Med gas 3 EXAM ALL QUESTIONS AND CORRECT ANSWERS|ALREADY GRADED A+ Main branches in medical gas piping systems shall not be less than what? A) 3/4 N.P.S., B) 5/8 N.P.S., C) 1/2 N.P.S., D) 3/8 N.P.S. - Answer- C) 1/ 2. N.P.S. Mains and branches in medical surgical vacuum systems shall not be less than what? A) 7/8, N.P.S. B) 3/4 N.P.S., C) 5/8 N.P.S., D) 1/2 N.P.S. - Answer- B) 3/4 N.P.S. Run out to alarm panels in connecting tubing for gauges alarm devices shall be permitted to be what ? A) 1/4 N.P.S., B) 3/8 N.P.S., C) 1/8 N.P.S., D) 1/16 N.P.S. - Answer- A) 1/4 N.P.S. Piping shall not be installed at which of the following locations? A) kitchens. B) elevator shafts. C) areas with open flame. D) all of the above - Answer- D) all of the above Hangers for copper to Shelby plastic coated, copper finishes or otherwise insulated from the tube. true or false - Answer- True Underground piping buried outside of the building shall be installed below the Local frost the penetration and shall be protected by a what? A) conduit. B) enclosure. C) cover. D) any of the above - Answer- D) Any of the above The minimum vas still covered for buried piping Shelby 36 inch, except that the minimum cover she'll be reduced to what where physical damage is otherwise prevented. A) 24 ". B) 20". C) 18". D) 16" - Answer- D) 18" A continuous tape or markers shall be placed immediately above the buried pipeline enclosure and she'll be identified by? A) color code. B) faculty numbering. C) chemical symbol. D) Specific name. - Answer- D) specific name Freezing procedures and brazier performance for the installation of medical gas and vacuum piping shall be qualified in accordance with? A) A.S.M.E. Section 1X . B) A.S.S.E Standard 6010. C) A.W.S. B 31.3, D) none of the above - Answer- A) A.S.M.E. section 1X To identify medical gas or vacuum system piping, the piping shall be labeled by? A) stencil name of system. B) adhesive markers. C) stencil name by chemical symbols. D) any of the above. - Answer- D) any of the above Which of the following hazards she'll be considered in the design, insulation, testing and maintenance of medical vacuum piping system? A) contamination. B) fire and smoke. C) fire and explosion. D) water in gas - Answer- C) fire and explosion Liquid containers shall have an additional product identification visible from all directions within a minimum of what hi letters such as 360 degree wrap around tape for medical liquid containers. A) 1 ", B) 2", C) 3", D) 4" - Answer- B) 2" Which of the following system shall not be permitted to be located in the same indoor enclosure? A) bulk cryogenic liquid system. B) manifold for cryogenica liquid cylinders. C) manifolds for gas cylinders with or without reserve. D) instrument air standby header - Answer- A) bulk cryogenic liquid system Locations for central supply systems and storage of medical gases shall be secured with lockable doors or gates? True or false - Answer- True Louvered openings for natural ventilation system shall have a free area of? A) 60 square inch. B) 62 square inch. C) 70 square inch. D) 72 square inch - Answer- D) 72 square inch A pressure relief valves Shelby made of brass, bronze or ? A) stainless steel. B) carbon steel. C) cast iron. D) copper - Answer- A) Stainless steel Relief valves shall be vented to the what,except compressed air systems shall have less than 3000 cubic feet at S.T.P., A) floor. B) sewer drain. C) back into the system. D) outside. - Answer- D) outside Manifolds for cryogenic liquid containers shall indicate when or at a predetermined set point. Before the reserved contents fall two a days average supply, indicating? A) Reserve is in use. B) primary empty. C) secondary empty. D) Reserve low. - Answer- D) Reserve low Installers of both cryogenic liquid systems she'll be qualified to meet C.G.A. M-1 standard, guide for medical gas installations at consumer sites. True or false - Answer- True Where the bulk cryogenix liquid oxygen supply system is outside of and remote from the building served, a what connection shall be installed. A) maintenance clean out. B) refilling. C) emergency oxygen supply. D) all the above - Answer- C) emergency oxygen supply Day in building emergency reserve system can be substituted for the E.O.S.C., true or false - Answer- True Compressors for medical air shall be designed to prevent introduction of contaminants or liquids into the piping system. True or false - Answer- True

Meer zien Lees minder
Instelling
Med Gas 3
Vak
Med gas 3

Voorbeeld van de inhoud

Med gas 3 EXAM ALL QUESTIONS
AND CORRECT ANSWERS|ALREADY
GRADED A+
Main branches in medical gas piping systems shall not be less than what? A) 3/4
N.P.S., B) 5/8 N.P.S., C) 1/2 N.P.S., D) 3/8 N.P.S. - Answer- C) 1/ 2. N.P.S.

Mains and branches in medical surgical vacuum systems shall not be less than what?
A) 7/8, N.P.S. B) 3/4 N.P.S., C) 5/8 N.P.S., D) 1/2 N.P.S. - Answer- B) 3/4 N.P.S.

Run out to alarm panels in connecting tubing for gauges alarm devices shall be
permitted to be what ? A) 1/4 N.P.S., B) 3/8 N.P.S., C) 1/8 N.P.S., D) 1/16 N.P.S. -
Answer- A) 1/4 N.P.S.

Piping shall not be installed at which of the following locations? A) kitchens. B) elevator
shafts. C) areas with open flame. D) all of the above - Answer- D) all of the above

Hangers for copper to Shelby plastic coated, copper finishes or otherwise insulated from
the tube. true or false - Answer- True

Underground piping buried outside of the building shall be installed below the Local frost
the penetration and shall be protected by a what? A) conduit. B) enclosure. C) cover. D)
any of the above - Answer- D) Any of the above

The minimum vas still covered for buried piping Shelby 36 inch, except that the
minimum cover she'll be reduced to what where physical damage is otherwise
prevented. A) 24 ". B) 20". C) 18". D) 16" - Answer- D) 18"

A continuous tape or markers shall be placed immediately above the buried pipeline
enclosure and she'll be identified by? A) color code. B) faculty numbering. C) chemical
symbol. D) Specific name. - Answer- D) specific name

Freezing procedures and brazier performance for the installation of medical gas and
vacuum piping shall be qualified in accordance with? A) A.S.M.E. Section 1X . B)
A.S.S.E Standard 6010. C) A.W.S. B 31.3, D) none of the above - Answer- A) A.S.M.E.
section 1X

To identify medical gas or vacuum system piping, the piping shall be labeled by? A)
stencil name of system. B) adhesive markers. C) stencil name by chemical symbols. D)
any of the above. - Answer- D) any of the above

, Which of the following hazards she'll be considered in the design, insulation, testing and
maintenance of medical vacuum piping system? A) contamination. B) fire and smoke.
C) fire and explosion. D) water in gas - Answer- C) fire and explosion

Liquid containers shall have an additional product identification visible from all directions
within a minimum of what hi letters such as 360 degree wrap around tape for medical
liquid containers. A) 1 ", B) 2", C) 3", D) 4" - Answer- B) 2"

Which of the following system shall not be permitted to be located in the same indoor
enclosure? A) bulk cryogenic liquid system. B) manifold for cryogenica liquid cylinders.
C) manifolds for gas cylinders with or without reserve. D) instrument air standby header
- Answer- A) bulk cryogenic liquid system

Locations for central supply systems and storage of medical gases shall be secured
with lockable doors or gates? True or false - Answer- True

Louvered openings for natural ventilation system shall have a free area of? A) 60
square inch. B) 62 square inch. C) 70 square inch. D) 72 square inch - Answer- D) 72
square inch

A pressure relief valves Shelby made of brass, bronze or ? A) stainless steel. B) carbon
steel. C) cast iron. D) copper - Answer- A) Stainless steel

Relief valves shall be vented to the what,except compressed air systems shall have less
than 3000 cubic feet at S.T.P., A) floor. B) sewer drain. C) back into the system. D)
outside. - Answer- D) outside

Manifolds for cryogenic liquid containers shall indicate when or at a predetermined set
point. Before the reserved contents fall two a days average supply, indicating? A)
Reserve is in use. B) primary empty. C) secondary empty. D) Reserve low. - Answer- D)
Reserve low

Installers of both cryogenic liquid systems she'll be qualified to meet C.G.A. M-1
standard, guide for medical gas installations at consumer sites. True or false - Answer-
True

Where the bulk cryogenix liquid oxygen supply system is outside of and remote from the
building served, a what connection shall be installed. A) maintenance clean out. B)
refilling. C) emergency oxygen supply. D) all the above - Answer- C) emergency oxygen
supply

Day in building emergency reserve system can be substituted for the E.O.S.C., true or
false - Answer- True

Compressors for medical air shall be designed to prevent introduction of contaminants
or liquids into the piping system. True or false - Answer- True

Geschreven voor

Instelling
Med gas 3
Vak
Med gas 3

Documentinformatie

Geüpload op
25 september 2025
Aantal pagina's
5
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$13.94
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Stuviaascorers University of Washington
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
368
Lid sinds
3 jaar
Aantal volgers
185
Documenten
11068
Laatst verkocht
1 week geleden
StuviaAscorers | Top Study Notes & Exam Solutions

Stuviaascorers – Your #1 Source for Top-Quality Study Materials! Struggling with exams? Stuviaascorers has got you covered! I provide expertly crafted study notes, summaries, past papers, and exam-ready answers to help you pass with flying colors. My materials are designed for clarity, accuracy, and success—so you can study smarter, not harder! Why Choose My Study Materials? Well-structured & easy to understand – No fluff, just what you need! Exam-focused & high-scoring content – Get straight to the point! Accurate answers & clear explanations – Learn with confidence! Save time & boost your grades – Study efficiently! Don’t leave your success to chance! Browse my documents and start acing your exams today!

Lees meer Lees minder
3.8

65 beoordelingen

5
31
4
11
3
11
2
2
1
10

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen