Michigan Builders License Exam Questions And Answers.




Created to serve as a complete, comprehensive code regulating the construction of
single-family, two-family and buildings consisting of three or more townhouse units. -
answer;-IRC (International Residential Code)

Administrative - answer;-First 2 chapters of code book are

True - answer;-Plans or supporting documents are almost always required by the
controlling authority prior to issuing a permit. T or F

Yes - answer;-Does the building official have the authority to render interpretations of
the code?

8 foot fence. - answer;-None of the following require a permit, EXCEPT:
sidewalks and driveways
tiling
an 8 foot fence
playground equipment

False - answer;-Tables and illustrations are always supported by information found in
the written code and footnotes. T or F

Live load. - answer;-The amount of evenly distributed weight imposed by inhabitants,
goods and removable objects on a floor or roof system is referred to as

True. - answer;-If a code requirement is in the book, it is both acceptable and
enforceable by the code official. T or F

Figures. - answer;-Illustrations are typically referred to as

Determine that buildings are built to the minimum enforceable standard. - answer;-
Generally speaking, the building official's job is to

True. - answer;-It is required that all manufacturer instructions be at the jobsite at the
time of inspection. T or F

Kitchen. - answer;-All of the following are not considered habitable spaces EXCEPT:
bathrooms
kitchens
storage spaces
closets

3. - answer;-Bathrooms must be provided with an aggregate glazing area no less than
_____ square feet, half of which must be openable.

,Michigan Builders License Exam Questions And Answers.




44 inches. - answer;-The maximum height of an egress window above the floor is

5.7 sq ft. - answer;-A basement bedroom must have an egress window with a clear
opening of at least ______ square feet.

3. - answer;-At least one side-hinged exit door must be in each dwelling unit, and must
be _____ feet wide.

30 inches. - answer;-A porch more than _____ inches above grade must be provided
with 36" guards.

200. - answer;-Wall and ceiling finishes shall have a flame-spread classification of no
more than ______ .

7 days. - answer;-According to code, concrete must reach at least 70% of it's ability
within ____________days.

40%. - answer;-A stud used for a non-bearing partitions may not be notched more than
____% of the stud width.

Additions, alterations, renovation and repairs. - answer;-The Michigan Uniform Energy
code applies to new buildings as well as

U-factor. - answer;-___________ is a measure of how well the window or door
assembly conducts heat. The lower the number, the better insulation the assembly will
provide.

50%. - answer;-Energy losses from recessed lighting fixtures can often reach ___% of
the total thermal loss of a ceiling.

R-3. - answer;-Michigan requires a minimum thermal resistance of ____________for
mechanical system piping.

True. - answer;-Oversized HVAC equipment has a higher initial cost, a higher operating
cost, provides less comfort, and shorter life expectancy. T or F

Prescriptive Path. - answer;-_______ is the compliance route that applies Table 402.1.1
to building envelope components, and is considered the most simple.

Area weighted averages. - answer;-___________ can be used to satisfy U-factor and
SHGC requirements.

IC (Insulation Contact) - answer;-Recessed lights must be _____ rated.

,Michigan Builders License Exam Questions And Answers.




True. - answer;-Up to 15 square feet of glazing per dwelling unit is exempted from U-
value requirements. T or F

Registered design professional. - answer;-The 2009 IECC requires a permanent
certificate posted on the electrical distribution panel. The certificate shall be completed
by the builder or

State energy code requirements. - answer;-One hurdle contractors face when bidding
for an energy efficient project is choosing materials that fit the design, and also meet

False. - answer;-Historically significant buildings are not exempt from code changes. T
or F

R-value
Settled thickness
Manufacturer name - answer;-Insulation products (blown and sprayed) must be
documented with:

March 2011. - answer;-The new Michigan codes took effect in

10. - answer;-Below grade walls are insulated from the top of the basement wall down
to _____ below grade, or the basement floor, whichever is less.

Area weighted average. - answer;-The _______ is the combined Solar Heat Gain
Coefficient of all the glazed fenestration products in the building.

Thermal insulation R-values
Design criteria
Equipment systems - answer;-Plans and specifications must be detailed in regards to:

2009. - answer;-In Michigan, the residential energy code is based on the _____ IECC,
with certain amendments.

Air leakage. - answer;-___________ is the rate of air infiltration in the presence of a
specific pressure differential.

Windows
Attic access hatches
Recessed lights - answer;-Air leakage is the random movement of air into and out of
________ through cracks and holes.

Table 402.1.1
2009 IECC - answer;-R-values for insulation and fenestration requirements by
component can be found in

, Michigan Builders License Exam Questions And Answers.




International Energy Conservation Code - answer;-IECC

U-factor and UA alternatives. - answer;-The _____________ compliance method allows
for more innovative construction techniques like SIPs or Advanced Framing.

500 sq feet - answer;-R-30 is permitted in vaulted ceilings, but is limited to

True. - answer;-Floor insulation must be installed to maintain permanent and continuous
contact with the underside of the subfloor decking. T or F

5, 6 and 7. - answer;-Michigan falls into climate zones

False. - answer;-It is permissible for supply ducts to be run through the framing cavities
of a residential building. T or F

IC rated (Insulation Contact) - answer;-__________ means an electrical fixture has
been tested and listed as suitable for installation in a cavity where the fixture may come
in contact with insulation.

3%. - answer;-According to the Dept. of Energy, improved energy codes could reduce
CO2 emissions by

300 sq ft. - answer;-Attic insulation markers must be installed every _____ square feet.

True. - answer;-Buildings that are exempted from the new regulations are those with
very low energy use or ones that are neither heated or cooled. T or F

Yes. - answer;-A contractor needs to remove a non-load bearing wall, does he need to
pull a permit?

No. - answer;-A concrete contractor has been hired by an owner to install a driveway
and sidewalks. The lot is flat and the concrete is being place on undisturbed earth with a
prepared base. Does the contractor need to pull a permit?

Yes. - answer;-A permit has been issued for a building project and there is a code
infraction in the building plans that has been overlooked by the building official. Can the
building official require a correction to a project that they previously overlooked?

Health department. - answer;-Who issues a well and septic permit?

200 sq. feet.
IRC R105 - answer;-Permits are not required for one story detached accessory
structures not exceeding:

Geschreven voor

Vak

Documentinformatie

Geüpload op
27 september 2025
Aantal pagina's
54
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$10.69
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
bryanwalker859

Maak kennis met de verkoper

Seller avatar
bryanwalker859 All Types of Notes
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
1
Lid sinds
10 maanden
Aantal volgers
0
Documenten
145
Laatst verkocht
6 maanden geleden

0.0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen