This is the actual weight pressing down on the fifth wheel hitch by the pin box of the fifth
wheel trailer - Answer-Pin weight
This is the maximum operating weight of a vehicle as specified by the manufacturer -
Answer-GVWR (gross vehicle weight)
This is the weight of a fully loaded vehicle and must not exceed the GVWR - Answer-
GVW gross vehicle weight
Weight of the vehicle as configured for delivery - Answer-UVW unloaded vehicle weight
This is the maximum allowable total loaded weight rating of a vehicle and trailer/towable
- Answer-GCWR gross combination weight rating
This test is used to determine what pressure the system regulator is delivering at least
50% of appliance load is functioning - Answer-Operating pressure test
This test is used to locate a leak in the propane system - Answer-Bubble solution test
During operating pressure test manometer should read about __ in Wc - Answer-11
This test is used to verify pressure at which the regulator locks up when no propane is
flowing - Answer-Lock up pressure test
During lock up pressure test reading must never exceed ___ in Wc - Answer-14
This test is used to determine if the propane system is leak free by dropping internal
pressure to 8 in Wc for 3 minutes - Answer-Timed pressure drop test
During a Pdi on the propane system technician should set delivery line pressure, verify
regulator lock up pressure, preform a ________ _________ _________, check
connections using a bubble solution - Answer-Times pressure drop test
Rv water distribution system needs what 2 things to function? - Answer-A source or
potable water and a means to provide pressure
4 Methods of obtaining pressure for water system - Answer-1. City water pressure
2. Demand pump
, 3. Manual pump system
4. Air pressurized
The water __________ system consists of piping, freshwater, storage tank, water
heater, water pump and faucets - Answer-Distribution
What is the purpose of the bypass valve on a water heater - Answer-Used during
winterization to keep antifreeze out of water heater
Accumulator: - Answer-Installed downstream of pump to assist with consistent water
pressure
Water regulator - Answer-Reduces water pressure (as high as 150psi) down to about
40-50psi
Water filters - Answer-Filter out impurities
The the water distribution system the High pressure check valve is located in 2 places
and does? - Answer-Located at the pump outlet to protect from city water pressure and
the water heater inlet to prevent back flow of water.
These gauges are used to test water systems for leaks - Answer-Pressure gauge
In-line strainer: (water system) - Answer-Located between tank and pump to catch dirt
and debris
This test is used to test for leaks in the water distribution system - Answer-Pressure test
How do you preform a water pressure test - Answer-Use 80-100 psi air pressure for a
minimum of 10 minutes, should have no drop in pressure if leak free
This test is done by subjecting the water system to the maximum discharge pressure
listed on the pump for 10 mins (looking for leaks) - Answer-Demand system test
There are __ grades of antifreeze used for winterization - Answer-2
Traps are installed at every fixture in the water drainage system to? - Answer-Prevent
gases and odors from entering Rv
Propane system functions at ___ in Wc - Answer-11
The maximum lock up pressure for propane regulator is ___ in Wc - Answer-14
The 1st stage regulator reduces propane container pressure to about ___ psi - Answer-
10