187 minutes of flight time would be labeled as how many hours in ALMIS? - ANSWER: 3.1
3 types of structure area's are _________? - ANSWER: AIRCRAFT SKIN AREAS ARE CLASSIFIED AS
FOLLOWS: HIGHLY CRITICAL (MUST PROVIDE 100 PERCENT STRENGTH REPLACEMENT) SEMI-
CRITICAL (REQUIRES 80 PERCENT STRENGTH REPLACEMENT) NON-CRITICAL (REQUIRES 60
PERCENT STRENGTH REPLACEMENT) AMT1 6.B.14
4 ways hydraulic cleaning and filtering? - ANSWER: FLUSHING, PURGING, PURIFYING, AND
RECIRCULATION IAW NAV AIR 01-1A-17 PAGE5-1
A 5 degree temprature change equals to what % tire pressure change - ANSWER: 1%
A 5 degree temprature change equals to what % tire pressure change - ANSWER: 1%
A bolt part number ending in the letter A means what? - ANSWER: No holes in head for safety wire
A bolt part number ending in the letter A means what? - ANSWER: No holes in head for safety wire
A cam on a nose is for what? - ANSWER: NOSE GEAR SHOCK STRUTS ARE THE SAME IN DESIGN
BUT ARE PROVIDED WITH A CENTERING DEVICE. THE CENTERING DEVICE CONSISTS OF AN
UPPER LOCATING CAM ATTACHED TO THE UPPER CYLINDER AND A MATING LOWER
LOCATING CAM ATTACHED TO THE LOWER CYLINDER. WHEN THE GEAR IS IN THE FULLY
EXTENDED POSITION, THE CAMS WILL LINE UP THE WHEEL AND AXLE ASSEMBLY IN THE
STRAIGHT-AHEAD POSITION. THIS PREVENTS THE NOSE WHEEL FROM BEING COCKED TO
ONE SIDE WHEN THE NOSE GEAR IS RETRACTED. THE MATING CAMS ALSO KEEP THE NOSE
WHEEL IN A STRAIGHT AHEAD POSITION PRIOR TO LANDING WHEN THE STRUT IS FULLY
EXTENDED. IAW AMT2 SYSTEM PQG PAGE 5-5
A class 1 fuel cell permit allows what inside a fuel cell? - ANSWER: Emergency Entry Only
A fuel leak consisting of 4 drops per minute on an external fuel tank is classified as a? - ANSWER: Class C
Heavy Seep NAVAIR 1-1A35
,A fuel leak that is 4 drops per hours is defined as what type of leak? - ANSWER: Class C
A HALON FIRE EXTINGUSHER HAS WHAT COLOR BAND AROUND IT - ANSWER: SILVER
A helicopter hoist cable has a trail line length of how long? - ANSWER: 110 feet
A helicopter tail rotor offsets what force? - ANSWER: Translating Tendency
A near miss with no injury or aircraft damage is considered what class mishap? - ANSWER: Class D Aviation
Mishap CIM-5100.47 pg3-7
A pressurized hydraulic system prevents what? - ANSWER: STALLING
A properly serviced ECS system with Freon, what will the sight glass indicate? - ANSWER: DURING
REFRIGERATION UNIT OPERATION, A STEADY FLOW OF FREON REFRIGERANT OBSERVED
THROUGH THE SIGHT GLASS INDICATES THAT SUFFICIENT CHARGE IS PRESENT. IF THE UNIT
REQUIRES ADDITIONAL REFRIGERANT, BUBBLES WILL' BE PRESENT IN THE SIGHT GLASS.
A salvage report shall be submitted to CG-41 within how many days? - ANSWER: 30 days
A Teflon back up ring is required when pressure is over 1500 psi? Why? - ANSWER: MOST MODERN
HYDRAULIC SYSTEMS USE O-RINGS FOR BOTH PACKINGS AND GASKETS. O-RINGS FIT INTO
GROOVES IN ONE OF THE SURFACES BEING SEALED. AN O-RING OF THE APPROPRIATE SIZE
CAN WITHSTAND PRESSURES UP TO ABOUT 1500 PSI WITHOUT DISTORTION, BUT BEYOND
THIS, THERE IS A TENDENCY FOR THE RING TO EXTRUDE INTO THE GROOVE BETWEEN THE
TWO MATING SURFACES. TO PREVENT THIS, A TEFLON ™ BACKUP RING IS USED. IAW AMT2
SYSTEM PQG PAGE 3-10
A tire has markings 46x17R20. What does the R stand for? - ANSWER: Radial
A tire marked 20x6.6-10. What is the tire cross section width? - ANSWER: 6.6 inches
A&P Manual Airframe V2 pg. 13-77
Above ground dirty oil containers should be able to hold how much? - ANSWER:
,After a mishap requiring a Mishap Board, members must do a pre-mishap screening of how many hours? -
ANSWER: 72 hour pre mishap history worksheet 5100.47 pg3-41
After a mishap, a member must be screened within how many hours? - ANSWER: 2 hours CIM 5100.47 pg3-40
After a mishap, what is the most days of missed work by an employee for it to be labeled a Class C? -
ANSWER:
After chemical conversion coating, who long must you wait to apply paints or sealants? - ANSWER: A
minimum of 1 hour but not more than 72 hours
After chemical conversion coating, who long must you wait to apply paints or sealants? - ANSWER: A
minimum of 1 hour but not more than 72 hours
After how long do you need a warm-up flight? - ANSWER: AN AIRCREW MEMBER THAT HAS NOT
FLOWN IN HIS OR HER PRIMARY AIRCREW DESIGNATION (IN-FLIGHT OR IN AN APPROVED
SIMULATOR) DURING THE PREVIOUS 30 DAYS IS REQUIRED TO FLY A WARM-UP TRAINING
FLIGHT IN THEIR PRIMARY AIRCREW DESIGNATION PRIOR TO FLYING IN THAT CREW
POSITION ON AN OPERATIONAL MISSION. IAW 3710.1F PAGE 8-40
After how many hours of signal outage, should paper log books be used? - ANSWER: 4 hours PG-110 pg5-9
AFTO Form 103 shall be completed IAW what reference? - ANSWER: AFTO 00-25-4
Aircraft washrack water should be between what temperature range? - ANSWER: 120-140
Aircraft Weight and Balance Process Guide - ANSWER: PG-85-00-180-A
ALC and Prime Unit flights - ANSWER:
Aluminum alloys develop a thin layer of oxidation between ______________ that is not considered detrimental.
- ANSWER:
, An APU has how many major sections? - ANSWER: 3
An E-5 with more than 6 years in Aviation makes how much flight pay? - ANSWER: $190 CIM-7220.29 p5-23
Approximately how much power is transferred to the propellers in a turboprop engine? - ANSWER: Between
50 and 87%
A&P Manual Powerplant V2
At what decibel is it required to use double hearing protection? - ANSWER: 104 Db
At what decibel is it required to use double hearing protection? - ANSWER: 104 Db
At what humidity level will the color coded indicator turn pink in a preserved engine? - ANSWER: 40%
At what humidity level will the color coded indicator turn pink in a preserved engine? - ANSWER: 40%
at which light did Ida Lewis work? - ANSWER: Lime Rock
at which light did Ida Lewis work? - ANSWER: Lime Rock
ATF3 lead generator T3 is connected to what/where? - ANSWER: X5017A6B HU25 MPC 242020.0 PG 3
Before engine starts, who ensures the engines are clear? - ANSWER: Fire guard
Before engine starts, who ensures the engines are clear? - ANSWER: Fire guard
Before you hook up a hydraulic generator what must you check for? - ANSWER: LOW AMBIENT
TEMPERATURE AND HIGH RELATIVE HUMIDITY MAY CAUSE ICE IN PNEUMATIC SYSTEM AND
RENDER AIR DRIVEN PUMP INOPERATIVE IAW 17-15BF-90