C 39 ROOFING TRADE TEST 1 | QUESTIONS AND
CORRECT ANSWERS | ALREADY GRADED A+ |
VERIFIED ANSWERS | LATEST VERSIONS
Composition flashing (base flashing) should be fastened with: - (ANSWER)One-
inch solid cap-head nails or
Nails driven theough tin disks
Pitch pockets or pitch boxes: - (ANSWER)Are not recommended because they
require extensive maintenance
Reinforced concrete can be used as a structural deck. Which of the following is a
correct statement? - (ANSWER)Some moisture will remain in concrete decks even
after the surface is dry
Roofing insulation and membranes must be protected from latent moisture in
concrete decks. In northern climates, this is usually accomplished with: -
(ANSWER)A vapor retarder or
A venting sheet
Steel decks should be at least _______ or heavier. - (ANSWER)22g
, 2
Insulation applied to steel roof decks before the roof membrane is installed
should be applied: - (ANSWER)In two separate layers where insulation thickness
permits
The top flanges of a steel roof deck should be installed: - (ANSWER)Perpendicular
to the roof slope
The maximum deflection allowed for a steel deck is: - (ANSWER)1/4" per 100 feet
If the steel decks must be spot-welded to structural steel, puddle welds _______
or larger in diameter are recommended. They should be made on washers and
spaced at least _______ on center. - (ANSWER)1/2 inches ... 12 inches
If thermosetting insulation is used over structural decks, the density should be: -
(ANSWER)18 to 22 pounds per cubic foot
The correct density for thermosetting insulation is accomplished by: -
(ANSWER)Compacting
Thermosetting insulation is compacted in two layers if the total thickness is
greater than: - (ANSWER)6 inches
Thermosetting insulative fills must be protected from latent moisture in roof
decks. Which of the following procedures is recommended? - (ANSWER)Install
base-ply vapor barrier and