSWER-Classification .of
.occupancy/hazard .of .contents
What .is .the .content .of .chapter .7 .- .CORRECT .ANSWER-Minimum .Requirement
.of .Egress
What .is .the .content .of .Chapter .8 .- .CORRECT .ANSWER-Minimum .Requirement
.of .Fire .protection .(construction .type, .compartmentation, .fire .barriers, .smoke
.partitions .and .smoke .barriers
, what .is .the .content .of .chapter .9 .- .CORRECT .ANSWER-covers .two .systems
.commonly .found .in .buildings .(building .services, .and .fire .protection .equipment)
.HVAC, .elevators, .escalator .and .rubbish .chutes
what .is .the .content .of .chapter .10 .- .CORRECT .ANSWER-min .requirements .of
.interior .finishes, .contents .and .furnishings
what .is .the .content .of .chapter .11 .- .CORRECT .ANSWER-cover .special .structures
.(high .rise .buildings) .other .code .pervisions .applied .to .this .chapter
what .is .the .content .of .chapter .43 .- .CORRECT .ANSWER-provisions .for
.performing .rehabilitation .work .in .existing .buildings .without .requiring .all
.rehabilitation .work
Code .organization: .Even .and .odd .numbers .- .CORRECT .ANSWER-even .for .new
.occupancy, .odd .for .existing .occupancy. .some .chapters .are .for .both .new .and
.existing .such .as .(chapter .24, .26, .40 .and .42)
what .is .the .suggested .procedure .for .applying .the .code .requirements .(step .1-9)
.- .CORRECT .ANSWER-1- .Determine .the .occupancy .classification .by .referencing
.the .definitions .in .chapter .6 .
2- .New .or .Existing .Structure .
3- .Occupant .load
4- .Hazard .of .Contents .
5- .Reference .to .the .occupancy .chapter .12-42
6- .Sub-classification .or .special .use .condition .
7- .Proceed .thru .applicable .chapter
8- .Two .or .more .requirement .-- .refer .to .the .occupancy .chapter .which .is
.generally .takes .precedence
9- .apply .requirement .for .special .structures .if .applicable
What .is .the .Scope .of .the .Life .Safety .Code .NFPA .101 .- .CORRECT .ANSWER-
Minimize .danger .to .life .from .effects .of .fire .including .smoke, .heat .and .toxic
.gases .created .during .fire
What .is .the .Purpose .of .Life .Safety .Code .NFPA .101 .- .CORRECT .ANSWER-
Minimum .requirement .for .Safety .to .Life .from .fire
What .does .Smoulding .mean .- .CORRECT .ANSWER-burn .slow .with .smoke, .but
.no .smoke
What .are .the .three .classification .of .hazard .of .contents, .and .where .can .you .find
.them .in .the .code .- .CORRECT .ANSWER-1- .low .
2- .ordinary
3- .high .
(can .be .found .in .6.2)
what .is .LED? .and .its .definition .- .CORRECT .ANSWER-Level .of .Exit .Discharge:
.that .story .that .is .either .(1) .the .lowest .from .which .not .less .than .50% .of .the