2 VERSIONS COMPLETE EXAM QUESTIONS WITH DETAILED
VERIFIED ANSWERS (100% CORRECT ANSWERS) /ALREADY
GRADED A+
If workers are required to enter a trench over 1.2 m (4 ft) deep, the safe
point of entry and exit must be located:
a) within 8 m (25 ft) of the workers and the excavation must be
safely supported or sloped to the entry and exit location.
b) within 5 m (16 ft) of the workers and the excavation must be safely
supported or sloped to the entry and exit location.
c) within 7 m (23 ft) of the workers and the excavation must be safely
supported or sloped to the entry and exit location.
d) within 10 m (32 ft) of the workers and the excavation must be safely
supported or sloped to the entry and exit location. - (Correct Answer) -a
If workers are required to enter a trench over 1.2 m (4 ft) deep, the safe
point of entry and exit must be located:
a) within 5 m (16 ft) of the workers and the excavation must be safely
supported or sloped to the entry and exit location.
b) within 7 m (23 ft) of the workers and the excavation must be safely
supported or sloped to the entry and exit location.
c) within 8 m (25 ft) of the workers and the excavation must be
safely supported or sloped to the entry and exit location.
,d) within 10 m (32 ft) of the workers and the excavation must be safely
supported or sloped to the entry and exit location. - (Correct Answer) -c
What is the design and construction that prevents
water from ever entering?
a) Principle of driving rain deterrent
b) Principle of driving rain deflection
c) Principle of rainwater deterrent
d) Principle of rainwater deflection - (Correct Answer) -d
The higher grit number is equivalent to:
a) a finer abrasive, which creates smoother surface
finishes.
b) a finer abrasive, which creates a rougher surface finish.
c) a rougher abrasive, which creates smoother surface
finishes.
d) a rougher abrasive, which creates a rougher surface finish. - (Correct
Answer) -a
The vertical height of any flight of stairs shall not exceed
a) 4.5 m or 15 ft
b) 3.7 m or 12 ft
,c) 3.5 m or 11.5 ft
d) 2.8 m or 9 ft - (Correct Answer) -b
Extend the ladder at least ____ above the landing platform or the point of
support.
a) 1.5 m (5 ft)
b) 2 m (6.3 ft)
c) 1 m (3 ft)
d) .5 m (1.5 ft) - (Correct Answer) -c
for every four feet in height, the base of the ladder should be moved ___ foot
out from the wall or structure. - (Correct Answer) -1
Use a ___ ratio for setting ladders (approximately 75 degrees) to determine
how far out the base of the ladder should be moved in relation to the height
of the ladder against the wall. - (Correct Answer) -4:1
To be effective, mechanical ventilation systems must be able to
a) Distribute ventilation air to most rooms of the house and exhaust air from
kitchens, bathrooms, and laundry rooms.
b) Exhaust air from kitchens, bathrooms, and laundry rooms.
c) Distribute ventilation air to bedrooms and common spaces
, d) Distribute ventilation air to most bedrooms and exhaust air from
bathrooms and laundry rooms. - (Correct Answer) -a
____________ performs routine remote and physical inspections on gas work
and gas equipment in commercial, industrial, and residential premises.
a) Worksafe BC
b) Regional District Building Inspectors
c) Technical Safety BC - (Correct Answer) -c
If your property is in Technical Safety BC jurisdiction, homeowners can apply
for an electrical homeowner permit.
T or F? - (Correct Answer) -T
Shingles should overlap the valley lining by at least ____
a) 12 inches.
b) 6 inches.
c) 2 inches.
d) 5 inches. - (Correct Answer) -b
The moisture trapped within the membranes will form bubbles on the surface
of the flat roof. As moisture builds up on the roof, the bubbles will eventually
grow and pop, forming a blister. The moisture is formed by ___________
a) excessive heat and poor attic ventilation.