1



NFPA 24 TEST (TFM10) EXAM QUESTIONS AND
ANSWERS NEW MODIFIED TESTED AND
APPROVED



This standard shall apply to ______ intended to carry water
for fire service mains --ANSWER--Combined Service Mains



Working plans shall be submitted for approval to the _____
before any equipment is installed or remodeled. --ANSWER--
AHJ



____ shall not be used --ANSWER--Pressure-Regulating
devices



______ shall not be installed in the piping from the fire
department connection to the fire service main --ANSWER--
Control Valves

, 2



_____ shall be permitted in the system downstream of the fire
department connection --ANSWER--Control Valves



When more than one water supply exists, a ___________
shall be installed in each connection --ANSWER--Check
Valve



All check valves shall have a ________ installed upstream
and downstream of the check valve. --ANSWER--Control
Valve



A post indicator valve installed not less than____ from the
building --ANSWER--40 ft



Where post indicator valves are used, they shall be set so that
the top of each post is _______ above final grade --
ANSWER--32-40 inches

, 3



Supervision of underground gate valves with roadway boxes
shall ____________ --ANSWER--not be required



The connection from the hydrant to the main shall
___________ --ANSWER--not be less than 6 inches



Hydrants shall be located _________ from the buildings to be
protected --ANSWER--not less than 40 ft



Hydrants shall be installed on __________ --ANSWER--flat
stones, concrete slabs, or other approved material



The center of a hose outlet shall not be ____________ above
final grade --ANSWER--less than 18 inches



The center of a hose outlet shall not be _______ above final
grade --ANSWER--more than 36 inches

, 4



All piping used in private fire service mains shall be rated for
the maximum system working pressure to which the piping is
exposed to but shall not be rated at _______________ --
ANSWER--less than 150 psi



All bolted joint accessories shall be cleaned and thoroughly
coated with _______________ after installation --ANSWER--
asphalt or other corrosion-retarding material



In locations where freezing is not a factor, the depth of cover
shall __________________ below grade to prevent
mechanical damage. --ANSWER--not be less than 30 inches



Private fire service mains installed under driveways or
roadways shall be buried at a ______________ --ANSWER--
minimum depth of 36 inches



Where private fire mains extend more than 10 ft into the
building, they shall be ___________ --ANSWER--run in a
covered trench

Written for

Course

Document information

Uploaded on
September 28, 2025
Number of pages
38
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$26.09
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller
Seller avatar
TESTBANKNURSEHUB
4.0
(2)

Get to know the seller

Seller avatar
TESTBANKNURSEHUB Chamberlain College Of Nursing
Follow You need to be logged in order to follow users or courses
Sold
8
Member since
8 months
Number of followers
0
Documents
3097
Last sold
2 weeks ago
your document plug

I offer all types of documents notes, exams and study guide practice exams. Feel free to contact me for any clarification and document prices.

4.0

2 reviews

5
0
4
2
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions