,Which answer is False? List three ways endoscopes can be used to meet patient needs.
A. Routine screening
B. Diagnostic treatment
C. Neuro screening
D. Therapeutic treatment - ANS B. Neuro Screening
True/False: Failure to provide a functional endoscope can result in an inaccurate diagnosis -
ANS True
A
Visual examination of the interior structures of the body is called :
A. Visioscopy
R
B. Endoscopy
C. Fiberoscopy
D. Robotoscopy - ANS B. Endoscopy
U
This scope examines the upper airway and nasal passages - ANS
This scope examines the lower gastrointestinal tract - ANS
Rhinolaryngoscope
Colonscope
LA
This scope examines the throat, trachea and lower airways - ANS Bronchoscope
This scope views the inside of the stomach(upper) - ANS Gastroscope
This scope type views the lower gastrointestinal tract (small bowel) - ANS Enteroscope
C
This scope examines the inside of the kidneys and urinary tract organs - ANS Cystoscope
This scope diagnoses and treats abnormalities of the Duodenum - ANS Duodenoscope
O
This scope is used to remove Gallstones - ANS Choledochoscope
D
This scope views the airways - ANS Flexible intubation scope
This scope visualizes the urinary tubes that connect the kidneys to the bladder - ANS
Ureteroscope
This scope examines the uterus - ANS Hysteroscope
The portion of the flexible endoscope that enters the body is called:
A. Control Body
B. Monitor cable
, C. Channel canal
D. Insertion tube - ANS D. Insertion tube
When using a flexible endoscope, instruments are introduced into the body through the:
A. Air port
B. Water port
C. Biopsy port
D. Injection port - ANS C. Biopsy port
Along with the benefits to the patient, endoscopic procedures benefit the facility by:
A. Reducing procedure time
A
B. Freeing up operating rooms
C. Reducing operation costs
D. Eliminating the need for surgery - ANS A. Reducing procedure time
R
Which of the following statements is true?
A. The average turnaround time for a flexible endoscope is 30 minutes
B. Flexible endoscopes should be replaced every two months
U
C. More healthcare-associated infections are linked to contaminated endoscopes than any other
device
D. One million endoscopies are performed each year - ANS C. More healthcare-associated
LA
infections are linked to contaminated endoscopes than any other device
A challenge to flexible endoscope reprocessing is:
A. Inadequate training
B. Complex design
C. Complex reprocessing instructions
C
D. All of the above - ANS D. All of the above
The insertion tube of a flexible endoscope can contain the :
A. Instrument channel
O
B. Control head
C. Scope body
D. Light guide connector - ANS A. Instrument channel
D
The most complex type of endoscope is the:
A. Semi-rigid endoscope
B. Hysteroscope
C. Laparoscope
D. Flexible endoscope - ANS D. Flexible endoscope
TRUE/FALSE: Operative (therapeutic) flexible endoscopes are used to identify possible disease
- ANS False