Page|1




TSSA G2 ACTUAL EXAM Q&A TESTED AND
APPROVED NEWLY MODIFIED EXAM
GRADED A+


Before lighting a burner in a steam boiler, ensure that:

A. there is water in the boiler

B. the temperature controller is set properly

C. the main burner test firing valve is turned on

D. the safety valves are open -- ANSWER--A




The recommended water temperature setting from a mixing valve to the domestic water
system in combination heating systems that employ oil-fired water heaters for heating potable
water and for space heating is:

A. 43°C (110°F)

B. 49°C to 54°C (120°F to 130°F)

C. 60°C to 66°C (140°F to 150°F)

D. 83°C (180°F) -- ANSWER--B




An inverted sensor (measures water level) can be found operating what type of appliance?

A. Hot water boiler

, Page|2




B. Steam water boiler

C. Domestic hot water storage tank

D. Domestic potable hot water tank -- ANSWER--D




A backflow prevent used in a hydronic heating system is used to:

A. Keep hot water from entering the cold water system

B. Hold the pressure on the system during a temporary shutdown to prevent the entry of air

C. Prevent the heating water from circulating the wrong way in the system

D. Keep non-combustible water from entering the drinking water system -- ANSWER--D




A low water cut off device on an automatically fired hot water heating boiler rated at 350,000
Btuh (102 kW) is:

A. Not required if a limit control is installed

B. Not required if it is installed in the industrial application

C. Required when any portion of the circulating system is located below the boiler D.
Required only in commercial applications -- ANSWER--C



A pressure reducing valve

A. Relieves system pressure in excess of the set pressure

B. Reduces the city main pressure to a safe working pressure

, Page|3




C. Reduces the working pressure to the city main pressure

D. Prevents hot water gravity circulation -- ANSWER--B




The maximum operating pressure of a low pressure steam boiler is

A. 5 psig (35kPa)

B. 15 psig (100 kPa)

C. 100 psig (690 kPa)

D. 150 psig (1035 kPa) -- ANSWER--B




A scotch marine boiler is what type of boiler?

A. Two pass boiler

B. Copper tube boiler

C. Fire tube boiler

D. Four pass water tube boiler -- ANSWER--C




A fire tube boiler has:

A. Water outside the tube and flue gases outside

B. Water inside the tubes and flue gasses outside

C. Water inside the tubes and water outside

, Page|4




D. Water outside the tubes and flue gases inside -- ANSWER--D




Why is a pressure relief valve installed on a pool heater system?

A. To maintain the pool water level

B. To prevent over pressurizing the filter

C. To prevent damage to the system

D. To relieve excess water pressure caused by solar gun -- ANSWER--C




When does an electrically operated automatic vent damper on a mid-efficiency furnace open?

A. Before the ignition cycle

B. When the furnace is hot

C. At the same time as the gas comes on

D. When the main switch is turned on -- ANSWER--A




What is the minimum distance the vent of a Category 4 furnace with an input under 100,000
Btuh can terminate from a combustion air inlet of any other appliance?

A. 12"

B. 36"

C. 60"

Geschreven voor

Vak

Documentinformatie

Geüpload op
21 september 2025
Aantal pagina's
137
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$26.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
TESTBANKNURSEHUB
4.0
(2)

Maak kennis met de verkoper

Seller avatar
TESTBANKNURSEHUB Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
8
Lid sinds
8 maanden
Aantal volgers
0
Documenten
3097
Laatst verkocht
2 weken geleden
your document plug

I offer all types of documents notes, exams and study guide practice exams. Feel free to contact me for any clarification and document prices.

4.0

2 beoordelingen

5
0
4
2
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen