Permits presuming to give authority to cancel the
requirements of the IRC code or other ordinances of the
jurisdiction shall __________ - Answer-not be valid
Given: The building official can issue a permit for any part
of a building or structure before the construction
documents for the whole building or structure have been
submitted, provided that adequate information and
detailed statements have been filed complying with
pertinent requirements of this code. This is known as a
_____________ approval. - Answer-phased
Given: A 240 volt branch circuit rated at 30 amperes is
installed for a cord and plug-connected appliance and
shall not exceed 80 percent of the branch circuit ampere
rating. What is the maximum load permitted for the
appliance? - Answer-5760 VA
, 2|Page
Panel-boards and over-current protection devices shall not
be located in _________ - Answer-clothes closets
Which conductor in a multi-wire branch circuit shall not be
dependent on connection to devices such as receptacles
for continuity? - Answer-Grounded conductor
What is the minimum size circuit conductor permitted to be
connected in parallel? - Answer-1/0 AWG
What is the minimum clearance required for overhead
open conductors located near sides and bottoms of
windows? - Answer-3 feet
_________________ of service equipment is required to
identify it as being suitable for use as service equipment. -
Answer-Marking
Underground service conductors not encased in concrete
and required to be buried 18 inches below grade shall
have their location identified by a _______________ at
least 12 inches above the conductors within the trench. -
Answer-warning ribbon