Voorbeeld van de inhoud

NICET Fire Alarm Level II Actual Exam Prep Material Newest 2025/2026 Complete
Questions And Correct Answers (Verified Answers)|Brand New Version!





The International Mechanical Code requires a duct smoke detector in the return for units over ________
cfm - (ANSWER)2000 cfm



The International Mechanical Code (IMC) requires a duct smoke detector in the supply for units over
__________ cfm - (ANSWER)15000



Digital alarm communicator transmitters (DACT) which use call forwarding to the DACR shall be tested
with what frequency? - (ANSWER)4 hours



NPLFA cables shall be insulated to __________ v - (ANSWER)600v



PLFA cables shall be insulated to _______ v - (ANSWER)300v



For sprinkler systems what type of signal is a fire pump running?

a. alarm

b. supervisory

c. trouble

d. A and B - (ANSWER)d



A positive alarm sequence requires the approval of the ___________. - (ANSWER)AHJ



How often shall a remote annunciator used at the main entrance of a low-rise residential apartment
building be inspected? - (ANSWER)Semniannually



According to NFPA 72, the off-normal signal of a tamper switch control valve used in sprinkler piping
that is required for pressure-actuated water flow alarm switch, shall not be restored at any valve
position except _____________? - (ANSWER)Normal

,NICET Fire Alarm Level II Actual Exam Prep Material Newest 2025/2026 Complete
Questions And Correct Answers (Verified Answers)|Brand New Version!





When installing a heat-sensing fire detector on the bottom of a beam, the beam must be less than
_____________ inches in depth and _____________ feet on center? - (ANSWER)12 in; 8 ft



Where a door is released to provide a 2-hour fire rating directly from the smoke detector, the detector
shall be ______________

a. mounted as close as possible to the door being released

b. listed for door releasing service

c. identified for door releasing service

d. of the photoelectric type only - (ANSWER)b



According to NFPA, smoke detectors installed in the ducts of HVAC systems shall initiate:

a. alarm

b. supervisory

c. trouble

d. a or b - (ANSWER)d



According to the IBC, shop drawings shall include:

a. floor plan that indicates the use of all rooms

b. annunciators

c. voltage drop calculations

d. all of the above - (ANSWER)d



The location of remotely located power supplies shall be identified at the ________________ -
(ANSWER)Master Control Unit



Heat detectors will be installed in an elevator hoistway to shut down power to the elevator prior to
sprinkler activation. The heat detectors need to have a _______________ temp rating and shall be
located ______________ in from the sprinkler head. - (ANSWER)lower; 24 in

,NICET Fire Alarm Level II Actual Exam Prep Material Newest 2025/2026 Complete
Questions And Correct Answers (Verified Answers)|Brand New Version!






A local community college is what type of occupancy classification? - (ANSWER)Group B



What type of occupancy group for a school below the 12th grade? - (ANSWER)Group E



What type of occupancy group for a school above the 12th grade? - (ANSWER)Group B



A pathway shall be designated as _______________ (what class?) when it is NOT monitored for
integrity? - (ANSWER)Class E



Manual fire alarm boxes shall be installed on both sides of grouped openings over ____________ feet in
width and within __________ feet of each side of the grouped opening. - (ANSWER)40 feet; 5 feet



A fire pump was installed in a low-rise residential building with a required fire alarm system. What are
the requirements for the pump running signal?

a. It shall be a supervisory signal.

b. It shall be an alarm signal.

c. It shall be a supervisory or alarm signal.

d. A pump running signal is not required. - (ANSWER)c



A licensed electrician was hired to install duct detectors mounted on the air ducts of a 5,000 CFM unit.
Which of the follwoing statements is true?

a. The smoke detector must be listed for use in air ducts

b. The detectors can initiate a supervisory signal

c. The detectors can initiate an alarm signal

d. All of the above - (ANSWER)d



Record drawings, as-builts, shall contain approval documetnation resulting from any _______________?

, NICET Fire Alarm Level II Actual Exam Prep Material Newest 2025/2026 Complete
Questions And Correct Answers (Verified Answers)|Brand New Version!





a. variances

b. performance-based designs

c. risk analysis

d. all of the above - (ANSWER)d



An electrically locked door is connected to the fire alarm system in order to unlock in the event of an
alarm. The customer has requested that a feature be added (push button) to lock the doors even while
in alarm. Is this permitted by code? - (ANSWER)No



According to the 2022 edition of NFPA 13, electric waterflow devices must activate within
_________________ of water flow beginning and continue until the flow stops - (ANSWER)90 seconds



According to teh IBC, strobe lights/appliances shall not be required in ______________? -
(ANSWER)Elevator cars



Communications wires (Coaxial cables) shall have a voltage rating of not less than _________ volts -
(ANSWER)300v



What is the minimum workspace width in front of electrical equipment (This allows enough room for a
person to face the equipment without having to turn the upper body to work on the equipment)? -
(ANSWER)30 in



If a heat detector with a listed spacing of 50 feet is to be mounted on an 18′ high ceiling, what is its
maximum allowable spacing? - (ANSWER)35.5 ft



What is the maximum distance a heat detector can be from any point on a smooth ceiling? -
(ANSWER)0.7 times the listed spacing



A plate type grounding electrode must be at least_______below the surface of the earth. - (ANSWER)30
in

Geschreven voor

Instelling
NICET Fire Alarm Level II
Vak
NICET Fire Alarm Level II

Documentinformatie

Geüpload op
22 september 2025
Aantal pagina's
57
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$14.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Testmister Teachme2-tutor
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
2662
Lid sinds
1 jaar
Aantal volgers
2
Documenten
1190
Laatst verkocht
3 dagen geleden
Testmister: Expert-Level Study Resources

Welcome to the official repository for Testmister’s academic resources. As an experienced contributor to the tutoring community, I understand the logic behind effective learning. These documents aren't just notes—they are structured roadmaps designed to help you master your curriculum. Inside the collection: Comprehensive Summaries: Essential information synthesized for maximum retention. Practice Sets: Sharpen your skills with exam-style questions. Curated Bundles: Save time and effort with specialized package deals. You are sure to find exactly what you need to succeed. Follow this profile to stay updated on new uploads!

Lees meer Lees minder
5.0

509 beoordelingen

5
502
4
2
3
3
2
0
1
2

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen