S-12 CITYWIDE SPRINKLER SYSTEMS, S12
sprinkler test Exam 2025 (Actual Exam) Questions
with verified Answers (Latest Update 2025)
UPDATE!!
Save
Terms in this set (194)
THE __________ IS OWNER
RESPONSIBLE TO
MAINTAIN SPRINKLER
SYS. AND TO DETERMINE
QUALIFICATIONS.
RECORDS OF ALL 3
INSPECTIONS AND MX
SHALL BE MAINTAINED
ON PREMISES FOR A
MIN. OF __________ YEARS.
THE BUILDING OWNER IMPAIRMENT COORDINATOR
SHALL ASSIGN A(N)
____________ TO COMPLY
WITH REQUIREMENTS.
https://quizlet.com/1081791380/s-12-citywide-sprinkler-systems-s12-sprinkler-test-exam-2025-actual-exam-questions-with-verified-answers-latest-up… 1/30
,9/24/25, 3:14 PM S-12 CITYWIDE SPRINKLER SYSTEMS, S12 sprinkler test Exam 2025 (Actual Exam) Questions with verified Answers (Latest Up…
REGULAR MX AND 1
MINOR REPAIRS NOT
AFFECTING MORE THAN
________ FLOOR(S) ARE
CONSIDERED PLANNED
REMOVAL FROM
SERVICE.
SHUTDOWNS 1
AFFECTING MORE THAN
_________ FLOOR(S) ARE
CONSIDERED
UNPLANNED OUT OF
SERVICE CONDITIONS.
NOTIFICATION TO FDNY 8
IS NOT REQUIRED,
PROVIDED SYSTEM IS
RETURNED TO SERVICE
WITHIN ______ HOURS.
FOR UNPLANNED OWNER OF THE BUILDING
REMOVAL FROM
SERVICE, THE COF
HOLDER SHALL
IMMEDIATELY REPORT
CONDITION TO THE
___________ AND THE FIRE
DEPT.
IF A MINOR DEFECT IS 30
OBSERVED, IT SHALL BE
CORRECTED WITHIN
_________ DAYS OR IT WILL
BE CONSIDERED AN
IMPAIRMENT.
WHAT DOES "OOS" OUT OF SERVICE
STAND FOR?
https://quizlet.com/1081791380/s-12-citywide-sprinkler-systems-s12-sprinkler-test-exam-2025-actual-exam-questions-with-verified-answers-latest-up… 2/30
, 9/24/25, 3:14 PM S-12 CITYWIDE SPRINKLER SYSTEMS, S12 sprinkler test Exam 2025 (Actual Exam) Questions with verified Answers (Latest Up…
OOS SYSTEMS SHALL BE TAGS
IDENTIFIED BY PLACING
________ AT FIRE DEPT.
CONNECTIONS, SYS.
CONTROL VALVES, AND
FIRE COMMAND CENTER
A _______ SHALL BE MASTER FIRE SUPPRESSION PIPING CONTRACTOR
REQUIRED TO POST TAGS
AT MAIN CONTROL
VALVE AND ANY
SECTIONAL VALVES.
__________ SHALL BE POSTED DRAIN TEST RESULTS
ON THE TAG INDICATING
BOTH STATIC AND FLOW
PRESSURES BEFORE AND
AFTER.
GREEN TAGS INDICATE NO IMPAIRMENT WAS FOUND
THAT __________.
GREEN TAGS WILL BE MAIN CONTROL VALVE
PLACED ON THE ____________.
SYSTEMS PARTIALLY OR RED
FULLY OUT OF SERVICE
SHALL HAVE A ____________
TAG PLACED ON THE
MAIN CONTROL VALVE.
A _________ DISC OF 8-9 WHITE
INCHES SHALL BE
PLACED ON
CONNECTIONS TO
INDICATE THE SYSTEM IS
FULLY OUT OF SERVICE.