Direct connection of two or more compatible control units is sometimes referred to as ?
communication.
Select one:
a.Class A
b.home-to-base
c.peer-to-peer
d.straight in
c.peer-to-peer
A technology that allows fire alarm signals to be sent over a local area network is called ? .
Select one:
a.BACNet
b.BAKNet
c.BASNet
d.BAXNet
a.BACNet
Which of the following building systems are sometimes integrated with fire alarm systems?I.
ElevatorsII. HVACIII. Door unlocking
Select one:
a.I. and II.
b.I. and III.
c.II. and III.
d.I., II., and III.
d.I., II., and III.
1|Page
,Which of the following types of suppression systems are usually supervised by a fire alarm
system?I. Automatic fire sprinkler systems (wet/dry)II. Dry chemical suppression systemsIII. Fire
pumpsIV. Kitchen hoodsV. Preaction suppression systems
Select one:
a.I., II., III., IV., and V.
b.I. and III.
c.III. and IV.
d.III., IV., and V.
a.I., II., III., IV., and V.
Suppression system controls must be provided with ? to prevent inadvertent tripping during fire
alarm testing.
Select one:
a.a password
b.a physical switch
c.software
d.terminals where conductors can be lifted
b.a physical switch
Electric fire pumps must be supervised for ? .
Select one:
a.loss of phase
b.phase reversal
c.pump running
d.all of the above
d.all of the above
Diesel fire pumps must be supervised for ? .
Select one:
a.controller off
b.controller or engine trouble
c.engine running
d.all of the above
d.all of the above
Which of the following statements is TRUE?
Select one:
a.Each individual supervisory signal must be transmitted from the suppression controls to the
2|Page
, main fire alarm controls.
b.Only a common supervisory signal is required to be transmitted from the suppression controls
to the main fire alarm controls.
c.Only supervisory signals must be transmitted from the suppression controls to the main fire
alarm controls.
d.Only trouble signals must be transmitted from the suppression controls to the main fire alarm
controls.
b.Only a common supervisory signal is required to be transmitted from the suppression controls
to the main fire alarm controls.
What minimum number of fire alarm control circuits (for Phase I recall) is required for each
group of elevators?
Select one:
a.1
b.2
c.3
d.4
c.3
The ? is selected by the authority having jurisdiction (AHJ).
Select one:
a.designated elevator recall level
b.elevator lobby detector coverage
c.hoistway pit detector location
d.number of elevator control circuits
a.designated elevator recall level
Where the elevator hoistway and machine room are sprinklered, heat detectors with a ?
temperature rating and a ? sensitivity than the sprinklers in the area are required.
Select one:
a.higher / higher
b.higher / lower
c.lower / higher
d.lower / lower
c.lower / higher
Heat detectors used for shunt trip are not required to be connected to the fire alarm system and
are not required to be monitored for integrity.
3|Page