NFPA 54 Exam Questions and Answers
2025/2026 A+ Graded 100% Verified
NFPA 54 - ANS -National fuel gas code

Color use to identify natural - ANS -yellow

Specific gravity of gas - ANS -0.60 lighter then air

Elevated pressure of gas into a building - ANS -1/2 or 14 water column or greater

Ways to join gas pipe together - ANS -Weld, Threaded, Flared, Cast

Minimum gas piping size concealed - ANS -1/2

Minimum gas size buried - ANS -3/4

Gas pressure test for new pipe - ANS -3psi for 10 min

Gas pressure test for existing pipe - ANS -1 1/2 psi for 10 min

Never test Gas pipe - ANS -oxygen

test gauges calibrated - ANS -1/2 pound increments maximum 5 psi

Depth of a trench for gas - ANS -12 inch depth min, if hazards are found, 18 inches max

1 inch of mercury= - ANS -1/2 pound=

Components of natural gas - ANS -Methan 90%, Propane 5%, ethan 5%

Btu or British Thermal Unit - ANS -Amount of heat required to raise the temp of 1 pound
of water one degree Fahrenheit.

Ratio of air to natural gas for combustion - ANS -10 parts air to 1 part natural gas

In one cubic foot of gas there is - ANS -1,000 Btu's

Wire used under ground for gas - ANS -14 gauge tracer wire

, Distance between gas regulator and point of ignition - ANS -3 ft min

Pitch of gas pipe - ANS -1/4 per 15 ft

Plastic pipe for gas can only be used - ANS -Outside under ground and cannot penetrate
foundation or go under foundation.

Drip T's in gas lines must be placed - ANS -First change of direction after meter and at
any change of direction from horizontal to vertical.

Penetration of gas pipe through floors, patio or slab - ANS -No less then 2 inch of
unthreaded pipe.

All drip Tee's must have at least - ANS -3" between cap and tee.

Changing a chimerical gas stove with an exhaust hood is what must be done. - ANS -A
solenoid valve must be installed and wired to exhaust. If other units are present,
solenoids must be placed upstream of all fixtures.

Gas equipment shall not utilize any combustion air or ventilation air from - ANS
-Bedroom or bath room

Type 1 clothes dryers can be installed in closets in bed rooms or baths only when - ANS
-Combustion and ventilation air is introduced to the space with an air intake equal to or
greater then the size of the exhaust. The combustion and ventilation air must come from
a space that is sized correctly for combustion.

Gas flex hoses installled in industrial appliance - ANS -Shall not exceed 6ft

Direct gas fired Industrial Air Heaters may not be utilized unless manufacturer states that
there is no more then - ANS -50 ppm of carbon monoxide in total volume discharged
from unit

Room heaters shall not be installed - ANS -bathrooms or bed rooms unless they are
direct vented

unvented room heaters permits can not be given until - ANS -A permit is obtained from
fire department

Gas piping systems in excess of one million btu input shall be tested for a maximum of -
ANS -Not more than 24 hours

AWS - ANS -American Welding Society

Geschreven voor

Instelling
NFPA 54
Vak
NFPA 54

Documentinformatie

Geüpload op
29 augustus 2025
Aantal pagina's
8
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$16.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
AVERYSELLER Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
278
Lid sinds
3 jaar
Aantal volgers
121
Documenten
3133
Laatst verkocht
1 week geleden

3.8

44 beoordelingen

5
19
4
7
3
10
2
4
1
4

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen