QUESTIONS AND CORRECT DETAILED ANSWERS
(EXPERT VERIFIED) FOR GUARANTEED PASS|TOP
Page | 1
RATED A+.
IICRC WRT
Pass your IICRC Water Restoration Technician (WRT) 2025/2026
Exam with confidence. This exam resource evaluates your
understanding of water damage restoration principles, including water
categories, classes of water damage, and drying techniques. It’s
essential for professionals seeking to advance in water damage
restoration.
#1. During the inspection process, restorers shall make a
reasonable effort to ....... ANSWER ........ C. identify
and address potential safety hazards
#2. A significant amount of water absorption and
evaporation load where wet porous materials represent ~5%
to ~40% of combined ceiling, walls, and flooring surface
areas and where low evaporation materials and assemblies
are minimally wet is ....... ANSWER ........ B. class 2
#3. Multiple extraction of salvageable materials, especially
porous material (e.g. Carpet , cushion) often are required to:
....... ANSWER ........ decrease drying time
, #4. To enhance drying, restorers should manage both
Page | 2
ambient temperature and ....... ANSWER ........ surface
temperatures of affected materials
#5. Water damage restoration services should not begin until
after the: ....... ANSWER ........ restorer has entered
into an adequately written contract.
#6. Two tools that should be used to properly disengage
most stretched-in carpet ....... ANSWER ........ Knee
kicker and carpet awl
#7. When inspecting a water damage structure, restorers
should inspect: ....... ANSWER ........ all potentially
affected areas.
#8. Buckled or damaged particle board should .......
ANSWER ........ removed and replaced with new
material.
#9. upon entering a building, professional moisture detection
equipment should be used to evaluate and document: .......
, ANSWER ........ applicable psychrometric conditions and
moisture content or level readings .
Page | 3
#10. When wet, a structural material that loses most of its
structural integrity, but regains its strength when dry, is:
....... ANSWER ........ Concrete
#11 Initially, a method of search for abnormal moisture
behind ceramic tile or resilient flooring can be accomplished
by ....... ANSWER ........ using a non-penetrating
(non-invasive) moisture meter
#12. To minimize damage and reduce drying time, reduce
drying time, restorers should: ....... ANSWER ........
begin mitigation as soon as safely possible
#13. The moisture content of structural materials should be
measured with a ....... ANSWER ........ A. moisture
meter
#14. When accessible from below, to dry wet wood
subflooring under stone or tile flooring, restorers can use low-