Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

JOURNEYMAN AND MASTER PLUMBING EXAM WITH QUESTIONS AND VERIFIED ANSWERS|| GUARANTEED PASS || ALREADY GRADED A+ || LATEST VERSION 2025

Rating
-
Sold
-
Pages
25
Grade
A+
Uploaded on
11-09-2025
Written in
2025/2026

JOURNEYMAN AND MASTER PLUMBING EXAM WITH QUESTIONS AND VERIFIED ANSWERS|| GUARANTEED PASS || ALREADY GRADED A+ || LATEST VERSION 2025 What minimum size pipe is required for a vertical wet vent? - ANSWER-2 inches What is the minimum slope for a vent for an island sink? - ANSWER-1/4 A combination waste and vent drain requires a vent. The vent pipe is required to be what minimum percent of the cross-sectional area of therein pipe served? - ANSWER-50% In a combination waste and vent system, a fixture with a 2 inch tail piece must use a trap at least _____________ in size - ANSWER-four inches The gauge of drawn brass "p" traps that may be used on fixtures discharging domestic sewage but excluding urinals - ANSWER-17 gauge Brass tubing traps shall be - ANSWER-exposed and readily accessible On an emergency floor drain, which of the following is to be installed? - ANSWER-Backwater valve A grease interceptor installed in a commercial building is allowed to receive the waste from all of the following except a - ANSWER-food waste grinder What maximum length is allowed for a 2" trap arm? - ANSWER-5 feet 0 inches The developed length between the trap of a water closet and its vent shall not exceed - ANSWER-6 feet What is a corrugated line connecting a gas valve to an appliance called? - ANSWER-An appliance connector What minimum amount of time is required to test a low pressure gas piping system? - ANSWER-10 minutes Cleanout may be omitted on a horizontal drain line less than _____________ feet in length unless such line is serving sinks or urinals. - ANSWER-5 Excepting the building drain and its horizontal branches, a cleanout shall not be required on any pipe which is above the _____________________ of a building. - ANSWER-first floor An additional cleanout shall be provided in a horizontal drainage line for each aggregate change of direction exceeding ___________________ degrees. - ANSWER-135 Cleanout for 2" pipe and smaller shall have a minimum clearance of _____________________ inches. - ANSWER-12 What minimum amount of clearance is required in front of a 4" cleanout? - ANSWER-18 inches Refer to the table at the end of this exam. What is the maximum number of fixture units allowed for a 4" building drain that has 1/8" per foot slope? - ANSWER-172.8 fixture units The required size cleanout plug for a 4 inch and larger pipe is - ANSWER-3.5 inches Refer to the table at the end of this exam. An 8" building sewer with an 1/8" per foot grade is approved for what maximum drainage fixture unit load? - ANSWER-2800 fixture units What is the minimum gallon per minute for a sewer ejector? - ANSWER-20 gallons per minute

Show more Read less
Institution
JOURNEYMAN AND MASTER PLUMBING
Course
JOURNEYMAN AND MASTER PLUMBING

Content preview

JOURNEYMAN AND MASTER PLUMBING
EXAM WITH QUESTIONS AND VERIFIED
ANSWERS|| GUARANTEED PASS || ALREADY
GRADED A+ || LATEST VERSION 2025




What minimum size pipe is required for a vertical wet vent? - ANSWER-2
inches


What is the minimum slope for a vent for an island sink? - ANSWER-1/4


A combination waste and vent drain requires a vent. The vent pipe is required to
be what minimum percent of the cross-sectional area of therein pipe served? -
ANSWER-50%


In a combination waste and vent system, a fixture with a 2 inch tail piece must
use a trap at least _____________ in size - ANSWER-four inches


The gauge of drawn brass "p" traps that may be used on fixtures discharging
domestic sewage but excluding urinals - ANSWER-17 gauge


Brass tubing traps shall be - ANSWER-exposed and readily accessible


On an emergency floor drain, which of the following is to be installed? -
ANSWER-Backwater valve


A grease interceptor installed in a commercial building is allowed to receive the
waste from all of the following except a - ANSWER-food waste grinder

,What maximum length is allowed for a 2" trap arm? - ANSWER-5 feet 0 inches


The developed length between the trap of a water closet and its vent shall not
exceed - ANSWER-6 feet


What is a corrugated line connecting a gas valve to an appliance called? -
ANSWER-An appliance connector


What minimum amount of time is required to test a low pressure gas piping
system? - ANSWER-10 minutes


Cleanout may be omitted on a horizontal drain line less than _____________
feet in length unless such line is serving sinks or urinals. - ANSWER-5


Excepting the building drain and its horizontal branches, a cleanout shall not be
required on any pipe which is above the _____________________ of a
building. - ANSWER-first floor


An additional cleanout shall be provided in a horizontal drainage line for each
aggregate change of direction exceeding ___________________ degrees. -
ANSWER-135


Cleanout for 2" pipe and smaller shall have a minimum clearance of
_____________________ inches. - ANSWER-12


What minimum amount of clearance is required in front of a 4" cleanout? -
ANSWER-18 inches

, Refer to the table at the end of this exam. What is the maximum number of
fixture units allowed for a 4" building drain that has 1/8" per foot slope? -
ANSWER-172.8 fixture units


The required size cleanout plug for a 4 inch and larger pipe is - ANSWER-3.5
inches


Refer to the table at the end of this exam. An 8" building sewer with an 1/8" per
foot grade is approved for what maximum drainage fixture unit load? -
ANSWER-2800 fixture units


What is the minimum gallon per minute for a sewer ejector? - ANSWER-20
gallons per minute


The minimum distance from center to center to any similar fixture for water
closets or bidets shall be _______________________ inches. - ANSWER-30


The clear space in front of any water closet shall be not less than - ANSWER-
24 inches


Urinals shall not be set closer than 12 inches from their center to any side wall
or partition nor closer than _______________ inches center to center. -
ANSWER-24


Water closets installed for public use must - ANSWER-be elongated


A test for shower receptors shall be accomplished by - ANSWER-filling to the
level of the rough threshold


Shower pans shall be tested for water tightness by filling with water to not less
than the - ANSWER-top of the rough threshold

Written for

Institution
JOURNEYMAN AND MASTER PLUMBING
Course
JOURNEYMAN AND MASTER PLUMBING

Document information

Uploaded on
September 11, 2025
Number of pages
25
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$18.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
martinmwambingu54 Johns Hopkins University
Follow You need to be logged in order to follow users or courses
Sold
12
Member since
11 months
Number of followers
1
Documents
1243
Last sold
2 weeks ago
A+ EXAM ARCHIVES YOUR BLUEPRINT FOR ACADEMIC SUCCESS!

Welcome to A+ EXAM ARCHIVES – Your New Frontier for Academic Success on Stuvia! We\'re pioneering a fresh approach to study resources. We\'re dedicated to bringing you meticulously engineered, verified study solutions designed to unlock your full potential and drive remarkable academic success. Our commitment is clear: to provide cutting-edge content that is not only exceptionally clear and accurate but also strategically optimized to streamline your learning process. Whether you\'re aiming to master complex concepts, prepare for upcoming challenges, or simply seeking intelligent, reliable study tools, our curated collection of next-gen notes, agile summaries, and comprehensive learning frameworks is built to give you a distinct advantage. We understand that today\'s students need more than just information – they need effective, innovative solutions. That\'s why every document we create is thoughtfully developed to meet your specific learning requirements, ensuring you have the powerful tools to navigate your academic journey with absolute confidence. Join us at the forefront of smarter studying. Explore our store today and be among the first to experience a new level of academic support. Activate your A+ potential now!

Read more Read less
4.0

2 reviews

5
0
4
2
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions