Which agency approves a site-specific variance which allows for an alternative method of construction or monitoring: a.) The Regional Water Quality Board b.) The State Water Resources Control Board c.) The Department of Toxic Substance Control d.) The local agency - ANS a.) The Regional Water Quality Board CCR Title 23, Sec 2681(a) The regulations to enforce compliance of underground storage tank systems in the state are found in? a.) Code of Federal Regulations, 40 CFR Part 281 b.) California Code of Regulations, Title 23, Chapter 16 c.) Code of Federal Regulations, 40 CFR Part 280 d.) California Code of Regulations, Title 23, Chapter 17 - ANS b.) California Code of Regulations; Title 23, Chapter 16 By definition an "underground storage tank system" includes a.) The tank, all connected piping and dispensers b.) The tank, all connected piping, ancillary equipment and containment system c.) Only the tank d.) Only tanks totally beneath the surface of the ground - ANS b.) The tank, all connected piping, ancillary equipment and containment system ICC CALIFORNIA UST INSPECTOR EXAM 2025 QUESTIONS AND ANSWERS @COPYRIGHT FYNDLAY 2025/2026 Page2 (H&SC, Sec 25281(z)) The written report submitted to the local agency after an unauthorized release is required to include the following except: a.) Description of actions taken to stop the release b.) Cause of the release c.) Method of disposal of released product d.) Date on which the release was discovered - ANS b.) Cause of the release CCR Title 23, Sec 2652(c) An unauthorized release which does not escape from secondary containment only requires a record on the operator's monitoring reports provided: A. It did not increase the hazard of fire B. It did not cause any deterioration of the secondary containment C. It was cleaned up within 8 hours of detection D. All of the above - ANS D. All of the above H&SC, Sec 25294 The annual monitoring certification may be performed by: A. A person possessing the appropriate contractors licenses B. An individual trained and certified by the manufacturer of the monitoring equipment C. A designated UST operator D. A person who meets the requirements of both a and b - ANS D. A person who meets the requirements of both a and b CCR Title 23, Sec 2715(i) When an automatic tank gauge is utilized for single-walled tank leak detection, it shall generate a post-test hard copy data report of the following information, except: a.) Liquid volume @COPYRIGHT FYNDLAY 2025/2026 Page3 b.) Fuel depth c.) Outside air temperature d.) Time and date of test - ANS c.) Outside air temperature CCR Title 23, Sec 2643(b)(1) If a UST system is utilizing an overfill alarm, the alarm must be triggered to alert the transfer operator when the tank is no more than ___________ full a.) 85% b.) 95% c.) 90% d.) 80% - ANS c.) 90% An automatic tank gauge is utilized for leak detection of the ______________. a.) Tank b.) Tank and Piping c.) Piping d.) Interstitial space - ANS a.) Tank CCR Title 23, Sec 2643(b)(1) After completion of enhanced leak detection (ELD) test, the ELD test results must be submitted to the _________________. a.) The local agency b.) The SWRCB c.) Owner of the UST system d.) To both the SWRCB and the local agency - ANS d.) To both the SWRCB and the local agency CCR Title 23, Sec 2644.1(a)(5) A permit to operate a

Meer zien Lees minder
Instelling
UST INSPECTOR
Vak
UST INSPECTOR

Voorbeeld van de inhoud

ICC CALIFORNIA UST INSPECTOR
EXAM 2025 QUESTIONS AND ANSWERS




Which agency approves a site-specific variance which allows for an alternative method of
construction or monitoring:
a.) The Regional Water Quality Board
b.) The State Water Resources Control Board
c.) The Department of Toxic Substance Control

d.) The local agency - ANS a.) The Regional Water Quality Board
CCR Title 23, Sec 2681(a)


The regulations to enforce compliance of underground storage tank systems in the state are
found in?
a.) Code of Federal Regulations, 40 CFR Part 281
b.) California Code of Regulations, Title 23, Chapter 16
c.) Code of Federal Regulations, 40 CFR Part 280

d.) California Code of Regulations, Title 23, Chapter 17 - ANS b.) California Code of
Regulations; Title 23, Chapter 16


By definition an "underground storage tank system" includes
a.) The tank, all connected piping and dispensers
b.) The tank, all connected piping, ancillary equipment and containment system
c.) Only the tank
1




d.) Only tanks totally beneath the surface of the ground - ANS b.) The tank, all connected
Page




piping, ancillary equipment and containment system
@COPYRIGHT FYNDLAY 2025/2026

, (H&SC, Sec 25281(z))


The written report submitted to the local agency after an unauthorized release is required to
include the following except:
a.) Description of actions taken to stop the release
b.) Cause of the release
c.) Method of disposal of released product

d.) Date on which the release was discovered - ANS b.) Cause of the release
CCR Title 23, Sec 2652(c)


An unauthorized release which does not escape from secondary containment only requires a
record on the operator's monitoring reports provided:
A. It did not increase the hazard of fire
B. It did not cause any deterioration of the secondary containment
C. It was cleaned up within 8 hours of detection

D. All of the above - ANS D. All of the above
H&SC, Sec 25294


The annual monitoring certification may be performed by:
A. A person possessing the appropriate contractors licenses
B. An individual trained and certified by the manufacturer of the monitoring equipment
C. A designated UST operator

D. A person who meets the requirements of both a and b - ANS D. A person who meets the
requirements of both a and b
CCR Title 23, Sec 2715(i)


When an automatic tank gauge is utilized for single-walled tank leak detection, it shall generate
2




a post-test hard copy data report of the following information, except:
Page




a.) Liquid volume
@COPYRIGHT FYNDLAY 2025/2026

, b.) Fuel depth
c.) Outside air temperature

d.) Time and date of test - ANS c.) Outside air temperature
CCR Title 23, Sec 2643(b)(1)


If a UST system is utilizing an overfill alarm, the alarm must be triggered to alert the transfer
operator when the tank is no more than ___________ full
a.) 85%
b.) 95%
c.) 90%

d.) 80% - ANS c.) 90%


An automatic tank gauge is utilized for leak detection of the ______________.
a.) Tank
b.) Tank and Piping
c.) Piping

d.) Interstitial space - ANS a.) Tank
CCR Title 23, Sec 2643(b)(1)


After completion of enhanced leak detection (ELD) test, the ELD test results must be submitted
to the _________________.
a.) The local agency
b.) The SWRCB
c.) Owner of the UST system

d.) To both the SWRCB and the local agency - ANS d.) To both the SWRCB and the local
agency
CCR Title 23, Sec 2644.1(a)(5)
3




A permit to operate a UST system must have all of the following listed on the permit, EXCEPT:
Page




@COPYRIGHT FYNDLAY 2025/2026

, a.) The state UST identification number(s)
b.) Name of the tank manufacturer and tank capacity
c.) Permit expiration date

d.) Monitoring requirements - ANS b.) Name of the tank manufacturer and tank capacity
CCR Title 23, Sec 2712(c)


A temporary closure is appropriate for which of the following:
a.) The UST system is empty and will be removed from service indefinitely
b.) The UST system has ceased to store hazardous materials but will be used within the next 12
consecutive months
c.) The UST system is unable to meet compliance requirements and will be removed

d.) The UST system has been red-tagged - ANS b.) The UST system has ceased to store
hazardous materials but will be used within the next 12 consecutive months
CCR Title 23, Sec 2671 & 2670


A local agency determines that a UST facility within the last year had compliance issues. Prior to
issuing a new permit or renewal to operate an UST the local agency shall:
a.) Ask the state to assist in a joint inspection
b.) Request the owner/operator to submit a "Return to Compliance" form.
c.) Refer to a District Attorney Investigator

d.) Inspect the facility and determine compliance - ANS d.) Inspect the facility and determine
compliance
CCR Title 23, Sec 2712(c)


All the following components require third party certification, except:
a.) Automatic tank gauging systems
b.) Statistical inventory reconciliation methods
c.) Spill Containment lids
4




d.) Liquid phase out-of-tank products - ANS c.) Spill Containment lids
Page




@COPYRIGHT FYNDLAY 2025/2026

Geschreven voor

Instelling
UST INSPECTOR
Vak
UST INSPECTOR

Documentinformatie

Geüpload op
12 augustus 2025
Aantal pagina's
135
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$13.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Fyndlay Kaplan University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
405
Lid sinds
2 jaar
Aantal volgers
81
Documenten
19899
Laatst verkocht
18 uur geleden
Scholar\'s Sanctuary.

Explore a Vast Collection of Finely Made Learning Materials.

3.7

72 beoordelingen

5
32
4
11
3
14
2
6
1
9

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen