lass B Operator's primary responsibilities include:
Release detection, spill and overfill prevention are in place and functioning, testing
records are retained and available, and Class C Operators are trained and onsite during
facility operations
A Class B Operator
Statutory and regulatory; day to day operations and records
An unattended facility must have all of the following EXCEPT:
Posted directions to the nearest hospital that has an emergency room
Owners must designate a Class A, B and C Operator for ______.
each UST system
Cadolic protection is not required for which of the following double-walled underground
tanks?
Fiberglass tanks
Installers of new tanks and piping must certify that
The installation was completed according to state regulations
Some components of a storage tank system may include the following:
Vent and vapor lines, release detection equipment such as automatic tank gauges (or
ATG's), a service station building.
Which of the following inspection methods is not an approved method to certify proper
installation of a tank system
Inspection by the Owner or Operator
,Regulated substances are often referred to as?
Product
A double-walled tank contains both of these:
An inner and outer wall
If a sump is not installed around the STP, then in order to prevent the components from
corroding, you must do the following EXCEPT:
Dig out the soil from around the sump and ensure that water is not coming in contact
with the components
The primary components of a storage tank are:
The tanks and connected piping
The inner and outer walls of double-walled fiberglass tank must be constructed of:
Fiberglass
According to the definition of an AST, what percent of the tank and associated piping
must be above the ground surface in order for a tank to be considered an AST?
90%
The simplest type of UST is a
Single-walled UST
In order to install, repair or modify a storage tank system, the owner or operator must
use
A person certified by the department to conduct these activities
What are the three different types of piping that can be associated with a storage tank?
Suction, pressurized, and atmospheric
, According to the definition of an UST, what percent of the tank and associated piping
must be below the ground in order for a tank to be considered an UST?
10%
A storage tank system includes both underground and above ground components used
to ______ product such as gasoline or diesel
Store and dispense
Heating oil is considered a regulated substance because it is made from?
Oil
A secondary component of a storage tank system is a
Sump
What would happen if a leak occurred and the STP did not have a sump
Contamination of the soil around the STP would occur
As of July 1, 2011 any UST being used as an AST must be
Closed
Some components of a storage tank system may include the following:
Storage tanks and piping, spill buckets and sumps, dispensers (or MPDs)
An AST with a capacity greater than _______ is not regulated by New Mexico PSTB
55,000
The shear valve is located _____.
On the product piping entering the bottom of the dispenser