Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

Fire Alarm Level II Actual Exam Preparation Newest 2025/ 2026 Complete 100 Questions And Correct Answers With Rationales (Verified Answers)|Already Graded A+||Latest Exam!!||

Beoordeling
-
Verkocht
-
Pagina's
33
Cijfer
A+
Geüpload op
17-09-2025
Geschreven in
2025/2026

Fire Alarm Level II Actual Exam Preparation Newest 2025/ 2026 Complete 100 Questions And Correct Answers With Rationales (Verified Answers)|Already Graded A+||Latest Exam!!||

Instelling
Fire Alarm Level II
Vak
Fire Alarm Level II

Voorbeeld van de inhoud

1|Page


Fire Alarm Level II Actual Exam Preparation Newest
2025/ 2026 Complete 100 Questions And Correct
Answers With Rationales (Verified Answers)|Already
Graded A+||Latest Exam!!||


According to the IBC, which of the following fire alarm
systems are required in a group F occupancy. - Answer-A
manual fire alarm system with occupant notification


IBC, Fire alarm and smoke detection systems, factory


According to the IBC, shop drawings shall include -
Answer-A floor plan that indicates the use of all rooms,
annunciator, and voltage drop calculations


IBC 2015 907.1.1 - 907.1.2


The location of remotely located power supplies shall be -
Answer-Identified at the master control unit


NFPA 72 10.6.8

,2|Page


A contractor installed sprinkler heads to protect the
elevator hoistway. the sprinkler heads are rated at 150-
degrees Fahrenheit. the plans show heat detectors will be
installed in the hoistway to shut down elevator power prior
to sprinkler operation. what requirements are required for
the heat detectors? - Answer-Heat detectors shall have a
lower temperature rating than the sprinkler heads and
installed within 24 inches of each other


NFPA 72 21.4 - 21.4.2


A community college is what type of occupancy
classification? - Answer-Group B


IBC 2015, Section 302


A covered shopping center (mall) has a total floor area of
75,000 square feet. According to the IBC, what are the fire
alarm system requirements for this building? - Answer-An
emergency voice/alarm communication system shall be
provided


IBC, 402.7.4, 907.2.20

,3|Page




Which best describes the power supply requirements,
under specific conditions, that can be used as the sole
power source of a low-power radio transmitter? - Answer-A
primary, dry cell, battery


NFPA 72, 23.16 - 23.16.2


Where fire pumps are required to be monitored and a
building fire alarm system is installed, a pump running
signal shall be? - Answer-a supervisory or alarm signal


NFPA 72 23.8.5.9.1


A licensed electrician was hired to install duct detectors
mounted on the air ducts of a 5,000 CFM unit. Which of
the following statements is true? - Answer-The smoke
detector must be listed for use in air duct, the detectors
can initiate a supervisory signal and alarm signal


NFPA 72, duct detectors

, 4|Page


Record drawings, as built shall contain approval
documentation resulting from any? - Answer-Variances,
performance-based designs, and risk analysis


NFPA 72, record drawings


An electrically locked door is connected to the fire alarm
system in order to unlock in event of an alarm. The
customer has requested that a feature be added (push
button) to lock the doors even while in alarm. Is this
permitted by code? - Answer-No


NFPA 72, electrically locked doors


A pathway shall be designated as __________ when it is
not monitored for integrity. - Answer-Class E


NFPA 72, pathways


A sprinkler waterflow detector was installed on a sprinkler
branch of a low-rise apartment building. Upon testing, the
waterflow activated the alarm in 130 seconds. is this
acceptable as per NFPA 72? - Answer-No

Geschreven voor

Instelling
Fire Alarm Level II
Vak
Fire Alarm Level II

Documentinformatie

Geüpload op
17 september 2025
Aantal pagina's
33
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$25.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
ExcellentExams Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
19
Lid sinds
2 jaar
Aantal volgers
2
Documenten
3395
Laatst verkocht
1 dag geleden
EXCELLENT HOMEWORK HELP AND TUTORING ,ALL KIND OF QUIZ AND EXAMS WITH GUARANTEE OF A+

You will get solutions to all subjects in both assignments and major exams. Contact me for any assisstance. Good luck! Simple well-researched education material for you. Expertise in Nursing, Mathematics, Psychology, Biology etc,. My Work contains the latest, updated Exam Solutions, Study Guides, Notes 100% verified Guarantee.

3.3

4 beoordelingen

5
2
4
0
3
0
2
1
1
1

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen