Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

Plumbing Code Exam Questions Answered Correctly Latest Update

Rating
-
Sold
-
Pages
44
Grade
A+
Uploaded on
29-09-2025
Written in
2025/2026

Plumbing Code Exam Questions Answered Correctly Latest Update Definition Any combination of fixtures, not to exceed one water closet, 2 lavs, either 1 bathtub or bath/ shower combo, and 1 shower. May include bidet & floor drain. - Answers Bathroom Group Definition A pipe that makes an angle of more than 45 degrees with the vertical is considered? - Answers Vertical Pipe A device and system of piping that maintains a water seal in a remote trap is called? - Answers Trap Primer Table 1002.2 The developed length of a 2" trap arm, from the trap weir to the inner edge of the vent shall not exceed how many feet? - Answers 5 feet Definition Having access thereto, but which first may require the removal of an access panel, door, or similar obstruction. - Answers Accessible Definition Having direct access without the necessity of removing a panel, door, or similar obstruction. - Answers Readily Accessible Table 703.2 How many Fixture Units may a 1 1/2" vent pipe serve? - Answers 8 fixture units Table 703.2 *Note 6 Vent piping should not exceed ___________ of the total permitted length horizontally. - Answers 1/3 Table 703.2 *Note 6 The vent shall not be less than _______ or _______. - Answers 1 1/4" or less than 1/2 the diameter of the drain. Definition Water at a temperature exceeding or equal to 100F - Answers Hot water Definition The slope or fall of a line of pipe in reference to a horizontal plane. - Answers Grade Definition The pipe carrying potable water from the water meter or other source of water supply to a building. - Answers Building Supply Definition A room equipped with only a water closet and lavatory. - Answers Half Bathroom Table 1002.2 The max distance of a 2" trap arm shall not exceed ____. - Answers 5 feet or 60" The scale on a set of plans is 1/8 inch= 1 foot. The actual length of a water line with plan of 5" would be ___________ feet. - Answers 40 feet The developed length of a 1 1/2" trap arm shall not exceed ______________. - Answers 3ft 6in or 42 inches What is the max fixture unit load size for a 2" horizontal drain? What is the max fixture unit load size for a 2" vertical drain? - Answers Horizontal: 8fu Vertical: 16fu 605.1.2 Flared Joints Flaring tools are used to make joints for __________ or _________. - Answers soft copper or copper alloy Who needs to inspect and approve the plumbing system before it is concealed and covered? - Answers Authority Having Jurisdiction (AHJ) 905.3 Vent Pipe Rise Vent pipes may offset horizontally when the distance above the overflow level of the fixture is not less than ____________. - Answers 6" 105.2.3 Inspection Requests The Authority Having Jurisdiction shall be permitted to require a ____________ notice before inspection. - Answers 24 hours 811.1 Pretreatment Copper tubing and fittings shall be permitted to be used with DWV systems except for ____________. - Answers Chemical waste How is Pex defined? - Answers Cross-linked polyethylene The max vertical distance for a tailpiece allowed between a fixture and the trap weir is _____________. - Answers 24" Each vent pipe or stack shall extend through its flashing and shall terminate vertically above the roof at least __________. - Answers 6 inches All indirect waste piping that requires an airgap shall discharge into the building drainage system through ______________. - Answers A drainage air gap of 1" minimum 604.13 Water Heater Connectors Pex tubing shall not be installed within the first __________ of piping connected to a water heater. - Answers 18" 706.3 Horizontal to Horizontal A horizontal drainage line connecting with other horizontal drainage lines shall enter through a __________, __________, __________, or other approved fittings of equivalent sweep. - Answers 45 degree wye branch, combo wye, one-eighth bend branches One gallon of water weighs approximately _______. - Answers 8.34 lbs 910.4 Size The cleanout for a 4" diameter drain pipe shall not be smaller than ________. - Answers 3 1/2" Stand pipe receptors for clothes washers shall extend above the trap no less than _______. - Answers 18 inches App A A104.1 The minimum residual water pressure that shall be maintained at the highest fixtures in the supply system shall not be less than ______. - Answers 8 psi Definition What is a trap that does not maintain a proper trap seal? - Answers Insanitary What is Chlorinated Polyvinyl Chloride? - Answers CPVC Definitions A quantity in terms of which the load production effects on the plumbing system. - Answers Fixture Units (FU) Is 95F considered hot water? - Answers No What is the condition that is contrary to sanitary principles or is injurious to health? - Answers Insanitary Definition The principal artery of a system of continuous piping to which banches may be connected - Answers Main 404.2 Overflows The overflow pipe from a fixture shall be connected on the _______________. - Answers House or inlet side of the trap 409.2 Waste Outlet The diameter of a waste outlet and fixture tailpiece of a bathtub shall not be less than ___________. - Answers 1 1/2" diameter Does unsanitary & insanitary share the same meaning? - Answers Yes

Show more Read less
Institution
Plumbing Code
Course
Plumbing Code

Content preview

Plumbing Code Exam Questions Answered Correctly Latest Update 2025-2026

Definition



Any combination of fixtures, not to exceed one water closet, 2 lavs, either 1 bathtub or bath/
shower combo, and 1 shower. May include bidet & floor drain. - Answers Bathroom Group

Definition



A pipe that makes an angle of more than 45 degrees with the vertical is considered? - Answers
Vertical Pipe

A device and system of piping that maintains a water seal in a remote trap is called? - Answers
Trap Primer

Table 1002.2



The developed length of a 2" trap arm, from the trap weir to the inner edge of the vent shall not
exceed how many feet? - Answers 5 feet

Definition



Having access thereto, but which first may require the removal of an access panel, door, or
similar obstruction. - Answers Accessible

Definition



Having direct access without the necessity of removing a panel, door, or similar obstruction. -
Answers Readily Accessible

Table 703.2



How many Fixture Units may a 1 1/2" vent pipe serve? - Answers 8 fixture units

Table 703.2

*Note 6

,Vent piping should not exceed ___________ of the total permitted length horizontally. - Answers
1/3

Table 703.2

*Note 6



The vent shall not be less than _______ or _______. - Answers 1 1/4"

or

less than 1/2 the diameter of the drain.

Definition



Water at a temperature exceeding or equal to 100F - Answers Hot water

Definition



The slope or fall of a line of pipe in reference to a horizontal plane. - Answers Grade

Definition



The pipe carrying potable water from the water meter or other source of water supply to a
building. - Answers Building Supply

Definition



A room equipped with only a water closet and lavatory. - Answers Half Bathroom

Table 1002.2



The max distance of a 2" trap arm shall not exceed ____. - Answers 5 feet

or

,60"

The scale on a set of plans is 1/8 inch= 1 foot. The actual length of a water line with plan of 5"
would be ___________ feet. - Answers 40 feet

The developed length of a 1 1/2" trap arm shall not exceed ______________. - Answers 3ft 6in

or

42 inches

What is the max fixture unit load size for a 2" horizontal drain?



What is the max fixture unit load size for a 2" vertical drain? - Answers Horizontal: 8fu



Vertical: 16fu

605.1.2 Flared Joints



Flaring tools are used to make joints for __________ or _________. - Answers soft copper or
copper alloy

Who needs to inspect and approve the plumbing system before it is concealed and covered? -
Answers Authority Having Jurisdiction (AHJ)

905.3 Vent Pipe Rise



Vent pipes may offset horizontally when the distance above the overflow level of the fixture is
not less than ____________. - Answers 6"

105.2.3 Inspection Requests



The Authority Having Jurisdiction shall be permitted to require a ____________ notice before
inspection. - Answers 24 hours

811.1 Pretreatment

, Copper tubing and fittings shall be permitted to be used with DWV systems except for
____________. - Answers Chemical waste

How is Pex defined? - Answers Cross-linked polyethylene

The max vertical distance for a tailpiece allowed between a fixture and the trap weir is
_____________. - Answers 24"

Each vent pipe or stack shall extend through its flashing and shall terminate vertically above the
roof at least __________. - Answers 6 inches

All indirect waste piping that requires an airgap shall discharge into the building drainage
system through ______________. - Answers A drainage air gap of 1" minimum

604.13 Water Heater Connectors



Pex tubing shall not be installed within the first __________ of piping connected to a water heater.
- Answers 18"

706.3 Horizontal to Horizontal



A horizontal drainage line connecting with other horizontal drainage lines shall enter through a
__________, __________, __________, or other approved fittings of equivalent sweep. - Answers 45
degree wye branch, combo wye, one-eighth bend branches

One gallon of water weighs approximately _______. - Answers 8.34 lbs

910.4 Size



The cleanout for a 4" diameter drain pipe shall not be smaller than ________. - Answers 3 1/2"

Stand pipe receptors for clothes washers shall extend above the trap no less than _______. -
Answers 18 inches

App A A104.1



The minimum residual water pressure that shall be maintained at the highest fixtures in the
supply system shall not be less than ______. - Answers 8 psi

Definition

Written for

Institution
Plumbing Code
Course
Plumbing Code

Document information

Uploaded on
September 29, 2025
Number of pages
44
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$11.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF


Also available in package deal

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TutorJosh Chamberlain College Of Nursing
Follow You need to be logged in order to follow users or courses
Sold
450
Member since
1 year
Number of followers
16
Documents
32010
Last sold
2 days ago
Tutor Joshua

Here You will find all Documents and Package Deals Offered By Tutor Joshua.

3.5

73 reviews

5
26
4
16
3
14
2
1
1
16

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions