____ occur when some portion of a UST system fails and allows fuel to escape into the
surrounding soil or groundwater or the pavement surrounding the fuel islands. - ANS -
Releases
______ line leak detectors can detect leaks of 3.0 gph. - ANS - not all or none of
these wtf
______ sensors can distinguish between different types of liquid in the interstitial space.
- ANS - discriminating
A Class C operator must be on-site at a staffed facility during all hours of operation. -
ANS - true
A red tag affixed to a USTs fill pipe means that ______. - ANS - The UST or UST
system is ineligible for delivery, deposit, or acceptance of product
A spill or overfill of petroleum product in excess of ___ gallons must be reported to the
DEQ within 24 hours of discovery. - ANS - 25
All new dispensers must have _____. - ANS - UDC
All performance claims pertaining to any release detection system and the manner in
which these claims have been justified or tested by the equipment manufacturer or
installer must be maintained for_______. - ANS - Five years
An owner/operator is not required to maintain financial responsibility after selling a UST
facility. - ANS - false
An owner/operator may use which of the following mechanisms to meet financial
responsibility requirements? - ANS - Any of the above
An owner/operator must leave vent lines open and functioning if a UST remains in
temporary closure for ___ months or more. - ANS - 3
, An owner/operator must submit a completed Notification for Underground Storage
Tanks form to the DEQ regional office within _____ days of bringing a UST into use. -
ANS - 30
An owner/operator must submit financial responsibility documentation to the state UST
program within ___ days of discovering a reportable release. - ANS - 30
As of 1998, ______ USTs were required to have some form of corrosion protection. -
ANS - steel
At least ___ prior to permanently closing a UST, the owner/operator must submit written
notification of the intent to close the UST to the DEQ. - ANS - not 90
At least ______ prior to closing the UST, the owner/operator must notify the DEQ of the
intent to close the UST. - ANS - 30 days
ATG equipment that tests for loss of product and conducts inventory control must be
able to detect a leak rate of ___________. - ANS - 0.2
Automatic line leak detectors must be tested at least ______. - ANS - no daily or
month
Ball float valves should be able to restrict vapor flow when the tank reaches ___ of its
capacity. - ANS - 90%
Cathodic testing by a trained cathodic specialist must be conducted every ____. - ANS
- Three years
Class A and Class B operators must be trained within ___ days after assuming
operation and maintenance duties at the UST facility. - ANS - 30
Class C operator training must include information on ___________. - ANS - All of
these examples
Class C operators must be trained before assuming responsibility for responding to
emergencies at the UST facility. - ANS - true
Class C operators should be trained to activate the E-Stop instead of the All Stop in
case of an emergency. - ANS - true