Service |entrace |conductors |run |from |the |service |drop |to |the |service |box |or |service |panel. |True
|or |False? |- |CORRECT |ANSWER✔✔-True
The |service |size |is |determined |by |the |amperage |and |the |voltage |ratings |of |the |service. |- |
CORRECT |ANSWER✔✔-True
Is |the |service |drop |overhead |or |underground? |- |CORRECT |ANSWER✔✔-Overhead
Are |service |laterals |overhead |or |underground? |- |CORRECT |ANSWER✔✔-Underground
The |drip |loop |is |typically |part |of |the |service |drop. |True |or |False? |- |CORRECT |ANSWER✔✔-False
The |wire |size |for |the |service |drop |must |be |the |same |as |the |wire |size |for |the |service |entrance |
conductors. |True |or |False? |- |CORRECT |ANSWER✔✔-False
How |many |wires |would |you |typically |find |in |a |240-volt |service |drop? |- |CORRECT |ANSWER✔✔-
3
What |would |4 |wires |mean? |- |CORRECT |ANSWER✔✔-3-phase |electricity
What |would |2 |wires |usually |mean? |- |CORRECT |ANSWER✔✔-120 |volt |service
List |7 |common |problems |with |service |drops. |- |CORRECT |ANSWER✔✔-1. |Overhead |wires |too |
low.
,2. |Damaged |or |frayed |wires.
3. |Trees |or |vines |interfering |with |wires.
4. |Wires |too |close |to |doors |or |windows.
5. |Wires |not |well-secured |to |the |house.
6. |Poor |connection |between |service |drop |and |service |entrance.
7. |Inadequate |clearance |from |roofs.
List |clearances |above |ground, |swimming |pools, |and |roofs. |- |CORRECT |ANSWER✔✔-above |
roadway--18 |ft.
above |driveway--12 |ft.
above |flat |roof--8 |to |10 |ft.
above |sloped |roof--18 |inches
away |from |water |in |swimming |pool--22.5 |ft
3 |ft. |above |sloped |roof |with |pitch |> |4 |in |12
above |walkway--10 |ft.
The |service |entrance |conductors |run |from |the |_________ |to |the |___________. |- |CORRECT |
ANSWER✔✔-service |drop |to |service |box
All |service |entrance |conductors |must |be |in |conduit. |True |or |False? |- |CORRECT |ANSWER✔✔-
False
All |service |entrance |conductors |must |be |attached |above |roof |level. |True |or |False? |- |CORRECT |
ANSWER✔✔-False
The |drip |loop |should |be |as |close |to |the |roof |as |possible. |True |or |False? |- |CORRECT |
ANSWER✔✔-False
,List |10 |common |problems |with |service |entrance |conductors. |- |CORRECT |ANSWER✔✔-1. |No |
drip |loop
2. |No |mast |head
3. |Mast |head |not |weather |tight.
4. |Mast |or |conduit |bent.
5. |Mast |or |conduit |rusted.
6. |Mast |rotted |(if |wood).
7. |Mast |conduit |or |cable |not |well |secured.
8. |Mast |conduit |or |cable |not |weather |tight.
9. |Conduit |or |cable |not |well |sealed |at |house/wall |penetration.
10. |Cable |frayed, |damaged, |or |covered |by |siding.
List |4 |common |areas |of |water |penetration |into |service |entrances. |- |CORRECT |ANSWER✔✔-1. |
conduit |joints
2. |mast |head
3. |roof |flashing
4. |meter |base
5. |house |entry
List |2 |functions |of |the |drip |loop. |- |CORRECT |ANSWER✔✔-1. |Prevents |water |entry |into |the |
conduit |or |service |entrance |conductors.
2. |Shows |that |the |service |drop |wires |are |not |straining |the |splices.
Roughly |999 |out |of |1000 |houses |have |_________ |volts |available. |- |CORRECT |ANSWER✔✔-240
Roughly |999 |out |of |1000 |houses |have |__________ |service |entrance |wires. |- |CORRECT |
ANSWER✔✔-3
, Load |calculations |are |part |of |a |home |inspection. |- |CORRECT |ANSWER✔✔-False
Implications |of |an |undersized |service |include:
a. |shock |hazard
b. |fire |hazard
c. |shock |and |fire |hazard
d. |melting |insulation
e. |nuisance |tripping |of |the |main |fuses |and |breakers |- |CORRECT |ANSWER✔✔-e.
What |is |the |largest |single-phase |service |that |you |are |likely |to |find |in |a |home? |- |CORRECT |
ANSWER✔✔-400 |amps
What |size |copper |wire |would |you |expect |to |find |on |the |service |entrance |for:
a. |60-amp |service
b. |100-amp |service
c. |200-amp |service |- |CORRECT |ANSWER✔✔-a. |6 |gauge
b. |4 |gauge
c. |2-0 |gauge
Which |of |the |following |is |a |reliable |way |to |identify |the |service |size?
a. |the |size |of |the |service |drop |wires
b. |the |distribution |panel |rating
c. |the |service |box |rating
d. |the |service |entrance |conductor
e. |the |service |entrance |conduit |size |- |CORRECT |ANSWER✔✔-d.
With Correct Answers
Service |entrace |conductors |run |from |the |service |drop |to |the |service |box |or |service |panel. |True
|or |False? |- |CORRECT |ANSWER✔✔-True
The |service |size |is |determined |by |the |amperage |and |the |voltage |ratings |of |the |service. |- |
CORRECT |ANSWER✔✔-True
Is |the |service |drop |overhead |or |underground? |- |CORRECT |ANSWER✔✔-Overhead
Are |service |laterals |overhead |or |underground? |- |CORRECT |ANSWER✔✔-Underground
The |drip |loop |is |typically |part |of |the |service |drop. |True |or |False? |- |CORRECT |ANSWER✔✔-False
The |wire |size |for |the |service |drop |must |be |the |same |as |the |wire |size |for |the |service |entrance |
conductors. |True |or |False? |- |CORRECT |ANSWER✔✔-False
How |many |wires |would |you |typically |find |in |a |240-volt |service |drop? |- |CORRECT |ANSWER✔✔-
3
What |would |4 |wires |mean? |- |CORRECT |ANSWER✔✔-3-phase |electricity
What |would |2 |wires |usually |mean? |- |CORRECT |ANSWER✔✔-120 |volt |service
List |7 |common |problems |with |service |drops. |- |CORRECT |ANSWER✔✔-1. |Overhead |wires |too |
low.
,2. |Damaged |or |frayed |wires.
3. |Trees |or |vines |interfering |with |wires.
4. |Wires |too |close |to |doors |or |windows.
5. |Wires |not |well-secured |to |the |house.
6. |Poor |connection |between |service |drop |and |service |entrance.
7. |Inadequate |clearance |from |roofs.
List |clearances |above |ground, |swimming |pools, |and |roofs. |- |CORRECT |ANSWER✔✔-above |
roadway--18 |ft.
above |driveway--12 |ft.
above |flat |roof--8 |to |10 |ft.
above |sloped |roof--18 |inches
away |from |water |in |swimming |pool--22.5 |ft
3 |ft. |above |sloped |roof |with |pitch |> |4 |in |12
above |walkway--10 |ft.
The |service |entrance |conductors |run |from |the |_________ |to |the |___________. |- |CORRECT |
ANSWER✔✔-service |drop |to |service |box
All |service |entrance |conductors |must |be |in |conduit. |True |or |False? |- |CORRECT |ANSWER✔✔-
False
All |service |entrance |conductors |must |be |attached |above |roof |level. |True |or |False? |- |CORRECT |
ANSWER✔✔-False
The |drip |loop |should |be |as |close |to |the |roof |as |possible. |True |or |False? |- |CORRECT |
ANSWER✔✔-False
,List |10 |common |problems |with |service |entrance |conductors. |- |CORRECT |ANSWER✔✔-1. |No |
drip |loop
2. |No |mast |head
3. |Mast |head |not |weather |tight.
4. |Mast |or |conduit |bent.
5. |Mast |or |conduit |rusted.
6. |Mast |rotted |(if |wood).
7. |Mast |conduit |or |cable |not |well |secured.
8. |Mast |conduit |or |cable |not |weather |tight.
9. |Conduit |or |cable |not |well |sealed |at |house/wall |penetration.
10. |Cable |frayed, |damaged, |or |covered |by |siding.
List |4 |common |areas |of |water |penetration |into |service |entrances. |- |CORRECT |ANSWER✔✔-1. |
conduit |joints
2. |mast |head
3. |roof |flashing
4. |meter |base
5. |house |entry
List |2 |functions |of |the |drip |loop. |- |CORRECT |ANSWER✔✔-1. |Prevents |water |entry |into |the |
conduit |or |service |entrance |conductors.
2. |Shows |that |the |service |drop |wires |are |not |straining |the |splices.
Roughly |999 |out |of |1000 |houses |have |_________ |volts |available. |- |CORRECT |ANSWER✔✔-240
Roughly |999 |out |of |1000 |houses |have |__________ |service |entrance |wires. |- |CORRECT |
ANSWER✔✔-3
, Load |calculations |are |part |of |a |home |inspection. |- |CORRECT |ANSWER✔✔-False
Implications |of |an |undersized |service |include:
a. |shock |hazard
b. |fire |hazard
c. |shock |and |fire |hazard
d. |melting |insulation
e. |nuisance |tripping |of |the |main |fuses |and |breakers |- |CORRECT |ANSWER✔✔-e.
What |is |the |largest |single-phase |service |that |you |are |likely |to |find |in |a |home? |- |CORRECT |
ANSWER✔✔-400 |amps
What |size |copper |wire |would |you |expect |to |find |on |the |service |entrance |for:
a. |60-amp |service
b. |100-amp |service
c. |200-amp |service |- |CORRECT |ANSWER✔✔-a. |6 |gauge
b. |4 |gauge
c. |2-0 |gauge
Which |of |the |following |is |a |reliable |way |to |identify |the |service |size?
a. |the |size |of |the |service |drop |wires
b. |the |distribution |panel |rating
c. |the |service |box |rating
d. |the |service |entrance |conductor
e. |the |service |entrance |conduit |size |- |CORRECT |ANSWER✔✔-d.